• 24V 2-Wire Cost Performance Photoelectric Smoke Detector
  • 24V 2-Wire Cost Performance Photoelectric Smoke Detector
  • 24V 2-Wire Cost Performance Photoelectric Smoke Detector
  • 24V 2-Wire Cost Performance Photoelectric Smoke Detector
  • 24V 2-Wire Cost Performance Photoelectric Smoke Detector
  • 24V 2-Wire Cost Performance Photoelectric Smoke Detector

24V 2-Wire Cost Performance Photoelectric Smoke Detector

Type: Smoke Alarm
Signal Transmission: Wired Alarm
Working Mode: Active
Application: Indoor
Working Principle: Electro-Optical Type
Height: 2.2" (55 Mm) Installed in Base
Samples:
US$ 1/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
AW-CSD311
Diameter
4.0"(103 Mm)
Weight
5.5 Oz. (155 G)
Standby Current
D100ua 24 VDC
Maximum Alarm Current (LED on: )
D55mA 24 VDC
Operating Voltage Range
9 to 32 VDC Volts Non-Polarized
Operating Humidity Range
10% to 93% Relative Humidity, Non-Condensing
Operating Temperature Range
14°f to 120°f (-10°c to 49°c)
Transport Package
Gift Box + Standard Export Carton
Specification
CE
Trademark
Asenware
Origin
Guangdong, China
HS Code
853111000
Production Capacity
100, 000/Month

Product Description

24V 2-Wire Cost Performance Photoelectric Smoke Detector
24V 2-Wire Cost Performance Photoelectric Smoke Detector


Model: AW-CSD311

Featured by:
1. Photoelectronic detector uses a state of-the-art optical sensing chamber. This detector is designed to provide open area protection and to be used with most conventional fire alarm control panel.

2. Two LEDs on provides 360° Visible alarm alert which flashes every 3~5 seconds indicating that power is on and the detector is working properly.

3. LEDs become normal red in case of alarming.

Operating Voltage Range: 9-32V
15KG/100pcs

Warranty:
We are serious & resopnsible fire alarm complete solution provider with QC warranty within 12 months.
Operating Voltage Range 9 to 28 VDC Volts Non-polarized
Standby Current ≤120μA@24VDC
Maximum Alarm Current (LED on)

≤15mA@24VDC
(1K Ohm current-limiting resistance)

Operating Humidity Range ≤95%RH(40°C±2°C) Relative Humidity, Non-condensing
Operating Temperature Range -10°C to 50°C (14°F to 122°F)
Smoke Alarm Sensitivity 1.06±.26%FT
Fix temperature Alarm 57°C (135°F) A1R
Rate of rise Alarm 7.1°C/5S A1R
Height 48.2 mm installed in Base
Diameter 99.45 mm

24V 2-Wire Cost Performance Photoelectric Smoke Detector
24V 2-Wire Cost Performance Photoelectric Smoke Detector
24V 2-Wire Cost Performance Photoelectric Smoke Detector

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Plant Area
>2000 square meters
Management System Certification
ISO 9001