Product Highlights

  • NFPA 2001 Compliant Design: Engineered system installed per NFPA Standard 2001 for clean agent fire suppression.
  • Multi-Class Fire Suppression: Effectively suppresses Class A, B, and C hazards including flammable liquids and electrical equipment.
  • Rapid Discharge Performance: Discharges 95% of required agent mass within 10 seconds for immediate fire control.
  • Customizable Cylinder Capacity: Available in various capacities including 70L, 90L, 100L, 120L, 150L, and 180L.
  • CE Certification: Product holds CE certification ensuring compliance with European safety standards.
  • Flexible Working Pressure: Supports working pressures of 2.5, 4.2, or 5.6 MPa to suit different system requirements.
  • Wide Temperature Range: Operates effectively in temperatures ranging from 0 to 50 degrees Celsius.
  • Integrated Detection System: Compatible with automatic electronic detection systems for instant actuation and alarm.

Product Images of FM-200 Fire Suppression System Fire Extinguisher

FM-200 Fire Suppression System Fire Extinguisher
FM-200 Fire Suppression System Fire Extinguisher pictures & photos
FM-200 Fire Suppression System Fire Extinguisher
FM-200 Fire Suppression System Fire Extinguisher pictures & photos
FM-200 Fire Suppression System Fire Extinguisher
FM-200 Fire Suppression System Fire Extinguisher pictures & photos
FM-200 Fire Suppression System Fire Extinguisher
FM-200 Fire Suppression System Fire Extinguisher pictures & photos
FM-200 Fire Suppression System Fire Extinguisher
  • FM-200 Fire Suppression System Fire Extinguisher
  • FM-200 Fire Suppression System Fire Extinguisher
    FM-200 Fire Suppression System Fire Extinguisher
  • FM-200 Fire Suppression System Fire Extinguisher
    FM-200 Fire Suppression System Fire Extinguisher
  • FM-200 Fire Suppression System Fire Extinguisher
    FM-200 Fire Suppression System Fire Extinguisher
  • FM-200 Fire Suppression System Fire Extinguisher
    FM-200 Fire Suppression System Fire Extinguisher

Find Similar Products

Product Description

FM-200 Fire Suppression System fire extinguisher
FM-200 Fire Suppression System Fire Extinguisher


The FM-200 Fire Suppression System is an engineered system  utilizing a fixed nozzle agent distribution network. The system is designed and installed in accordance with the National Fire Protection Association (NFPA) Standard 2001, "Clean Agent Fire Extinguishing Systems." When properly designed, the FM-200 system will suppress surface burning fire in Class A, B, and C hazards.

The clean agent fire extinguishing system shall perform as outlined in the following sub-sections.
A. Achieve a 6.25% (v/v) extinguishing concentration for Class A (Surface Type Fires) hazards.

B. Achieve a 8.70% (v/v) or greater, as required, extinguishing concentration for Class B (Flammable Liquids) hazards.

C. Achieve a 7.00% (v/v) extinguishing concentration for Class C (Energized Electrical Equipment) hazards.

D. Within 10 seconds, the clean agent fire extinguishing system shall discharge 95% of the required suppression agent mass.

E. The clean agent fire extinguishing system shall consist of one or more Asenware Fire Systems agent cylinders and related equipment. The cylinders may be either connected to a discharge pipe arrangement separately or connected to a common manifold and discharge pipe arrangement. The agent cylinders shall be filled with FM-200, and super pressurized with dry nitrogen to a working pressure of 360 PSIG at 70°F (24.8 bar gauge at 21°C).

FM200 technical parameters

Tempreture ºC
0-50
20ºC Storage pressure(Mpa)
 
2.5 4.2 5.6
20ºCmaximum working pressure
(Mpa)

 
4.2 6.7 8
Cylinder (L) 100 70/90/100/120/150/180 90
AGENT kg/m3 ≤1120 ≤1120 ≤1080
Nozzal pressure ≥0.6 ≥0.7 ≥0.8
Discharge time Computer room ≤8  others≤10
concentration 8-10%

FM 200 system operation
A. The clean agent fire extinguishing system shall consist of FM-200, agent cylinder(s),  actuation hardware and  discharge nozzle(s) attached to a pipe network

B Detection System - The ASENWARE Detection System is used where an automatic electronic detection system is required to actuate the FM-200 suppression system. This detection system is
used to actuate a single, fixed, fire suppression or alarm system based on inputs received from fire detection devices. The detection circuits can be configured using cross, counting, independent or priority-zone (counting) concepts. The detection system has been tested to the applicable FCC Rules and Regulations for Class A Computing devices.

About the Supplier

This supplier has been audited by CTI. Verify the report on the official CTI website with ID "QIP-ASR242972". Items marked "verified" are certified.

Shenzhen Asenware Test and Control Technology Co., Ltd.
Shenzhen Asenware Test and Control Technology Co., Ltd.
Shenzhen Asenware Test and Control Technology Co., Ltd.
Shenzhen Asenware Test and Control Technology Co., Ltd.
Shenzhen Asenware Test and Control Technology Co., Ltd.
Shenzhen Asenware Test and Control Technology Co., Ltd.
Shenzhen Asenware Test and Control Technology Co., Ltd.
Shenzhen Asenware Test and Control Technology Co., Ltd.

About Our Factory & Business Background

Address
4 / F, 10 Xingye Road, Torch Development Zone, Zhongshan, Guangdong, China
Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment, Money Gram
International Commercial Terms(Incoterms)
FOB, EXW, CIF
Average Lead Time
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays
Nearest Port
Zhongshan

Our Production Capability & Technical Expertise

Main Products
Fire Alarm System, Smoke Detector, Fire Alarm Control Panel, Fire Alarm, FM200, Fire Pump, Flame Detector, Fire Hose Reel, Emergency Light System, Beam Smoke Detector

Our Industry Experience & Global Business Record

Export Year
2005-06-01
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe

FAQ

What types of fires does the FM-200 system suppress?
The system is designed to suppress Class A (surface burning), Class B (flammable liquids), and Class C (energized electrical equipment) fires.
What is the discharge time for the FM-200 system?
The system discharges 95% of the required suppression agent mass within 10 seconds. For computer rooms, discharge time is less than 8 seconds.
What are the available cylinder capacities?
Customizable capacities include 70L, 90L, 100L, 120L, 150L, and 180L. Standard options also include 40L and 120L.
What is the operating temperature range?
The system works within a temperature range of 0 to 50 degrees Celsius.
What certifications does the product have?
The product holds CE certification and is designed in accordance with NFPA Standard 2001.
What are the terms of payment?
We accept LC, T/T, D/P, PayPal, Western Union, Small-amount payment, and Money Gram.
What is the lead time for orders?
The average lead time is within 15 workdays for both peak and off-season periods.
How is the detection system configured?
The detection circuits can be configured using cross, counting, independent, or priority-zone (counting) concepts.