1-32 Zone Conventional Fire Alarm Panel for Wholesale

Shenzhen Asenware Test and Control Technology Co., Ltd.
  • Audited Supplier
  • 14 yrs

Contact Supplier

Product Highlights

  • EN54 Standard Compliance: Strictly adheres to EN54 part 2&4 standards for safety and reliability.
  • Expandable Zone Design: Modularized design supports extendable zones ranging from 1 to 32.
  • Dual Control Modes: Features two-level control modes with lock functionality for enhanced security.
  • Flexible Power Supply: Provides 24VDC and 5VDC power supply outputs for various devices.
  • Comprehensive Signal Outputs: Includes FIRE & FAULT signal outputs plus 2 general sounder outputs.
  • Advanced Safety Protection: Low-battery protection automatically cuts off power below 21VDC until mains is restored.
  • Optional GSM Module: GSM module for SMS fire alarm notification is available as an optional feature.
  • User-Friendly Maintenance: Economic design with convenient maintenance and dedicated RESET/SILENCE/EVACUATE buttons.

Product Images of 1-32 Zone Conventional Fire Alarm Panel for Wholesale

1-32 Zone Conventional Fire Alarm Panel for Wholesale
1-32 Zone Conventional Fire Alarm Panel for Wholesale pictures & photos
1-32 Zone Conventional Fire Alarm Panel for Wholesale
1-32 Zone Conventional Fire Alarm Panel for Wholesale pictures & photos
1-32 Zone Conventional Fire Alarm Panel for Wholesale
1-32 Zone Conventional Fire Alarm Panel for Wholesale pictures & photos
1-32 Zone Conventional Fire Alarm Panel for Wholesale
1-32 Zone Conventional Fire Alarm Panel for Wholesale pictures & photos
1-32 Zone Conventional Fire Alarm Panel for Wholesale
1-32 Zone Conventional Fire Alarm Panel for Wholesale pictures & photos
1-32 Zone Conventional Fire Alarm Panel for Wholesale
  • 1-32 Zone Conventional Fire Alarm Panel for Wholesale
  • 1-32 Zone Conventional Fire Alarm Panel for Wholesale
    1-32 Zone Conventional Fire Alarm Panel for Wholesale
  • 1-32 Zone Conventional Fire Alarm Panel for Wholesale
    1-32 Zone Conventional Fire Alarm Panel for Wholesale
  • 1-32 Zone Conventional Fire Alarm Panel for Wholesale
    1-32 Zone Conventional Fire Alarm Panel for Wholesale
  • 1-32 Zone Conventional Fire Alarm Panel for Wholesale
    1-32 Zone Conventional Fire Alarm Panel for Wholesale
  • 1-32 Zone Conventional Fire Alarm Panel for Wholesale
    1-32 Zone Conventional Fire Alarm Panel for Wholesale

Find Similar Products

Product Description

1-32 Zone conventional fire alarm panel

Introduce:

1. Strictly in accordance with the EN54 part 2&4 standard.
2. Modularized design with extendable zones from 1 to 32 zones.
3. With two-level control modes by lock
4. 24VDC & 5VDC power supply outputs.
5. FIRE &  FAULT signal outputs.
6. Owns 2 general sounders outputs.
7. Each zone has 1 circuit detectors input .
8. Each zone can be disable by a button.
9. RESET button available
10.SILENCE button to stop BUZZER and SOUNDERS.
11. EVACUATE button to start a manual fire alarm immediately.
12.Low-battery level protection function, i.e., battery voltage lower than 21VDC, battery will be cut off automatically until the mains power is on.
13.GSM module for fire alarm by SMS is optional.
14 Economic, user-friendly & convenient maintenance.

1-32 Zone Conventional Fire Alarm Panel for Wholesale
1-32 Zone Conventional Fire Alarm Panel for Wholesale


Packaging & Shipping

As the pics shows:
1-32 Zone Conventional Fire Alarm Panel for Wholesale


Parameters
 
ITEM 1Zone panel 2Zone panel 4-8 Zone panel 12-32 Zone panel
Model No. AW-CFP2166-01 AW-CFP2166-02 AW-CFP2166-04-8 AW-CFP2166-12-32
Power specification
 
Mains supply voltage 110VAC or 240VAC
Internal power supply 27.2VDC
Total output current limited 500mA @ 240VAC 500mA @ 240VAC 3A @ 240VAC 3A @ 240VAC
Main supply monitor for fault Yes
Battery protection for low voltage Yes
Batteries (default configuration) 12V2AH*2
Detector circuit specification
 
Number of circuit 1 2 4-16 4-32
Line fault monitor for open circuit Yes
Line fault monitor for short circuit Yes
Line fault monitor for detector removal Yes, if End of Line Monitor Unit fitted in place of End of Line Resistor
End of Line device 6.8k Ω,5% tolerance, 0.25W (colour code-blue,grey,red,gold)
Detector continuity diodes Silicon 1N4001 or Schottky type (required if End of Line Monitor Unit fitted to give Detector Removal Fault)
Call point resistor value 470 to 680 Ω, 0.225 or 0.5 watt
Maximum number of smoke/heat detectors per zone 20 (based on a total detector current of 2mA, each detector consuming 100μA).Note: if End of Line Monitor Unit is fitted, for correct operation maxmum voltage drop must not exceed 12 volts.
Maximum number of manual call points per zone No limit
Sounder circuit specification
 
Number of general circuits 2
End of line resistor value 6.8k Ω,5% tolerance, 0.25W (colour code-blue,grey,red,gold)
Line fault monitor for open circuit Yes
Line fault monitor for short circuit Yes
Outputs fused AT 400mA
Maximum number of bells @ 20mA of each sounder output 20
Fuses
 
Battery fuse 1.5A F 20mm
Sounder outputs 500mA F 20mm
Fire and fault output
 
Output type NC and NO relay
Maximum current 100mA
Connection block
 
Largest acceptable conductor size 2.5mm2
Smallest acceptable conductor size 0.75mm2
Size and weight
 

 
Dimensions(mm) 272*200*70mm 320*231*90mm 395X502X124 362X565X124
Weight (without batteries) 4kg 5kg 7kg 8kg
Weight (with batteries) 5.8kg 6.8kg 9.6kg 12.5kg

Company Information

Asenware,manufacturer of fire alarm and fire suppression system since 2005. 
Our headquarter is in London, UK, with factory Shenzhen, China.

We keep our best service for our customers, and have a rich experienced engineer team to design and install 
for overseas project.


Product range

Addressable fire alarm system
Conventional fire alarm system (2166 series)
FM200 gas suppression system (2159 series)
Fire pump
Fire hose/ hose reel and cabinet
ABC powder/ CO2 fire extinguisher
Emergency light system

1-32 Zone Conventional Fire Alarm Panel for Wholesale
Certificates

1-32 Zone Conventional Fire Alarm Panel for Wholesale

Contact





 

About the Supplier

This supplier has been audited by CTI. Verify the report on the official CTI website with ID "QIP-ASR242972". Items marked "verified" are certified.

Shenzhen Asenware Test and Control Technology Co., Ltd.
Shenzhen Asenware Test and Control Technology Co., Ltd.
Shenzhen Asenware Test and Control Technology Co., Ltd.
Shenzhen Asenware Test and Control Technology Co., Ltd.
Shenzhen Asenware Test and Control Technology Co., Ltd.
Shenzhen Asenware Test and Control Technology Co., Ltd.
Shenzhen Asenware Test and Control Technology Co., Ltd.
Shenzhen Asenware Test and Control Technology Co., Ltd.

About Our Factory & Business Background

Address
4 / F, 10 Xingye Road, Torch Development Zone, Zhongshan, Guangdong, China
Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment, Money Gram
International Commercial Terms(Incoterms)
FOB, EXW, CIF
Average Lead Time
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays
Nearest Port
Zhongshan

Our Production Capability & Technical Expertise

Main Products
Fire Alarm System, Smoke Detector, Fire Alarm Control Panel, Fire Alarm, FM200, Fire Pump, Flame Detector, Fire Hose Reel, Emergency Light System, Beam Smoke Detector

Our Industry Experience & Global Business Record

Export Year
2005-06-01
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe

FAQ

What is the maximum number of zones supported?
The panel features a modularized design with extendable zones from 1 to 32.
Does this panel meet international safety standards?
Yes, it is strictly in accordance with the EN54 part 2&4 standard.
What power supply options are available?
It supports 110VAC or 240VAC mains supply with 24VDC and 5VDC output capabilities.
Can the system send SMS alerts for fires?
Yes, a GSM module for fire alarm by SMS is available as an optional feature.
How many detectors can be connected per zone?
The maximum number of smoke or heat detectors per zone is 20.
What happens if the battery voltage is too low?
The system has low-battery protection that cuts off the battery if voltage drops below 21VDC.
Is the lead time affected by the season?
No, the lead time is within 15 workdays for both peak and off-peak seasons.
What payment methods are accepted?
We accept LC, T/T, D/P, PayPal, Western Union, Small-amount payment, and Money Gram.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now