2 Zone Conventional Fire Alarm Control Panel

Product Details
Customization: Available
Type: Industry Alarm
Signal Transmission: Wired Alarm
Still deciding? Get samples of US$ 75/Piece
Request Sample
Manufacturer/Factory, Trading Company

360° Virtual Tour

Diamond Member Since 2013

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
Fast Delivery
The supplier can deliver the goods within 30 days
Overseas Services
The supplier provides overseas services and supports countries including UK.

Overseas service content includes Debugging, Maintain, Repair, Training, Equipment Installation.
to see all verified strength labels (28)
  • 2 Zone Conventional Fire Alarm Control Panel
  • 2 Zone Conventional Fire Alarm Control Panel
  • 2 Zone Conventional Fire Alarm Control Panel
  • 2 Zone Conventional Fire Alarm Control Panel
  • 2 Zone Conventional Fire Alarm Control Panel
  • 2 Zone Conventional Fire Alarm Control Panel
Find Similar Products

Basic Info.

Model NO.
AW-CFP2166-2
Working Mode
Active
Application
Indoor, Outdoor
Working Principle
Electro-Optical Type
Transmission Mode
Cable
Alarm Volume (within 1m)
≥110dB
Receive Frequency
50Hz
Zones
1-32
Power Supply
110VAC/240VAC
Battery
12V2ah*2
Fire Relay Output
Nc and No
Fault Relay Output
Nc and No
Sounder Output
2 Circuits
Transport Package
EPE Inside, Carton Outside
Specification
8kg/pc
Trademark
Asenware
Origin
Guangdong, China
Production Capacity
10000PCS/Year

Product Description

 2 Zone Conventional Fire Alarm Control Panel 

Introduction:

1 AW-CFP2166 series conventional fire alarm panel is designed based on EN54 part 2&4 standard.
2 It is modularized design, the panel can expend from 1 zone to 32 zones easily.
3 It has 2 level control mode by a lock
4 It has 24VDC and 5VDC power supply output.
5 It has FIRE and FAULT signal output.
6 It has 2 general sounders output.
7 Each zone has 1 circuit detectors input.
8 Each zone can be disable by a button.
9 It has RESET button to reset the panel.
10 It has SILENCE button to stop BUZZER and SOUNDERS.
11 It has EVACUATE button to start a manual fire alarm immediately.
12 It has battery low protection function, when battery voltage lower than 21VDC, battery will be cut off automatically until the mains power is on.
13 It has an optional GSM module for fire alarm by SMS.
14 It is economic, user-friendly and easy maintenance.

Parameters:
ITEM 1Zone panel 2Zone panel 4-8 Zone panel 12-32 Zone panel
Model No. AW-CFP2166-01 AW-CFP2166-02 AW-CFP2166-04-8 AW-CFP2166-12-32
Power specification
 
Mains supply voltage 110VAC or 240VAC
Internal power supply 27.2VDC
Total output current limited 500mA @ 240VAC 500mA @ 240VAC 3A @ 240VAC 3A @ 240VAC
Main supply monitor for fault Yes
Battery protection for low voltage Yes
Batteries (default configuration) 12V2AH*2
Detector circuit specification
 
Number of circuit 1 2 4-16 4-32
Line fault monitor for open circuit Yes
Line fault monitor for short circuit Yes
Line fault monitor for detector removal Yes, if End of Line Monitor Unit fitted in place of End of Line Resistor
End of Line device 6.8k Ω,5% tolerance, 0.25W (colour code-blue,grey,red,gold)
Detector continuity diodes Silicon 1N4001 or Schottky type (required if End of Line Monitor Unit fitted to give Detector Removal Fault)
Call point resistor value 470 to 680 Ω, 0.225 or 0.5 watt
Maximum number of smoke/heat detectors per zone 20 (based on a total detector current of 2mA, each detector consuming 100μA).Note: if End of Line Monitor Unit is fitted, for correct operation maxmum voltage drop must not exceed 12 volts.
Maximum number of manual call points per zone No limit
Sounder circuit specification
 
Number of general circuits 2
End of line resistor value 6.8k Ω,5% tolerance, 0.25W (colour code-blue,grey,red,gold)
Line fault monitor for open circuit Yes
Line fault monitor for short circuit Yes
Outputs fused AT 400mA
Maximum number of bells @ 20mA of each sounder output 20
Fuses
 
Battery fuse 1.5A F 20mm
Sounder outputs 500mA F 20mm
Fire and fault output
 
Output type NC and NO relay
Maximum current 100mA
Connection block
 
Largest acceptable conductor size 2.5mm2
Smallest acceptable conductor size 0.75mm2
Size and weight
 

 
Dimensions(mm) 272*200*70mm 320*231*90mm 395X502X124 362X565X124
Weight (without batteries) 4kg 5kg 7kg 8kg
Weight (with batteries) 5.8kg 6.8kg 9.6kg 12.5kg
2 Zone Conventional Fire Alarm Control Panel
2 Zone Conventional Fire Alarm Control Panel
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier