• Wireless Conventional Fire Alarm Control Panel
  • Wireless Conventional Fire Alarm Control Panel
  • Wireless Conventional Fire Alarm Control Panel
  • Wireless Conventional Fire Alarm Control Panel
  • Wireless Conventional Fire Alarm Control Panel

Wireless Conventional Fire Alarm Control Panel

Type: Fire Alarm
Anti-theft Alarm System Approach: Active
Anti-Theft Alarm System Type: Smoke Alarms
Anti-Theft Alarm System-Wide: Wire Alarm Detectors
Anti-Theft Alarm System Distance: Power Detector
Types of Smoke Detectors: Photoelectric Smoke Style
Samples:
US$ 60/Piece 1 Piece(Min.Order)
| Request Sample
Customization:

Contact Supplier

Miss Christine Chen
Sales Director
Diamond Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
AW-CFP2166
Infrared Sensor Probe Type
Inclination Sensor
Infrared Sensor Installation
Ceiling
Combustible Gas Detector Model
NA-300
Item
Detection Control Panel
Zones
1-32
Power Supply
110VAC/240VAC
Battery
12V2ah*2
Fire Relay Output
Nc and No
Fault Relay Output
Nc and No
Sounder Output
2 Circuits
Fob Port
Shenzhen
Delivery Time
15 Days
Payment
T/T, Western Union
Transport Package
EPE Inside, Carton Outside
Specification
CE
Trademark
Asenware
Origin
Guangdong, China
Production Capacity
10000PCS/Year

Product Description

wireless conventional fire detection control panel

Introduction:


The AW-CFP2166 series wireless conventional fire alarm panel is designed based on EN54 part 2&4 standard. And it is the central part of conventional fire alarm system, designed for applications requiring smoke detector, bell, manual pull stations, and sprinkler supervision. Each zone can be disabled by a button. The basic unit offers 1 to 8 zones of initiation, up to 16 zones for larger applications.


Wireless Conventional Fire Alarm Control Panel


1 AW-CFP2166 series conventional fire alarm panel is designed based on EN54 part 2&4 standard.
2 It is modularized design, the panel can expend from 1 zone to 32 zones easily.
3 It has 2 level control mode by a lock
4 It has 24VDC and 5VDC power supply output.
5 It has FIRE and FAULT signal output.
6 It has 2 general sounders output.
7 Each zone has 1 circuit detectors input.
8 Each zone can be disable by a button.
9 It has RESET button to reset the panel.
10 It has SILENCE button to stop BUZZER and SOUNDERS.
11 It has EVACUATE button to start a manual fire alarm immediately.
12 It has battery low protection function, when battery voltage lower than 21VDC, battery will be cut off automatically until the mains power is on.
13 It has an optional GSM module for fire alarm by SMS.
14 It is economic, user-friendly and easy maintenance.
Wireless Conventional Fire Alarm Control Panel

Parameters:
ITEM 1Zone panel 2Zone panel 4-8 Zone panel 12-32 Zone panel
Model No. AW-CFP2166-01 AW-CFP2166-02 AW-CFP2166-04-8 AW-CFP2166-12-32
Power specification
 
Mains supply voltage 110VAC or 240VAC
Internal power supply 27.2VDC
Total output current limited 500mA @ 240VAC 500mA @ 240VAC 3A @ 240VAC 3A @ 240VAC
Main supply monitor for fault Yes
Battery protection for low voltage Yes
Batteries (default configuration) 12V2AH*2
Detector circuit specification
 
Number of circuit 1 2 4-16 4-32
Line fault monitor for open circuit Yes
Line fault monitor for short circuit Yes
Line fault monitor for detector removal Yes, if End of Line Monitor Unit fitted in place of End of Line Resistor
End of Line device 6.8k Ω,5% tolerance, 0.25W (colour code-blue,grey,red,gold)
Detector continuity diodes Silicon 1N4001 or Schottky type (required if End of Line Monitor Unit fitted to give Detector Removal Fault)
Call point resistor value 470 to 680 Ω, 0.225 or 0.5 watt
Maximum number of smoke/heat detectors per zone 20 (based on a total detector current of 2mA, each detector consuming 100μA).Note: if End of Line Monitor Unit is fitted, for correct operation maxmum voltage drop must not exceed 12 volts.
Maximum number of manual call points per zone No limit
Sounder circuit specification
 
Number of general circuits 2
End of line resistor value 6.8k Ω,5% tolerance, 0.25W (colour code-blue,grey,red,gold)
Line fault monitor for open circuit Yes
Line fault monitor for short circuit Yes
Outputs fused AT 400mA
Maximum number of bells @ 20mA of each sounder output 20
Fuses
 
Battery fuse 1.5A F 20mm
Sounder outputs 500mA F 20mm
Fire and fault output
 
Output type NC and NO relay
Maximum current 100mA
Connection block
 
Largest acceptable conductor size 2.5mm2
Smallest acceptable conductor size 0.75mm2
Size and weight
 

 
Dimensions(mm) 272*200*70mm 320*231*90mm 395X502X124 362X565X124
Weight (without batteries) 4kg 5kg 7kg 8kg
Weight (with batteries) 5.8kg 6.8kg 9.6kg 12.5kg

Company
Wireless Conventional Fire Alarm Control Panel



Wireless Conventional Fire Alarm Control Panel

Certificate
Wireless Conventional Fire Alarm Control Panel

 FAQ

Q1:Can I have a sample order?
A:Yes,we welcome sample order to test and check quality.

Q2:What is the lead time?
A:Sample needs 1-3 days, mass product according to your quantity.

Q3:How do you ship the goods and how long does it take arrive?
A:We usually ship by DHL,UPS,FedEX or by Air. 3-5 days after payment received.

Q4:Do you guarantee for the products?
A:Yes,we offer one year guarantee for the products.

Q5:Do you offer OEM service?
A:Yes,we can design the products according to your request.

Send your message to this supplier

*From:
*To:
avatar Miss Christine Chen
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now