  • Modular Zone Expansion: Easily expands from 1 to 32 zones with modular design.
  • EN54 Compliance: Designed based on EN54 part 2&4 standards for safety.
  • Dual Control Modes: Features 2-level control mode accessible via a lock.
  • Comprehensive Signal Outputs: Provides FIRE, FAULT, and 2 general sounder outputs.
  • Battery Protection: Auto-cuts off battery when voltage drops below 21VDC.
  • Optional GSM Module: Supports optional GSM module for SMS fire alarms.
  • User-Friendly Operation: Includes RESET, SILENCE, and EVACUATE buttons.
  • Fast Delivery: Delivery time is within 15 working days.

Product Images of Good Price Conventional Fire Alarm Control Panel 1/2/4/8/12/16/20/24/28/32 Zone

Good Price Conventional Fire Alarm Control Panel 1/2/4/8/12/16/20/24/28/32 Zone
Good Price Conventional Fire Alarm Control Panel 1/2/4/8/12/16/20/24/28/32 Zone pictures & photos
Good Price Conventional Fire Alarm Control Panel 1/2/4/8/12/16/20/24/28/32 Zone
Good Price Conventional Fire Alarm Control Panel 1/2/4/8/12/16/20/24/28/32 Zone pictures & photos
Good Price Conventional Fire Alarm Control Panel 1/2/4/8/12/16/20/24/28/32 Zone
Good Price Conventional Fire Alarm Control Panel 1/2/4/8/12/16/20/24/28/32 Zone pictures & photos
Good Price Conventional Fire Alarm Control Panel 1/2/4/8/12/16/20/24/28/32 Zone
Good Price Conventional Fire Alarm Control Panel 1/2/4/8/12/16/20/24/28/32 Zone pictures & photos
Good Price Conventional Fire Alarm Control Panel 1/2/4/8/12/16/20/24/28/32 Zone
Good Price Conventional Fire Alarm Control Panel 1/2/4/8/12/16/20/24/28/32 Zone pictures & photos
Good Price Conventional Fire Alarm Control Panel 1/2/4/8/12/16/20/24/28/32 Zone
Good Price Conventional Fire Alarm Control Panel 1/2/4/8/12/16/20/24/28/32 Zone pictures & photos
Good Price Conventional Fire Alarm Control Panel 1/2/4/8/12/16/20/24/28/32 Zone
  • Good Price Conventional Fire Alarm Control Panel 1/2/4/8/12/16/20/24/28/32 Zone
  • Good Price Conventional Fire Alarm Control Panel 1/2/4/8/12/16/20/24/28/32 Zone
    Good Price Conventional Fire Alarm Control Panel 1/2/4/8/12/16/20/24/28/32 Zone
  • Good Price Conventional Fire Alarm Control Panel 1/2/4/8/12/16/20/24/28/32 Zone
    Good Price Conventional Fire Alarm Control Panel 1/2/4/8/12/16/20/24/28/32 Zone
  • Good Price Conventional Fire Alarm Control Panel 1/2/4/8/12/16/20/24/28/32 Zone
    Good Price Conventional Fire Alarm Control Panel 1/2/4/8/12/16/20/24/28/32 Zone
  • Good Price Conventional Fire Alarm Control Panel 1/2/4/8/12/16/20/24/28/32 Zone
    Good Price Conventional Fire Alarm Control Panel 1/2/4/8/12/16/20/24/28/32 Zone
  • Good Price Conventional Fire Alarm Control Panel 1/2/4/8/12/16/20/24/28/32 Zone
    Good Price Conventional Fire Alarm Control Panel 1/2/4/8/12/16/20/24/28/32 Zone
  • Good Price Conventional Fire Alarm Control Panel 1/2/4/8/12/16/20/24/28/32 Zone
    Good Price Conventional Fire Alarm Control Panel 1/2/4/8/12/16/20/24/28/32 Zone

Find Similar Products

Product Description

1-32 zone conventional fire detection control panel

Introduction:

The AW-CFP2166 series conventional fire alarm panel is designed based on EN54 part 2&4 standard. And it is the central part of conventional fire alarm system, designed for applications requiring smoke detector, bell, manual pull stations, and sprinkler supervision. Each zone can be disabled by a button. The basic unit offers 1 to 8 zones of initiation, up to 16 zones for larger applications.
Good Price Conventional Fire Alarm Control Panel 1/2/4/8/12/16/20/24/28/32 Zone



1 AW-CFP2166 series conventional fire alarm panel is designed based on EN54 part 2&4 standard.
2 It is modularized design, the panel can expend from 1 zone to 32 zones easily.
3 It has 2 level control mode by a lock
4 It has 24VDC and 5VDC power supply output.
5 It has FIRE and FAULT signal output.
6 It has 2 general sounders output.
7 Each zone has 1 circuit detectors input.
8 Each zone can be disable by a button.
9 It has RESET button to reset the panel.
10 It has SILENCE button to stop BUZZER and SOUNDERS.
11 It has EVACUATE button to start a manual fire alarm immediately.
12 It has battery low protection function, when battery voltage lower than 21VDC, battery will be cut off automatically until the mains power is on.
13 It has an optional GSM module for fire alarm by SMS.
14 It is economic, user-friendly and easy maintenance.
Good Price Conventional Fire Alarm Control Panel 1/2/4/8/12/16/20/24/28/32 Zone

Parameters:
ITEM 1Zone panel 2Zone panel 4-8 Zone panel 12-32 Zone panel
Model No. AW-CFP2166-01 AW-CFP2166-02 AW-CFP2166-04-8 AW-CFP2166-12-32
Power specification
 
Mains supply voltage 110VAC or 240VAC
Internal power supply 27.2VDC
Total output current limited 500mA @ 240VAC 500mA @ 240VAC 3A @ 240VAC 3A @ 240VAC
Main supply monitor for fault Yes
Battery protection for low voltage Yes
Batteries (default configuration) 12V2AH*2
Detector circuit specification
 
Number of circuit 1 2 4-16 4-32
Line fault monitor for open circuit Yes
Line fault monitor for short circuit Yes
Line fault monitor for detector removal Yes, if End of Line Monitor Unit fitted in place of End of Line Resistor
End of Line device 6.8k Ω,5% tolerance, 0.25W (colour code-blue,grey,red,gold)
Detector continuity diodes Silicon 1N4001 or Schottky type (required if End of Line Monitor Unit fitted to give Detector Removal Fault)
Call point resistor value 470 to 680 Ω, 0.225 or 0.5 watt
Maximum number of smoke/heat detectors per zone 20 (based on a total detector current of 2mA, each detector consuming 100μA).Note: if End of Line Monitor Unit is fitted, for correct operation maxmum voltage drop must not exceed 12 volts.
Maximum number of manual call points per zone No limit
Sounder circuit specification
 
Number of general circuits 2
End of line resistor value 6.8k Ω,5% tolerance, 0.25W (colour code-blue,grey,red,gold)
Line fault monitor for open circuit Yes
Line fault monitor for short circuit Yes
Outputs fused AT 400mA
Maximum number of bells @ 20mA of each sounder output 20
Fuses
 
Battery fuse 1.5A F 20mm
Sounder outputs 500mA F 20mm
Fire and fault output
 
Output type NC and NO relay
Maximum current 100mA
Connection block
 
Largest acceptable conductor size 2.5mm2
Smallest acceptable conductor size 0.75mm2
Size and weight
 

 
Dimensions(mm) 272*200*70mm 320*231*90mm 395X502X124 362X565X124
Weight (without batteries) 4kg 5kg 7kg 8kg
Weight (with batteries) 5.8kg 6.8kg 9.6kg 12.5kg

Show board for conventional fire alarm system

Good Price Conventional Fire Alarm Control Panel 1/2/4/8/12/16/20/24/28/32 Zone
Good Price Conventional Fire Alarm Control Panel 1/2/4/8/12/16/20/24/28/32 Zone

Company
Good Price Conventional Fire Alarm Control Panel 1/2/4/8/12/16/20/24/28/32 Zone



Good Price Conventional Fire Alarm Control Panel 1/2/4/8/12/16/20/24/28/32 Zone



Contact us

Swing
 
 
 
 
 
 
 
 

About the Supplier

This supplier has been audited by CTI. Verify the report on the official CTI website with ID "QIP-ASR242972". Items marked "verified" are certified.

Shenzhen Asenware Test and Control Technology Co., Ltd.
Shenzhen Asenware Test and Control Technology Co., Ltd.
Shenzhen Asenware Test and Control Technology Co., Ltd.
Shenzhen Asenware Test and Control Technology Co., Ltd.
Shenzhen Asenware Test and Control Technology Co., Ltd.
Shenzhen Asenware Test and Control Technology Co., Ltd.
Shenzhen Asenware Test and Control Technology Co., Ltd.
Shenzhen Asenware Test and Control Technology Co., Ltd.

About Our Factory & Business Background

Address
4 / F, 10 Xingye Road, Torch Development Zone, Zhongshan, Guangdong, China
Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment, Money Gram
International Commercial Terms(Incoterms)
FOB, EXW, CIF
Average Lead Time
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays
Nearest Port
Zhongshan

Our Production Capability & Technical Expertise

Main Products
Fire Alarm System, Smoke Detector, Fire Alarm Control Panel, Fire Alarm, FM200, Fire Pump, Flame Detector, Fire Hose Reel, Emergency Light System, Beam Smoke Detector

Our Industry Experience & Global Business Record

Export Year
2005-06-01
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe

FAQ

What is the maximum number of zones this panel supports?
The panel supports up to 32 zones and can be expanded from 1 to 32 zones easily.
Does this fire alarm panel meet international safety standards?
Yes, the AW-CFP2166 series is designed based on EN54 part 2&4 standards.
What are the power supply specifications?
It accepts 110VAC or 240VAC mains supply and provides 24VDC and 5VDC power outputs.
Can the battery be protected against low voltage?
Yes, it has a battery low protection function that cuts off the battery automatically when voltage is lower than 21VDC.
What types of outputs does the panel provide?
It offers FIRE and FAULT signal outputs (NC and NO relay), and 2 general sounder outputs.
Is it possible to add GSM functionality for SMS alerts?
Yes, an optional GSM module is available for fire alarm notifications via SMS.
How many detectors can be connected per zone?
A maximum of 20 smoke/heat detectors per zone is supported based on a total detector current of 2mA.
What is the delivery time for this product?
The delivery time is within 15 working days for both peak and off-peak seasons.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now