BMS Fire Protection Fire Alarm Host

Product Details
Customization: Available
Type: Industry Alarm
Signal Transmission: Wired Alarm
Still deciding? Get samples of US$ 60/Piece
Request Sample
Manufacturer/Factory, Trading Company

360° Virtual Tour

Diamond Member Since 2013

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
Fast Delivery
The supplier can deliver the goods within 30 days
Overseas Services
The supplier provides overseas services and supports countries including UK.

Overseas service content includes Debugging, Maintain, Repair, Training, Equipment Installation.
to see all verified strength labels (28)
  • BMS Fire Protection Fire Alarm Host
  • BMS Fire Protection Fire Alarm Host
  • BMS Fire Protection Fire Alarm Host
  • BMS Fire Protection Fire Alarm Host
  • BMS Fire Protection Fire Alarm Host
  • BMS Fire Protection Fire Alarm Host
Find Similar Products

Basic Info.

Model NO.
AW-CFP2166-8
Working Mode
Active
Certification
CE, ISO, RoHS, CCC
Application
Indoor, Fire Projects
Working Principle
Response to The Trigger Device
Transmission Mode
Cable
Alarm Volume (within 1m)
≥110dB
Receive Frequency
Cable
Extendable Zones
1-32 Zones 20
Power Supply
240VAC
Backup Lead-Acid Battery
24VDC
Optional Housing Color
Grey, Red, Black, White
Individual Zone Capacity
20 Detectors Max.
Wiring Structure
2-Wire System
Housing Material
Metal
Mainboard & Zone Board
SMT Workmanship
Alarm Notification
LCD Panel & LED Indicator
Package
Seaworthy
Transport Package
EPE Inside, Carton Outside
Specification
Working on LPCB Certificate
Trademark
Asenware
Origin
Guangdong, China
HS Code
853110000
Production Capacity
10, 000PCS/Year

Product Description

BMS Fire Protection Fire Alarm Host
BMS Fire Protection Fire Alarm Host


Introductions:
1. Based on EN54 part 2 & 4 standard.
2. Modularized design with flexible following extendable capacity.
3. Two-level control mode by a lock
4.27VDC power supply output.
5. FIRE PROTECTION, FIRE ROUTING and FAULT signal output, the output can be configured to dry relay type or wet sources type.
6.2 channel general sounders output.
7. Each zone has 1 circuit detectors input.
8. Each zone can be disable by a button.
9. RESET button to reset the panel.
10. SILENCE button to stop BUZZER and SOUNDERS.
11. EVACUATE button to start a manual fire alarm immediately.
12. TEST button to test all LEDs orderly.
13. Low-battery level protection with automatic power supply switch function
14. Optional GSM module is available for fire alarm by SMS.

Asenware, professional fire alarm solution provider.
ITEM 1Zone panel 2Zone panel 4-8 Zone panel 12-32 Zone panel
Model No. AW-CFP2166-01 AW-CFP2166-02 AW-CFP2166-04-8 AW-CFP2166-12-32
Power specification
 
Mains supply voltage 110VAC or 240VAC
Internal power supply 27.2VDC
Total output current limited 500mA @ 240VAC 500mA @ 240VAC 3A @ 240VAC 3A @ 240VAC
Main supply monitor for fault Yes
Battery protection for low voltage Yes
Batteries (default configuration) 12V2AH*2
Detector circuit specification
 
Number of circuit 1 2 4-16 4-32
Line fault monitor for open circuit Yes
Line fault monitor for short circuit Yes
Line fault monitor for detector removal Yes, if End of Line Monitor Unit fitted in place of End of Line Resistor
End of Line device 6.8k Ω,5% tolerance, 0.25W (colour code-blue,grey,red,gold)
Detector continuity diodes Silicon 1N4001 or Schottky type (required if End of Line Monitor Unit fitted to give Detector Removal Fault)
Call point resistor value 470 to 680 Ω, 0.225 or 0.5 watt
Maximum number of smoke/heat detectors per zone 20 (based on a total detector current of 2mA, each detector consuming 100μA).Note: if End of Line Monitor Unit is fitted, for correct operation maxmum voltage drop must not exceed 12 volts.
Maximum number of manual call points per zone No limit
Sounder circuit specification
 
Number of general circuits 2
End of line resistor value 6.8k Ω,5% tolerance, 0.25W (colour code-blue,grey,red,gold)
Line fault monitor for open circuit Yes
Line fault monitor for short circuit Yes
Outputs fused AT 400mA
Maximum number of bells @ 20mA of each sounder output 20
Fuses
 
Battery fuse 1.5A F 20mm
Sounder outputs 500mA F 20mm
Fire and fault output
 
Output type NC and NO relay
Maximum current 100mA
Connection block
 
Largest acceptable conductor size 2.5mm2
Smallest acceptable conductor size 0.75mm2
Size and weight
 

 
Dimensions(mm) 272*200*70mm 320*231*90mm 395X502X124 362X565X124
Weight (without batteries) 4kg 5kg 7kg 8kg
Weight (with batteries) 5.8kg 6.8kg 9.6kg 12.5kg
BMS Fire Protection Fire Alarm Host
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier