AC INPUT | 220VAC 50HZ | +10% |
-15% | ||
DC OUTPUT at Power Board | 24VDC (19V-28V) and 5VDC (4.9V-5.1V) | |
Voltage for MCU | 5V for power board MCU, 3.3V for others | |
Current at 24VDC from PSE | <450mA standby current | |
Maximum current from PSE | 1.4A except batteries charge | |
Batteries current | 1.85A maximum, current limited | |
Auxiliary output | 24VDC, 200 mA max, current limited | |
Extinguishant release delay time | Adjustable 0 to 60seconds(5 second steps) | |
Imin, Imax.a and Imax.b according to EN54-2 | Imin=340mA, Imax.a=424mA, Imax.b=1.4A | |
Batteries | 2*12V/ 2.3Ah sealed lead acid gel, self-regulated | |
Battery replace Resistance | 1.6Ω±10% if needed | |
Battery low-voltage protection | 21V | |
The maximum and minimum electrical ratings for each input and output | Detectots / zone lines: 15.2V-28V Sounder lines:19-28V Fire protection/Fire routing lines:19-28V Fault routing lines:18-28V |
|
Detectors wiring allowed each zone | 16 points | |
Max points (detector and MCP) per CIE | 32 points | |
Zone alarm current | 6mA minimum/ 27mA maximum | |
Sounder output | 200mA maximum | |
Fire routing/ Fault routing | 200mA maximum each terminal | |
Communication protocol | 2 wires RS485 bus system | |
EOL resistor for zone, inputs(Except for main power) and outputs | 6.8K 1W | |
Wires for 220V AC IN (recommended) | 16AWG | |
Wires connect power board to interface board (recommended) | 20AWG | |
Wire for main board wiring with interface board (recommended) | 28AWG | |
Fuse on power board | 3A/ 250V Glass tube fuse 5*20(mm) Fast/quick blow | |
Fuses on interface board(general outputs) | 0.2A /250V Glass tube fuse 5*20(mm) Fast/quick blow [*5pcs] | |
Fuse on interface board(Main Power) | 2A/ 250V Ceramic tube fuse 5*20(mm) Slowly blow | |
Fuse on interface board(EM valve) | 1.5A/ 250V Glass tube fuse 5*20(mm) Fast/quick blow | |
Environmental | Class A temperature range: -5 to 40°C (23~104°F) Humidity: 5 to 95% RH, non-condensing |
|
Terminal blocks rating | All terminals rated for 12 to18 AWG (0.75 to 2.5 mm2) |
|
Wires between interface board (Panel)and Detector (recommended) | 2-core shielded cable for 12 to18 AWG (0.75 to 2.5 mm2) |
Product Images
Company Information:
ASENWARE is the fire alarm system and fire suppression system manufacturer and whole fire safety solution provider since 2005.
Driven by a commitment to sound operations, ongoing innovation, and open collaboration, we have established a competitive fire safety products line include addressable fire alarm system, conventional fire alarm system, central monitoring emergency light system, fire telephone and emergency audio system, fire pump, fire hose and gas suppression system.
Our fire safety products ,solutions and services are used in over 100 countries.
With over 200 employees work in United Kingdom-Marketing Center, China-R&D and Supply Chain Center and Bangladesh-Manufacture
Center, ASENWARE is committed to design and manufacture the best fire safety products to reduce the risk of fire, and support theworld to be more safe and more comfortable.
Exhibition:
Certification:
Contact:
Lily Huang
Shenzhen Asenware Test&Control Technology Co.,Ltd
Website:asenware.en.made-in-china.com
Factory Add: 4F,10#, Xingye Rd., Huoju District, Zhongshan City, Guangdong
Marketing Center AddR: 26H, Building D, Shihong Garden, Fanshen Rd, Baoan, Shenzhen