Product Highlights
- NFPA 2001 Compliant Design: Engineered system installed per NFPA Standard 2001 for clean agent fire suppression.
- Multi-Class Fire Suppression: Effectively suppresses Class A, B, and C hazards including flammable liquids and electrical equipment.
- Rapid Discharge Performance: Discharges 95% of required agent mass within 10 seconds for immediate fire control.
- Customizable Cylinder Capacity: Available in various capacities including 70L, 90L, 100L, 120L, 150L, and 180L.
- CE Certification: Product holds CE certification ensuring compliance with European safety standards.
- Flexible Working Pressure: Supports working pressures of 2.5, 4.2, or 5.6 MPa to suit different system requirements.
- Wide Temperature Range: Operates effectively in temperatures ranging from 0 to 50 degrees Celsius.
- Integrated Detection System: Compatible with automatic electronic detection systems for instant actuation and alarm.
Product Attributes
- Customization
- Available
- Agent
- Alkyl Halide
- Type
- Fixed
- Model NO.
- AW-FM200
- Object
- Class A Fires
- Size
- 40L/70L/90L/120L/150L
- Certification
- CE
- Effective Range
- 8m
- Capacity
- 70L/90L/100L/120L/150L/180L
- Name
- FM-200 Fire Suppression System
- Pressure
- 2.5/4.2/5.6MPa
- Fire
- Class a/B/C
- Clynder Color
- Red
- Siries
- Standalone Network
- Working Temperature
- 0 Degree to 50 Degree
- Packaging
- Wooden
- Work
- Fire Detection System
- Discharging Time
- Less 10s
- Transport Package
- Wooden Packing
- Specification
- CE ISO
- Trademark
- Asenware
- Origin
- Shenzhen China
- HS Code
- 8531100000
- Production Capacity
- 1000000/Year
Product Images of FM-200 Fire Suppression System Fire Extinguisher
Find Similar Products
Product Description
FM-200 Fire Suppression System fire extinguisher

The FM-200 Fire Suppression System is an engineered system utilizing a fixed nozzle agent distribution network. The system is designed and installed in accordance with the National Fire Protection Association (NFPA) Standard 2001, "Clean Agent Fire Extinguishing Systems." When properly designed, the FM-200 system will suppress surface burning fire in Class A, B, and C hazards.
The clean agent fire extinguishing system shall perform as outlined in the following sub-sections.
A. Achieve a 6.25% (v/v) extinguishing concentration for Class A (Surface Type Fires) hazards.
B. Achieve a 8.70% (v/v) or greater, as required, extinguishing concentration for Class B (Flammable Liquids) hazards.
C. Achieve a 7.00% (v/v) extinguishing concentration for Class C (Energized Electrical Equipment) hazards.
D. Within 10 seconds, the clean agent fire extinguishing system shall discharge 95% of the required suppression agent mass.
E. The clean agent fire extinguishing system shall consist of one or more Asenware Fire Systems agent cylinders and related equipment. The cylinders may be either connected to a discharge pipe arrangement separately or connected to a common manifold and discharge pipe arrangement. The agent cylinders shall be filled with FM-200, and super pressurized with dry nitrogen to a working pressure of 360 PSIG at 70°F (24.8 bar gauge at 21°C).
FM200 technical parameters
FM 200 system operation
A. The clean agent fire extinguishing system shall consist of FM-200, agent cylinder(s), actuation hardware and discharge nozzle(s) attached to a pipe network
B Detection System - The ASENWARE Detection System is used where an automatic electronic detection system is required to actuate the FM-200 suppression system. This detection system is
used to actuate a single, fixed, fire suppression or alarm system based on inputs received from fire detection devices. The detection circuits can be configured using cross, counting, independent or priority-zone (counting) concepts. The detection system has been tested to the applicable FCC Rules and Regulations for Class A Computing devices.

The FM-200 Fire Suppression System is an engineered system utilizing a fixed nozzle agent distribution network. The system is designed and installed in accordance with the National Fire Protection Association (NFPA) Standard 2001, "Clean Agent Fire Extinguishing Systems." When properly designed, the FM-200 system will suppress surface burning fire in Class A, B, and C hazards.
The clean agent fire extinguishing system shall perform as outlined in the following sub-sections.
A. Achieve a 6.25% (v/v) extinguishing concentration for Class A (Surface Type Fires) hazards.
B. Achieve a 8.70% (v/v) or greater, as required, extinguishing concentration for Class B (Flammable Liquids) hazards.
C. Achieve a 7.00% (v/v) extinguishing concentration for Class C (Energized Electrical Equipment) hazards.
D. Within 10 seconds, the clean agent fire extinguishing system shall discharge 95% of the required suppression agent mass.
E. The clean agent fire extinguishing system shall consist of one or more Asenware Fire Systems agent cylinders and related equipment. The cylinders may be either connected to a discharge pipe arrangement separately or connected to a common manifold and discharge pipe arrangement. The agent cylinders shall be filled with FM-200, and super pressurized with dry nitrogen to a working pressure of 360 PSIG at 70°F (24.8 bar gauge at 21°C).
FM200 technical parameters
Tempreture ºC |
0-50 | ||
| 20ºC Storage pressure(Mpa) |
2.5 | 4.2 | 5.6 |
| 20ºCmaximum working pressure (Mpa) |
4.2 | 6.7 | 8 |
| Cylinder (L) | 100 | 70/90/100/120/150/180 | 90 |
| AGENT kg/m3 | ≤1120 | ≤1120 | ≤1080 |
| Nozzal pressure | ≥0.6 | ≥0.7 | ≥0.8 |
| Discharge time | Computer room ≤8 others≤10 | ||
| concentration | 8-10% | ||
FM 200 system operation
A. The clean agent fire extinguishing system shall consist of FM-200, agent cylinder(s), actuation hardware and discharge nozzle(s) attached to a pipe network
B Detection System - The ASENWARE Detection System is used where an automatic electronic detection system is required to actuate the FM-200 suppression system. This detection system is
used to actuate a single, fixed, fire suppression or alarm system based on inputs received from fire detection devices. The detection circuits can be configured using cross, counting, independent or priority-zone (counting) concepts. The detection system has been tested to the applicable FCC Rules and Regulations for Class A Computing devices.
About the Supplier
This supplier has been audited by CTI. Verify the report on the official CTI website with ID "QIP-ASR242972". Items marked "" are certified.
Company Profile
Company Information
ASENWARE is the fire alarm system and fire suppression system manufacturer and whole fire safety solution provilder since 2005. Driven by a commitment to sound operations, ongoing innovation, and open collaboration, we have established a competitive fire safety products line including addressable fire alarm system, conventional fire alarm system, central monitoring emergency light system, fire telephone and voice evacuation system, fire pump, fire hose and gas suppression system.
About Our Factory & Business Background
- Address
- 4 / F, 10 Xingye Road, Torch Development Zone, Zhongshan, Guangdong, China
- Terms of Payment
- LC, T/T, D/P, PayPal, Western Union, Small-amount payment, Money Gram
- International Commercial Terms(Incoterms)
- FOB, EXW, CIF
- Average Lead Time
-
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays - Nearest Port
- Zhongshan
Our Production Capability & Technical Expertise
Our Industry Experience & Global Business Record
- Export Year
- 2005-06-01
- Main Markets
- North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe
FAQ
- What types of fires does the FM-200 system suppress?
- The system is designed to suppress Class A (surface burning), Class B (flammable liquids), and Class C (energized electrical equipment) fires.
- What is the discharge time for the FM-200 system?
- The system discharges 95% of the required suppression agent mass within 10 seconds. For computer rooms, discharge time is less than 8 seconds.
- What are the available cylinder capacities?
- Customizable capacities include 70L, 90L, 100L, 120L, 150L, and 180L. Standard options also include 40L and 120L.
- What is the operating temperature range?
- The system works within a temperature range of 0 to 50 degrees Celsius.
- What certifications does the product have?
- The product holds CE certification and is designed in accordance with NFPA Standard 2001.
- What are the terms of payment?
- We accept LC, T/T, D/P, PayPal, Western Union, Small-amount payment, and Money Gram.
- What is the lead time for orders?
- The average lead time is within 15 workdays for both peak and off-season periods.
- How is the detection system configured?
- The detection circuits can be configured using cross, counting, independent, or priority-zone (counting) concepts.
Send your message to this supplier
People who viewed this also viewed
-
US$428.00-858.00 / Piece
-
US$265.00-886.00 / Piece
-
US$70.00-250.00 / Piece
-
US$70.00-250.00 / Piece
-
US$500.00-1,500.00 / Piece
-
US$500.00-1,500.00 / Piece
-
US$209.00-230.00 / Liter
-
US$85.00-99.00 / Liter
-
US$625.00 / Piece
Find Similar Products By Category
- Supplier Homepage
- Products
- Fire Alarm System etc
- Gas Suppression System Cabinet Type
- FM-200 Fire Suppression System Fire Extinguisher
Related Categories
Hot Searches
- Fire Fighting System
- Fire Fighting Product
- Fire Hose Factories
- Water Fire Extinguisher
- Fire Fighting Items Factories
- New Fire Fighting Equipment
- Fire Fighting Security
- Portable Fire Fighting Equipment
- Gas Fire Fighting
- Gas Fire Extinguisher Bulkbuy