Guangdong, China
Business Type:
Manufacturer/Factory, Trading Company
Plant Area:
>2000 square meters
Management System Certification:
ISO 9001
Terms of Payment:
LC, T/T, D/P, PayPal, Western Union, Small-amount payment, Money Gram
OEM/ODM Availability:
OEM/ODM Service
Sample Available
Overseas Agent / Branch

Fire Alarms, Fire Alarm Control Panel, Fire Alarm Panel manufacturer / supplier in China, offering Automatic Indoor Security Fire Alarm Detection Panel, Fire Security Control Panel Host Conventional Alarm, Wired Addressable Control Panel Fire Alarm System and so on.

Gold Member Since 2013
Audited Supplier

Automatic Indoor Security Fire Alarm Detection Panel

Get Latest Price
Min. Order / Reference FOB Price
1 Piece US $95/ Piece
Port: Zhongshan, China
Production Capacity: 10000PCS/Year
Payment Terms: L/C, T/T, Western Union, Paypal
Type: Industry Alarm
Signal Transmission: Wired Alarm
Working Mode: Active
Certification: CE, ISO, RoHS, CCC
Application: Indoor
Sensor Type: Electric Alarm

You Might Also Like


Basic Info

Model NO.: AW-CFP2166-8
Working Principle: Response to The Trigger Device
Alarm Volume (within 1m): ≥90dB
Receive Frequency: Cable
Usage: Auto, Fire, Smoke, Factory/Hotel/School/Office Fire Alarm Control
Optional Extendable Zone: 1-32 Zone/20 Detectors/Zone Max.
Power Supply: 240VAC
Backup Lead-Acid Battery: 24VDC
Optional Housing Color: Nc and No
Fault Relay Output: Nc and No
Sounder Output: 2 Circuits
Trademark: Asenware
Transport Package: EPE Inside, Carton Outside
Specification: Working on LPCB Certificate
Origin: Guangdong, China
HS Code: 853110000

Product Description

Automatic Indoor Security Fire Alarm Detection Panel

Automatic Indoor Security Fire Alarm Detection Panel
Automatic Indoor Security Fire Alarm Detection Panel
Automatic Indoor Security Fire Alarm Detection Panel
Automatic Indoor Security Fire Alarm Detection Panel
Automatic Indoor Security Fire Alarm Detection Panel

1. AW-CFP2166-16 conventional fire alarm panel is designed based on EN54 part 2 & 4 standard.
2. Adopted modularized design, flexible extendable capacity.
3. Two-level control mode by 2 locks.
4.27VDC power supply output.
5. FIRE PROTECTION, FIRE ROUTING and FAULT signal output, the output can be configured to dry relay type or wet sources type.
6.2 channel general sounders output.
7. Each zone has 1 circuit detectors input.
8. Each zone can be disable by a button.
9. RESET button to reset the panel.
10. SILENCE button to stop BUZZER and SOUNDERS.
11. EVACUATE button to start a manual fire alarm immediately.
12. TEST button to test all LEDs orderly.
13. Low-battery protection function, when battery voltage lower than 21VDC, battery will be cut off automatically until the mains power is on.
14. Optional GSM module is available for fire alarm by SMS.
Freeman Zhou
GSM: 008613922805315
Asenware, professional fire alarm solution provider.
ITEM1Zone panel2Zone panel4-8 Zone panel12-32 Zone panel
Model No.AW-CFP2166-01AW-CFP2166-02AW-CFP2166-04-8AW-CFP2166-12-32
Power specification
Mains supply voltage110VAC or 240VAC
Internal power supply27.2VDC
Total output current limited500mA @ 240VAC500mA @ 240VAC3A @ 240VAC3A @ 240VAC
Main supply monitor for faultYes
Battery protection for low voltageYes
Batteries (default configuration)12V2AH*2
Detector circuit specification
Number of circuit124-164-32
Line fault monitor for open circuitYes
Line fault monitor for short circuitYes
Line fault monitor for detector removalYes, if End of Line Monitor Unit fitted in place of End of Line Resistor
End of Line device6.8k Ω,5% tolerance, 0.25W (colour code-blue,grey,red,gold)
Detector continuity diodesSilicon 1N4001 or Schottky type (required if End of Line Monitor Unit fitted to give Detector Removal Fault)
Call point resistor value470 to 680 Ω, 0.225 or 0.5 watt
Maximum number of smoke/heat detectors per zone20 (based on a total detector current of 2mA, each detector consuming 100μA).Note: if End of Line Monitor Unit is fitted, for correct operation maxmum voltage drop must not exceed 12 volts.
Maximum number of manual call points per zoneNo limit
Sounder circuit specification
Number of general circuits2
End of line resistor value6.8k Ω,5% tolerance, 0.25W (colour code-blue,grey,red,gold)
Line fault monitor for open circuitYes
Line fault monitor for short circuitYes
Outputs fused AT400mA
Maximum number of bells @ 20mA of each sounder output20
Battery fuse1.5A F 20mm
Sounder outputs500mA F 20mm
Fire and fault output
Output typeNC and NO relay
Maximum current100mA
Connection block
Largest acceptable conductor size2.5mm2
Smallest acceptable conductor size0.75mm2
Size and weight

Weight (without batteries)4kg5kg7kg8kg
Weight (with batteries)5.8kg6.8kg9.6kg12.5kg

Send your message to this supplier

avatar Miss Julia

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now