En Approved Conventional Fire Alarm Smoke Detector (AW-YT102)

Get Latest Price
Min. Order: 100 Pieces
Production Capacity: 2000000 Units/Year
Transport Package: Carton
Payment Terms: L/C, T/T, Western Union, Paypal
Type: Smoke Alarm
Signal Transmission: Wired Alarm
Working Mode: Active
Application: Indoor, Outdoor
Sensor Type: Photoelectric
Working Principle: Electro-Optical Type

You Might Also Like


Basic Info

Model NO.: AW-YT102
Height: 2.2 Inch (55 Mm) Installed in Base
Diameter: 4.0 Inch (103 Mm)
Weight: 5.5 Oz. (155 G)
En Certification: Yes
Is09001 Certificate: Yes
CE Mark: Yes
Trademark: Asenware
Specification: CE, EN54
Origin: Guangdong, China

Product Description

EN and CE Approved Conventional Fire Alarm
Smoke Detector,AW-YT102
En Approved Conventional Fire Alarm Smoke Detector (AW-YT102)
 The device is photoelectronic detector uses a state of-the-art optical sensing chamber. 
This detector is designed
 to provide open area protection and to be used with most
 conventional fire alarm control panel
.Two LEDs on each detector provide local 360
visible alarm indication. They flash every 5 seconds indicating that power is applied and  
the detector is working properly. The
 LEDs latch on in alarm. LEDs will be off when 
a trouble
 condition exists indicating that the detector sensitivity is outside the listed limit.
The alarm can be reset only by a momentary power interruption.

En Approved Conventional Fire Alarm Smoke Detector (AW-YT102)
3. Notify the proper authorities that the system is in operation.
En Approved Conventional Fire Alarm Smoke Detector (AW-YT102)

  Operating Voltage Range:          9 to 28 VDC Volts Non-polarized
  Standby Current:                ≤60µA@24VDC
  Maximum Alarm Current (LED on):    ≤30mA@24VDC
  Operating Humidity Range: 10% to 93% Relative Humidity,
 Non- condensing
  Operating Temperature Range:   -10°C to 50°C (14°F to 122°F)
  Smoke Alarm Sensitivity:        0.15-0.3dB/m
  Height:    55 mm installed in Base
  Diameter:    103 mm
  Weight: 5.5 oz. (155 g)