• Addressable Smoke and Heat Combined Detector
  • Addressable Smoke and Heat Combined Detector
  • Addressable Smoke and Heat Combined Detector
  • Addressable Smoke and Heat Combined Detector

Addressable Smoke and Heat Combined Detector

Type: Smoke Alarm
Signal Transmission: Wired Alarm
Certification: CE, ISO
Application: Indoor
Working Principle: Electro-Optical Type
Transmission Mode: Cable
Customization:
Diamond Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
AW-D303
Operating Voltage
24V
Standby Current
<0.3mA
Alarm Current
<1.5mA (Without Remote Indicator)
Programming
Electronically Addressed
Wiring
Two Wire, Polarity-Insensitive
Transport Package
Cartons
Specification
AW-D303
Trademark
Asenware
Origin
China
Production Capacity
50000PC/Year

Product Description

 

Addressable Smoke and Heat Combined Detector



Addressable Smoke and Heat Combined Detector
Addressable Smoke and Heat Combined Detector


Introduction:
AW-D303 Addressable Smoke and Heat Detector is a mated product of the AW-FP300 fire alarm control panel. It uses a two-bus work mode. With an internal microprocessor, it supports electronic coding. The detector realizes real-time acquisition of the in situ temperature data and sends back the data to a fire alarm control panel. It can also receive and execute the control commands given by a fire alarm control panel. When in a routing inspection, the detector indicator will blink. When there is a fire in the monitored area and the temperature has reached the alarm threshold, the fire alarm control panel will confirm a fire
alarm according to the received message sent from the detector, and the detector indicator will light at the same time to indicate a fire alarm.
The detector is suitable for such industrial and civil buildings that have a great deal of heat when fire takes place, such as kitchens, boiler rooms, generator rooms, drying workshops and smoking rooms and is not suitable for places with a great deal of smoke but little heat


Features:
✓ It can realize electronic coding and rewrite the address via coder in situ.
✓ Within a single-chip microcomputer, it can realize real-time data acquisition and processing, realize a curve tracing for the field situation.
✓ It has a temperature compensation function and a sensor fault detection function (fault reporting to fire alarm control panel).
✓ Non-polarity, two-bus connection that ensures convenient installation and maintenance.
✓ Designed with an upper cover and a lower cover and installed on an independent base, it can be installed, debugged and maintained conveniently.
✓ Built-in remote indicator output terminal, drive remote indicator lit when fire alarm


Packaging 
Packaging Details:
1) PEE bag per unit 
2) Outside Cartons
3)Strict & Standard Export Packing Procedures Adopted Exterior Corrugated Hardboard Carton Interior Blister Buffer Staff, Asenware fire pump control equipment.

Shipping

Addressable Smoke and Heat Combined Detector

Company InformationAddressable Smoke and Heat Combined Detector


Addressable Smoke and Heat Combined Detector

Contact Info.


 

     

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Plant Area
>2000 square meters
Management System Certification
ISO 9001