FM 200 Fire Suppression System Cabinet Type Gas Fire Suppression System

Shenzhen Asenware Test and Control Technology Co., Ltd.
  • Audited Supplier
  • 14 yrs

Contact Supplier

Product Highlights

  • NFPA 2001 Compliant Design: Engineered system designed and installed in accordance with NFPA Standard 2001.
  • Rapid Discharge Capability: Discharges 95% of required agent mass within 10 seconds for immediate suppression.
  • Multi-Class Fire Protection: Effectively suppresses Class A, B, and C hazards including flammable liquids and electrical fires.
  • Flexible Cylinder Capacities: Available in 70L, 90L, 100L, 120L, 150L, and 180L volumes to suit various needs.
  • Advanced Detection Integration: Compatible with ASENWARE detection systems featuring cross, counting, and priority-zone configurations.
  • OEM Customization Services: We can design products according to your specific requests and requirements.
  • Sample Order Availability: Sample orders are welcome to test and verify product quality before bulk purchase.
  • Global Shipping Options: Shipped via DHL, UPS, FedEx, or Air with arrival within 3-5 days after payment.

Product Images of FM 200 Fire Suppression System Cabinet Type Gas Fire Suppression System

FM 200 Fire Suppression System Cabinet Type Gas Fire Suppression System pictures & photos
FM 200 Fire Suppression System Cabinet Type Gas Fire Suppression System
FM 200 Fire Suppression System Cabinet Type Gas Fire Suppression System pictures & photos
FM 200 Fire Suppression System Cabinet Type Gas Fire Suppression System
  • FM 200 Fire Suppression System Cabinet Type Gas Fire Suppression System
    FM 200 Fire Suppression System Cabinet Type Gas Fire Suppression System
  • FM 200 Fire Suppression System Cabinet Type Gas Fire Suppression System
    FM 200 Fire Suppression System Cabinet Type Gas Fire Suppression System

Find Similar Products

Product Description

FM200 Fire Detection and Gas Suppression Systems Cabinet Type
FM 200 Fire Suppression System Cabinet Type Gas Fire Suppression System


FM-200 Fire Suppression System

The FM-200 Fire Suppression System is an engineered system  utilizing a fixed nozzle agent distribution network. The system is designed and installed in accordance with the National Fire Protection Association (NFPA) Standard 2001, "Clean Agent Fire Extinguishing Systems." When properly designed, the FM-200 system will suppress surface burning fire in Class A, B, and C hazards.

The clean agent fire extinguishing system shall perform as outlined in the following sub-sections.
A. Achieve a 6.25% (v/v) extinguishing concentration for Class A (Surface Type Fires) hazards.

B. Achieve a 8.70% (v/v) or greater, as required, extinguishing concentration for Class B (Flammable Liquids) hazards.

C. Achieve a 7.00% (v/v) extinguishing concentration for Class C (Energized Electrical Equipment) hazards.

D. Within 10 seconds, the clean agent fire extinguishing system shall discharge 95% of the required suppression agent mass.

E. The clean agent fire extinguishing system shall consist of one or more Asenware Fire Systems agent cylinders and related equipment. The cylinders may be either connected to a discharge pipe arrangement separately or connected to a common manifold and discharge pipe arrangement. The agent cylinders shall be filled with FM-200, and super pressurized with dry nitrogen to a working pressure of 360 PSIG at 70°F (24.8 bar gauge at 21°C).

FM200 technical parameters

Tempreture ºC
0-50
20ºC Storage pressure(Mpa)
 
2.5 4.2 5.6
20ºCmaximum working pressure
(Mpa)

 
4.2 6.7 8
Cylinder (L) 100 70/90/100/120/150/180 90
AGENT kg/m3 ≤1120 ≤1120 ≤1080
Nozzal pressure ≥0.6 ≥0.7 ≥0.8
Discharge time Computer room ≤8  others≤10
concentration 8-10%

FM 200 system operation
A. The clean agent fire extinguishing system shall consist of FM-200, agent cylinder(s),  actuation hardware and  discharge nozzle(s) attached to a pipe network

B Detection System - The ASENWARE Detection System is used where an automatic electronic detection system is required to actuate the FM-200 suppression system. This detection system is
used to actuate a single, fixed, fire suppression or alarm system based on inputs received from fire detection devices. The detection circuits can be configured using cross, counting, independent or priority-zone (counting) concepts. The detection system has been tested to the applicable FCC Rules and Regulations for Class A Computing devices.FM200 fire detection and suppression systems





Our company

ASENWARE is the fire alarm system and fire suppression system manufacturer and whole fire safety solution provider since 2005.

Driven by a commitment to sound operations, ongoing innovation, and open collaboration, we have established a competitive fire safety products line include addressable fire alarm system, conventional fire alarm system, central monitoring emergency light system, fire telephone and emergency audio system, fire pump, fire hose and gas suppression system.

Our fire safety products ,solutions and services are used in over 100 countries.
FM 200 Fire Suppression System Cabinet Type Gas Fire Suppression System
FM 200 Fire Suppression System Cabinet Type Gas Fire Suppression System




FAQ 

Q1: Are you manufacturer?
A: (yes)

Q2: What is the lead time?
A: usually
Fire control: one week working day
bulk quality: three weeks working days
Emergency lights: two weeks working days
bulk quality: four weeks
FM200:  two weeks working day
Fire pump: 25 days

Q3: How do you ship the goods and how long does it take arrive?
A: We usually ship by DHL, UPS, FedEx or by Air. 3-5 days after payment received.

Q4: Can I have a sample order?
A:Yes,we welcome sample order to test and check quality.

Q5: Do you offer OEM service?
A: Yes, we can design the things according to your request.


 

About the Supplier

This supplier has been audited by CTI. Verify the report on the official CTI website with ID "QIP-ASR242972". Items marked "verified" are certified.

Shenzhen Asenware Test and Control Technology Co., Ltd.
Shenzhen Asenware Test and Control Technology Co., Ltd.
Shenzhen Asenware Test and Control Technology Co., Ltd.
Shenzhen Asenware Test and Control Technology Co., Ltd.
Shenzhen Asenware Test and Control Technology Co., Ltd.
Shenzhen Asenware Test and Control Technology Co., Ltd.
Shenzhen Asenware Test and Control Technology Co., Ltd.
Shenzhen Asenware Test and Control Technology Co., Ltd.

About Our Factory & Business Background

Address
4 / F, 10 Xingye Road, Torch Development Zone, Zhongshan, Guangdong, China
Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment, Money Gram
International Commercial Terms(Incoterms)
FOB, EXW, CIF
Average Lead Time
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays
Nearest Port
Zhongshan

Our Production Capability & Technical Expertise

Main Products
Fire Alarm System, Smoke Detector, Fire Alarm Control Panel, Fire Alarm, FM200, Fire Pump, Flame Detector, Fire Hose Reel, Emergency Light System, Beam Smoke Detector

Our Industry Experience & Global Business Record

Export Year
2005-06-01
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe

FAQ

Are you a manufacturer?
Yes
What is the lead time?
Fire control: one week working day bulk quality: three weeks working days Emergency lights: two weeks working days bulk quality: four weeks FM200: two weeks working day Fire pump: 25 days
How do you ship the goods and how long does it take arrive?
We usually ship by DHL, UPS, FedEx or by Air. 3-5 days after payment received.
Can I have a sample order?
Yes,we welcome sample order to test and check quality.
Do you offer OEM service?
Yes, we can design the things according to your request.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now