Aw-D106 Asenware Addressable Alarm Fire Strobe Sounder

Shenzhen Asenware Test and Control Technology Co., Ltd.
  • Audited Supplier
  • 14 yrs

Contact Supplier

Product Highlights

  • High Volume Alarm: Delivers a powerful sound level of 100dB or higher for effective warning.
  • Dual Wiring Options: Supports both two-wire and four-wire system wiring methods for flexibility.
  • Wide Voltage Range: Operates reliably on 18V-28V DC power supply.
  • Fast Flash Response: Features a flash period of less than or equal to 1.0 second.
  • Established Manufacturer: Produced by Asenware, a manufacturer with over 15 years of experience since 2005.
  • Global Support Team: Backed by experienced engineers for design and installation support.
  • No Polarization Required: Main line end receives two main lines without polarization constraints.

Product Images of Aw-D106 Asenware Addressable Alarm Fire Strobe Sounder

Aw-D106 Asenware Addressable Alarm Fire Strobe Sounder pictures & photos
Aw-D106 Asenware Addressable Alarm Fire Strobe Sounder
Aw-D106 Asenware Addressable Alarm Fire Strobe Sounder pictures & photos
Aw-D106 Asenware Addressable Alarm Fire Strobe Sounder
Aw-D106 Asenware Addressable Alarm Fire Strobe Sounder pictures & photos
Aw-D106 Asenware Addressable Alarm Fire Strobe Sounder
Aw-D106 Asenware Addressable Alarm Fire Strobe Sounder pictures & photos
Aw-D106 Asenware Addressable Alarm Fire Strobe Sounder
Aw-D106 Asenware Addressable Alarm Fire Strobe Sounder pictures & photos
Aw-D106 Asenware Addressable Alarm Fire Strobe Sounder
  • Aw-D106 Asenware Addressable Alarm Fire Strobe Sounder
    Aw-D106 Asenware Addressable Alarm Fire Strobe Sounder
  • Aw-D106 Asenware Addressable Alarm Fire Strobe Sounder
    Aw-D106 Asenware Addressable Alarm Fire Strobe Sounder
  • Aw-D106 Asenware Addressable Alarm Fire Strobe Sounder
    Aw-D106 Asenware Addressable Alarm Fire Strobe Sounder
  • Aw-D106 Asenware Addressable Alarm Fire Strobe Sounder
    Aw-D106 Asenware Addressable Alarm Fire Strobe Sounder
  • Aw-D106 Asenware Addressable Alarm Fire Strobe Sounder
    Aw-D106 Asenware Addressable Alarm Fire Strobe Sounder

Find Similar Products

Product Description

AW-D106 Asenware Addressable Strobe Sounder

Aw-D106 Asenware Addressable Alarm Fire Strobe Sounder

Introduction:

AW-D106 Addressable Fire Strobe Sounder is a kind of terminal device for alarm; it 
is used for the sound and light alarm when the fire happens.

1. Adopt the two-wire or the four-wire system wiring method
2. The main line end receives two main lines, No polarization
3. Connect the power end to DC24V power line.

Model No. AW-D106
Operating Voltage 18V-28V DC  
Work Current 10-60mA
Alarm SPL ≥100dB
Flash Period ≤1.0S
Temperature -10ºC~50ºC

Our company
Asenware, manufacturer of fire alarm and fire suppression system since 2005. Our headquarter is in London, UK, with factory Shenzhen, China
We keep our best service for our customers, and have a rich experienced engineer team to design and install for overseas projects.

Product range:
1. Addressable fire alarm system(FP100 series,2189,2100 series)
2. Conventional fire alarm system(2166 series)
3. FM200 gas fire suppression system
4. Emergency light system
5. Fire pump system
6. Fire hose and fire hose reel cabinet

Aw-D106 Asenware Addressable Alarm Fire Strobe Sounder
Aw-D106 Asenware Addressable Alarm Fire Strobe SounderAw-D106 Asenware Addressable Alarm Fire Strobe Sounder

Contact us
Asenware Ltd
 
Address:701, Bd 8, Dongfangming Industry Zone, Dabao Rd., Baoan, Shenzhen, China, Zip Code :518101
 

Company website: http://asenware.en.made-in-china.com

About the Supplier

This supplier has been audited by CTI. Verify the report on the official CTI website with ID "QIP-ASR242972". Items marked "verified" are certified.

Shenzhen Asenware Test and Control Technology Co., Ltd.
Shenzhen Asenware Test and Control Technology Co., Ltd.
Shenzhen Asenware Test and Control Technology Co., Ltd.
Shenzhen Asenware Test and Control Technology Co., Ltd.
Shenzhen Asenware Test and Control Technology Co., Ltd.
Shenzhen Asenware Test and Control Technology Co., Ltd.
Shenzhen Asenware Test and Control Technology Co., Ltd.
Shenzhen Asenware Test and Control Technology Co., Ltd.

About Our Factory & Business Background

Address
4 / F, 10 Xingye Road, Torch Development Zone, Zhongshan, Guangdong, China
Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment, Money Gram
International Commercial Terms(Incoterms)
FOB, EXW, CIF
Average Lead Time
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays
Nearest Port
Zhongshan

Our Production Capability & Technical Expertise

Main Products
Fire Alarm System, Smoke Detector, Fire Alarm Control Panel, Fire Alarm, FM200, Fire Pump, Flame Detector, Fire Hose Reel, Emergency Light System, Beam Smoke Detector

Our Industry Experience & Global Business Record

Export Year
2005-06-01
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe

FAQ

What is the operating voltage range?
The device operates on a DC voltage range of 18V to 28V.
Does the device support polarization?
No, the main line end receives two main lines without polarization.
What wiring methods are supported?
It supports both two-wire and four-wire system wiring methods.
What is the alarm sound level?
The alarm SPL is greater than or equal to 100dB.
What is the flash period of the strobe?
The flash period is less than or equal to 1.0 second.
What is the work current consumption?
The work current is between 10mA and 60mA.
Who manufactures this product?
It is manufactured by Asenware, a company established in 2005.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now