Conventional Fire Alarm System Smoke Detector

Product Details
Customization: Available
Type: Smoke Detectors
Anti-theft Alarm System Approach: Conventional
Manufacturer/Factory, Trading Company

360° Virtual Tour

Diamond Member Since 2013

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
Fast Delivery
The supplier can deliver the goods within 30 days
Overseas Services
The supplier provides overseas services and supports countries including UK.

Overseas service content includes Debugging, Maintain, Repair, Training, Equipment Installation.
to see all verified strength labels (28)
  • Conventional Fire Alarm System Smoke Detector
  • Conventional Fire Alarm System Smoke Detector
  • Conventional Fire Alarm System Smoke Detector
  • Conventional Fire Alarm System Smoke Detector
  • Conventional Fire Alarm System Smoke Detector
  • Conventional Fire Alarm System Smoke Detector
Find Similar Products

Basic Info.

Model NO.
AW-CSD381
Anti-Theft Alarm System Type
Smoke Alarms
Anti-Theft Alarm System-Wide
Wire Alarm Detectors
Types of Smoke Detectors
Photoelectric Smoke Style
Infrared Sensor Installation
Ceiling
Operating Voltage Range
18V-28VDC
Work Current
Less Than 2.5mA
Smoke Sensitivity
0.2-0.3 dB/M
Standard Number Ref
En 57-7:2000
Standby Current
120ua@24VDC
Maximum Alarm Current
15mA@24VDC
Ec Certificate
0832-CPR-F2071
Transport Package
Standard Export Cartons
Trademark
ASENWARE
Origin
China
HS Code
8531901000
Production Capacity
100000/Month

Product Description

Product Description

LPCB EN54 approval conventional smoke detector



Conventional Fire Alarm System Smoke Detector


Introduction:

AW-CSD381 is conventional photo-electronic smoke detector uses a state of-the-art optical sensing chamber. This detector is designed to provide open area protection and to be used with most conventional fire alarm panel.

The conventional rate of rise of rise heat detector uses thermal component to detect the temperature changing in the environment. It can enable fire alam when the temperature difference achieved the setting rate of rise temperature value reach the setting fixed ualue. It has a stable and reliable working performance.

Two LEDs on each detector provide local 360° visible alarm indication. They flash every six seconds indicating that power is applied and the detector is working properly. The LEDs latch on in alarm. LEDs will be off when a trouble condition exists indicating that the detector sensitivity is outside the listed limit. The alarm can be reset only by a momentary power interruption.

The detector that initiated the alarm condition will have its red LED and relays latched until reset by panel.

 
Operating Voltage Range 9 to 28 VDC Volts Non-polarized
Standby Current ≤120uA@24VDC
Maximum Alarm Current (LED on)

≤15mA@24VDC
(1K Ohm current-limiting resistance)

Operating Humidity Range ≤95%RH(40ºC±2ºC)RelativeHumidity,Non-condensing
Operating Temperature Range -10ºC to 50ºC(14ºF to 122ºF)
Smoke Alarm Sensitivity 0.1-0.15dB/m
Height 48.2mm installed in Base
Diameter 99.45mm
Standard Number ref EN 54-7:2000
EC certificate 0832-CPR-F2071

Detailed Images
Conventional Fire Alarm System Smoke Detector
Our company
Asenware, manufacturer of fire alarm and fire suppression system since 2005. Our headquarter is in London, UK, with factory Shenzhen, China
We keep our best service for our customers, and have a rich experienced engineer team to design and install for overseas projects.
Conventional Fire Alarm System Smoke Detector


Product range
1. Addressable fire alarm system(FP100 series,2189,2100 series)
2. Conventional fire alarm system(2166 series)
3. FM200 gas fire suppression system
4. Emergency light system
5. Fire pump system
6. Fire hose and fire hose reel cabinet

Packaging & Shipping
Packaging Details:
1) PEE bag per unit 
2) Outside Cartons
3)Strict & Standard Export Packing Procedures Adopted Exterior Corrugated Hardboard Carton Interior Blister Buffer Staff, Asenware fire pump control equipment.
Conventional Fire Alarm System Smoke Detector


Exhibition:
Conventional Fire Alarm System Smoke Detector
Certificate:
Conventional Fire Alarm System Smoke Detector

Our Services
1.OEM / ODM services.
2.Professional technical team.
3.Offer Free technical support whenever you need
4.Two year warranty and technical maintenance

FAQ 
Q1: Are you manufacturer?
A: (yes)
Q2: What is the lead time?
A: usually
Fire control: one week working day
bulk quality: three weeks working days
Emergency lights: two weeks working days
bulk quality: four weeks
FM200:  two weeks working day
Fire pump: 25 days
Q3: How do you ship the goods and how long does it take arrive?
A: We usually ship by DHL, UPS, FedEx or by Air. 3-5 days after payment received.
Q4: Can I have a sample order?
A:Yes,we welcome sample order to test and check quality.
Q5: Do you offer OEM service?
A: Yes, we can design the things according to your request.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier