Lpcb Approved Addressable Fire Alarm System 32 Zone Control Panel

Shenzhen Asenware Test and Control Technology Co., Ltd.
  • Audited Supplier
  • 14 yrs

Contact Supplier

Product Images of Lpcb Approved Addressable Fire Alarm System 32 Zone Control Panel

Lpcb Approved Addressable Fire Alarm System 32 Zone Control Panel pictures & photos
Lpcb Approved Addressable Fire Alarm System 32 Zone Control Panel
Lpcb Approved Addressable Fire Alarm System 32 Zone Control Panel pictures & photos
Lpcb Approved Addressable Fire Alarm System 32 Zone Control Panel
  • Lpcb Approved Addressable Fire Alarm System 32 Zone Control Panel
    Lpcb Approved Addressable Fire Alarm System 32 Zone Control Panel
  • Lpcb Approved Addressable Fire Alarm System 32 Zone Control Panel
    Lpcb Approved Addressable Fire Alarm System 32 Zone Control Panel

Find Similar Products

Product Description

LPCB Approved Addressable fire alarm system 32 zone control panel
Lpcb Approved Addressable Fire Alarm System 32 Zone Control Panel

Introduction:
The purpose of the AW-FP300Fire Alarm Control Panel (FACP) is to monitor input signals, give indications and possibly activate outputs as programmed. It is designed to comply with EN 54-2 with qualities of simple installation, operation and easy maintenance. 
The AW-FP300panel is an addressable fire detection panel with 1 loop of 324 addressable points and expansion capabilities.It is compatible with other peripherals made by ASENWARE with its own protocol.

Features:
The AW-FP300 single loop 32 zone fire alarm control panel offers the following features: 
1. Up to 324 addresses on one loop
2. An easy to read, 4.3'' color screen LCD with a resolution of 480×272
3. Zone indication and control panel(ZCP) for 32 zones gives a quick indication of the location of an alarm
4. Record capacity of 1000 historical events for each of historical fire, historical fault and historical operation
5. An independently programmable conventional sounder circuit output
6. Integral power supply and battery
7. Integral printer
8. Flexible and intuitive cause and effect programming on front panel
9. Zone test, point test and module start/stop testing facilitate the commissioning
10. U-disk interface makes the load and save of configuration or historical data convenient for system commissioning and maintenance
11. Hierarchy management with three access levels 
12. Anti-tamper protection by a key lock
13. CAN bus for interconnection of up to 20 FACPs and RS485 for connection with up to 30 fire indicating panels per FACP

Parameters:
 Power supply 
Mains supply  230VAC (-15%, +10%). 47 ~ 63Hz. Max current 0.8A 
Mains fuse  T3.15AL250V 
Operating voltage  18.5 ~ 30VDC 
Recommended mains cable  Screened or standard/black mains cable, cable size 0.75mm2 
Power rating  Imax.a=1.2A; Imax.b=2.6A; Imin=0.65A 
Max. charging current  1.2A 
Max. battery supply current  4A (when the Mains is disconnected) 
Battery capacity, type and recommended model  Max. capacity 2×12V/17Ah; Min. capacity 2×12V/12Ah 
VRLA. PS-12170 for 17Ah (Power-sonic), PS12120 for 12Ah (Power-sonic) 
Max. internal resistance of battery  1.5Ω
Battery fuse  F8AL250V 
Recommended battery cable  14AWG 
Quiescent current (full loaded)  < 0.4A 
Outputs 
S.C. Out (+, -)  Output voltage  18.5 ~ 30VDC 
Max. output current  0.5A 
Fuse rating  F1AL250V 
End of line resistor  4K7 
Recommended type of cable  Plain unscreened cable, 1.5mm2 
Cable diameter  1mm2 ~2mm2 
Transmission distance  ≤1500m 
Max. number of sounders @50mA  20 
F.P.E. Out (+, -) 
F.A. Out (+, -) 
Output voltage  18.5 ~ 30VDC 
Max. output current  0.5A 
Fuse rating  F1AL250V 
End of line resistor  4K7 
Recommended type of cable  Plain unscreened cable, 1.5mm2 
Cable diameter  1mm2 ~2mm2 
Transmission distance  ≤1500m 
Fault Out 
(NC, COM, NO) 
Contact capacity  30VDC@2A, [email protected] 
Recommended type of cable  Plain unscreened cable, 1.5mm2 
Cable diameter  1mm2 ~ 2mm2 
24VK (+, -)  Output voltage  18.5 ~ 30VDC 
Max. output current  0.6A 
Fuse rating  F1AL250V 
Recommended type of cable  Plain unscreened cable, 1.5mm2 
Cable diameter  1mm2 ~2mm2 
Input 
Class change (+, -)  Input mode  Passive 
Cable resistance  ≤500Ω
Recommended type of cable  Plain unscreened cable, 1.5mm2 
Cable diameter  1mm2 ~2mm2 
Loop 
Loop Out (+, -) 
Loop In (+, -) 
Output voltage  16.5 ~ 30VDC, pulse 
Output current  0 ~0.3A 
Loop type  Class A 
Recommended type of cable  Screened or unscreened twisted-pair, 1.5mm2 
Transmission distance  ≤1000m 
Cable diameter  1mm2 ~2mm2 
Network communication 
RS-485  Max. number of FIPs  30 
Transmission rate  9600 bps 
Recommended type of cable  Screened or unscreened twisted-pair, 1mm2 
Transmission distance  ≤1000m 
Cable diameter  1mm2 ~5mm2 
CAN  Max. number of panels  20 
Transmission rate  Optional: 10K, 20K, 50K and 100K bps 
Recommended type of cable  Screened or unscreened twisted-pair, 1mm2 
Transmission distance  ≤1000m 
Cable diameter  1mm2 ~5mm2 
Physical dimensions 
Approx. Dimensions of the panel (W×H×D)  430×560×170mm 
Approx. weight (without battery)  14kg 
Operating conditions 
Temperature range: 0°C~45°C; Max relative humidity: 95% (40°C ±2°C, no condensation) 


Packaging & Shipping
Packaging Details:
1) PEE bag per unit 
2) Outside Cartons
3)Strict & Standard Export Packing Procedures Adopted Exterior Corrugated Hardboard Carton Interior Blister Buffer Staff, Asenware fire pump control equipment.
Lpcb Approved Addressable Fire Alarm System 32 Zone Control Panel


Our company
Asenware, manufacturer of fire alarm and fire suppression system since 2005. Our headquarter is in London, UK, with factory Shenzhen, China
We keep our best service for our customers, and have a rich experienced engineer team to design and install for overseas projects.

Contact us
Asenware Ltd

Address:701, Bd 8, Dongfangming Industry Zone, Dabao Rd., Baoan, Shenzhen, China, Zip Code :518101
Phone number: +86(0) 0755-27663815
 
Company website: http://asenware.en.made-in-china.com

Product range
1. Addressable fire alarm system(FP100 series,2189,2100 series)
2. Conventional fire alarm system(2166 series)
3. FM200 gas fire suppression system
4. Emergency light system
5. Fire pump system
6. Fire hose and fire hose reel cabinet

Our Services
1.OEM / ODM services.
2.Professional technical team.
3.Offer Free technical support whenever you need
4.Two year warranty and technical maintenance

FAQ 
Q1: Are you manufacturer?
A: (yes)
Q2: What is the lead time?
A: usually
Fire control: one week working day
bulk quality: three weeks working days
Emergency lights: two weeks working days
bulk quality: four weeks
FM200:  two weeks working day
Fire pump: 25 days
Q3: How do you ship the goods and how long does it take arrive?
A: We usually ship by DHL, UPS, FedEx or by Air. 3-5 days after payment received.
Q4: Can I have a sample order?
A:Yes,we welcome sample order to test and check quality.
Q5: Do you offer OEM service?
A: Yes, we can design the things according to your request.

About the Supplier

This supplier has been audited by CTI. Verify the report on the official CTI website with ID "QIP-ASR242972". Items marked "verified" are certified.

Shenzhen Asenware Test and Control Technology Co., Ltd.
Shenzhen Asenware Test and Control Technology Co., Ltd.
Shenzhen Asenware Test and Control Technology Co., Ltd.
Shenzhen Asenware Test and Control Technology Co., Ltd.
Shenzhen Asenware Test and Control Technology Co., Ltd.
Shenzhen Asenware Test and Control Technology Co., Ltd.
Shenzhen Asenware Test and Control Technology Co., Ltd.
Shenzhen Asenware Test and Control Technology Co., Ltd.

About Our Factory & Business Background

Address
4 / F, 10 Xingye Road, Torch Development Zone, Zhongshan, Guangdong, China
Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment, Money Gram
International Commercial Terms(Incoterms)
FOB, EXW, CIF
Average Lead Time
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays
Nearest Port
Zhongshan

Our Production Capability & Technical Expertise

Main Products
Fire Alarm System, Smoke Detector, Fire Alarm Control Panel, Fire Alarm, FM200, Fire Pump, Flame Detector, Fire Hose Reel, Emergency Light System, Beam Smoke Detector

Our Industry Experience & Global Business Record

Export Year
2005-06-01
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now