Product Highlights

  • Electronic Addressing: Supports in-situ electronic coding and address rewriting via coder.
  • Real-time Data Acquisition: Internal microprocessor acquires and processes temperature data in real-time.
  • Temperature Compensation: Features built-in temperature compensation for accurate detection.
  • Fault Detection: Sensor fault detection with automatic reporting to the control panel.
  • Two-Wire Connection: Non-polarity two-bus connection ensures convenient installation.
  • Remote Indicator Output: Built-in terminal drives external indicator lights during alarms.
  • Low Power Consumption: Standby current is less than 0.3mA for energy efficiency.
  • Dual Alarm Trigger: Detects both smoke and heat to confirm fire alarms accurately.

Product Images of Addressable Smoke and Heat Combined Detector

Addressable Smoke and Heat Combined Detector pictures & photos
Addressable Smoke and Heat Combined Detector
Addressable Smoke and Heat Combined Detector pictures & photos
Addressable Smoke and Heat Combined Detector
Addressable Smoke and Heat Combined Detector pictures & photos
Addressable Smoke and Heat Combined Detector
Addressable Smoke and Heat Combined Detector pictures & photos
Addressable Smoke and Heat Combined Detector
  • Addressable Smoke and Heat Combined Detector
    Addressable Smoke and Heat Combined Detector
  • Addressable Smoke and Heat Combined Detector
    Addressable Smoke and Heat Combined Detector
  • Addressable Smoke and Heat Combined Detector
    Addressable Smoke and Heat Combined Detector
  • Addressable Smoke and Heat Combined Detector
    Addressable Smoke and Heat Combined Detector

Find Similar Products

Product Description

 

Addressable Smoke and Heat Combined Detector



Addressable Smoke and Heat Combined Detector
Addressable Smoke and Heat Combined Detector


Introduction:
AW-D303 Addressable Smoke and Heat Detector is a mated product of the AW-FP300 fire alarm control panel. It uses a two-bus work mode. With an internal microprocessor, it supports electronic coding. The detector realizes real-time acquisition of the in situ temperature data and sends back the data to a fire alarm control panel. It can also receive and execute the control commands given by a fire alarm control panel. When in a routing inspection, the detector indicator will blink. When there is a fire in the monitored area and the temperature has reached the alarm threshold, the fire alarm control panel will confirm a fire
alarm according to the received message sent from the detector, and the detector indicator will light at the same time to indicate a fire alarm.
The detector is suitable for such industrial and civil buildings that have a great deal of heat when fire takes place, such as kitchens, boiler rooms, generator rooms, drying workshops and smoking rooms and is not suitable for places with a great deal of smoke but little heat


Features:
✓ It can realize electronic coding and rewrite the address via coder in situ.
✓ Within a single-chip microcomputer, it can realize real-time data acquisition and processing, realize a curve tracing for the field situation.
✓ It has a temperature compensation function and a sensor fault detection function (fault reporting to fire alarm control panel).
✓ Non-polarity, two-bus connection that ensures convenient installation and maintenance.
✓ Designed with an upper cover and a lower cover and installed on an independent base, it can be installed, debugged and maintained conveniently.
✓ Built-in remote indicator output terminal, drive remote indicator lit when fire alarm


Packaging 
Packaging Details:
1) PEE bag per unit 
2) Outside Cartons
3)Strict & Standard Export Packing Procedures Adopted Exterior Corrugated Hardboard Carton Interior Blister Buffer Staff, Asenware fire pump control equipment.

Shipping

Addressable Smoke and Heat Combined Detector

Company InformationAddressable Smoke and Heat Combined Detector


Addressable Smoke and Heat Combined Detector

Contact Info.


 

     

About the Supplier

This supplier has been audited by CTI. Verify the report on the official CTI website with ID "QIP-ASR242972". Items marked "verified" are certified.

Shenzhen Asenware Test and Control Technology Co., Ltd.
Shenzhen Asenware Test and Control Technology Co., Ltd.
Shenzhen Asenware Test and Control Technology Co., Ltd.
Shenzhen Asenware Test and Control Technology Co., Ltd.
Shenzhen Asenware Test and Control Technology Co., Ltd.
Shenzhen Asenware Test and Control Technology Co., Ltd.
Shenzhen Asenware Test and Control Technology Co., Ltd.
Shenzhen Asenware Test and Control Technology Co., Ltd.

About Our Factory & Business Background

Address
4 / F, 10 Xingye Road, Torch Development Zone, Zhongshan, Guangdong, China
Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment, Money Gram
International Commercial Terms(Incoterms)
FOB, EXW, CIF
Average Lead Time
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays
Nearest Port
Zhongshan

Our Production Capability & Technical Expertise

Main Products
Fire Alarm System, Smoke Detector, Fire Alarm Control Panel, Fire Alarm, FM200, Fire Pump, Flame Detector, Fire Hose Reel, Emergency Light System, Beam Smoke Detector

Our Industry Experience & Global Business Record

Export Year
2005-06-01
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe

FAQ

What is the operating voltage?
The operating voltage is 24V.
Can the address be changed after installation?
Yes, it supports electronic coding and can rewrite the address via a coder in situ.
What is the standby current consumption?
The standby current is less than 0.3mA.
Is the wiring polarity sensitive?
No, it uses a non-polarity two-wire connection.
Where is this detector suitable for use?
It is suitable for areas with high heat like kitchens and boiler rooms, but not for places with heavy smoke and little heat.
Does it support remote indicators?
Yes, it has a built-in remote indicator output terminal that lights up during a fire alarm.
What is the lead time for orders?
The average lead time is within 15 workdays for both peak and off-peak seasons.
What payment methods are accepted?
Accepted payment methods include LC, T/T, D/P, PayPal, Western Union, Small-amount payment, and Money Gram.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now