Asenware En54 Lpcb Reflective Beam Detectors

Shenzhen Asenware Test and Control Technology Co., Ltd.
  • Audited Supplier
  • 14 yrs

Contact Supplier

Product Highlights

  • EN54 LPCB Certified: Complies with EN54 standards for reliable fire detection.
  • Wide Monitoring Range: Available in 25m, 40m, 70m, and 100m distances with optional reflectors.
  • All-in-One Design: Emitter and receiver combined for easy installation and collimation.
  • Automatic Calibration: Allows single-person debugging and ensures optical path accuracy.
  • Self-Testing Function: Monitors internal faults to ensure continuous device reliability.
  • Anti-Dust Compensation: Automatically compensates for dust pollution and signal aging.
  • Waterproof & Anti-Corrosion: Sealed design ensures reliability in harsh environments.

Product Images of Asenware En54 Lpcb Reflective Beam Detectors

Asenware En54 Lpcb Reflective Beam Detectors pictures & photos
Asenware En54 Lpcb Reflective Beam Detectors
Asenware En54 Lpcb Reflective Beam Detectors pictures & photos
Asenware En54 Lpcb Reflective Beam Detectors
Asenware En54 Lpcb Reflective Beam Detectors pictures & photos
Asenware En54 Lpcb Reflective Beam Detectors
Asenware En54 Lpcb Reflective Beam Detectors pictures & photos
Asenware En54 Lpcb Reflective Beam Detectors
  • Asenware En54 Lpcb Reflective Beam Detectors
    Asenware En54 Lpcb Reflective Beam Detectors
  • Asenware En54 Lpcb Reflective Beam Detectors
    Asenware En54 Lpcb Reflective Beam Detectors
  • Asenware En54 Lpcb Reflective Beam Detectors
    Asenware En54 Lpcb Reflective Beam Detectors
  • Asenware En54 Lpcb Reflective Beam Detectors
    Asenware En54 Lpcb Reflective Beam Detectors

Find Similar Products

Product Description

Asenware EN54 LPCB Reflective Beam Detectors

Asenware En54 Lpcb Reflective Beam Detectors
Introduction:
The AW-BK901 infrared linear reflex beam smoke detector, being designed for fire prevention in the open area, is a long interval one and used with the fire alarm controller. The detector is made up of the combination unit of the emitter and the receiver as well as the reflecting mirror. The signal issued by the emitter enters into the receiver after reflection by t
he reflector.

1. Unit the emitter and the receiver as one. In that case, it has advantages of easy and convenient installation as well as wonderful collimation for the optical path.
2. Automatic calibration to make sure one person can debug the device easily.
3. Self-testing function of to monitor the internal fault of the detector.
4. Automatic compensation for the factors of t h e receiving signals to avoid the influence of dust pollution, positional deviation and aging of transmitter tubes.
5. The detector is designed for optical path, strong antijamming capability, seal design and reliable anti-corrosion and water-proof.

Power supply voltage 16V~28VDC
Debug current ≤20mA
Monitoring current ≤12mA
Alarm current ≤22mA
Overall power consumption <3W
Use conditions Temperature: -10°C~+50°C
Relative humidity ≤ 95%
Protective area The maximum protective area of the detector is 1400 m² (14×100=1400 m²) and the maximum width is 14m.
Optional Monitoring Distance AW-BK901-25 25meters with 1 reflector
AW-BK901-40 40meters with 1 reflector
AW-BK901-70 70meters with 4 reflector
AW-BK901-100 100meters with 4 reflectorS

Our company
Asenware, manufacturer of fire alarm and fire suppression system since 2005. Our headquarter is in London, UK, with factory Shenzhen, China
We keep our best service for our customers, and have a rich experienced engineer team to design and install for overseas projects.

Product range:

1. Addressable fire alarm system(FP100 series,2189,2100 series)
2. Conventional fire alarm system(2166 series)
3. FM200 gas fire suppression system

Asenware En54 Lpcb Reflective Beam Detectors



Contact us


Shenzhen Asenware Test And Control Technology Co.,Ltd.

Address: Room 701,Bd8,Dongfangming industry zone,Dabao Rd, Baoan, Shenzhen,China-518101
Mobile:+86-136-3251-2808
 
 
Website:asenware.en.made-in-china.com 

About the Supplier

This supplier has been audited by CTI. Verify the report on the official CTI website with ID "QIP-ASR242972". Items marked "verified" are certified.

Shenzhen Asenware Test and Control Technology Co., Ltd.
Shenzhen Asenware Test and Control Technology Co., Ltd.
Shenzhen Asenware Test and Control Technology Co., Ltd.
Shenzhen Asenware Test and Control Technology Co., Ltd.
Shenzhen Asenware Test and Control Technology Co., Ltd.
Shenzhen Asenware Test and Control Technology Co., Ltd.
Shenzhen Asenware Test and Control Technology Co., Ltd.
Shenzhen Asenware Test and Control Technology Co., Ltd.

About Our Factory & Business Background

Address
4 / F, 10 Xingye Road, Torch Development Zone, Zhongshan, Guangdong, China
Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment, Money Gram
International Commercial Terms(Incoterms)
FOB, EXW, CIF
Average Lead Time
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays
Nearest Port
Zhongshan

Our Production Capability & Technical Expertise

Main Products
Fire Alarm System, Smoke Detector, Fire Alarm Control Panel, Fire Alarm, FM200, Fire Pump, Flame Detector, Fire Hose Reel, Emergency Light System, Beam Smoke Detector

Our Industry Experience & Global Business Record

Export Year
2005-06-01
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe

FAQ

What is the monitoring distance range?
The detector supports distances of 25m, 40m, 70m, and 100m depending on the model and number of reflectors used.
What is the maximum coverage area?
The maximum protective area is 1400 square meters with a maximum width of 14 meters.
Does the detector require manual calibration?
No, it features automatic calibration allowing one person to easily debug the device.
What is the power supply requirement?
The device operates on a DC voltage of 16V to 28V.
Is the detector suitable for outdoor use?
Yes, it has a waterproof and anti-corrosion seal design suitable for various environments.
How does the detector handle dust and aging?
It includes automatic compensation for dust pollution, positional deviation, and transmitter tube aging.
What is the lead time for orders?
The average lead time is within 15 working days for both peak and off-peak seasons.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now