Fire Trace Electrical Panel Protection System Price

Shenzhen Asenware Test and Control Technology Co., Ltd.
  • Audited Supplier
  • 14 yrs

Contact Supplier

Product Highlights

  • No Power Supply Required: Immune to vibration, dust, smoke, and electromagnetic interference.
  • Local Flooding Technology: Targets ignition sources directly, reducing agent use by over 80%.
  • Flexible Installation: Tube fits narrow spaces and complex equipment layouts easily.
  • Rapid Response Time: Discharges within 10 to 60 seconds depending on system type.
  • Environmentally Friendly: FM200 agent causes no secondary pollution or safety hazards.
  • Cost-Effective Design: Eliminates need for cabinets, power, and traditional alarm devices.

Product Images of Fire Trace Electrical Panel Protection System Price

Fire Trace Electrical Panel Protection System Price pictures & photos
Fire Trace Electrical Panel Protection System Price
Fire Trace Electrical Panel Protection System Price pictures & photos
Fire Trace Electrical Panel Protection System Price
Fire Trace Electrical Panel Protection System Price pictures & photos
Fire Trace Electrical Panel Protection System Price
Fire Trace Electrical Panel Protection System Price pictures & photos
Fire Trace Electrical Panel Protection System Price
Fire Trace Electrical Panel Protection System Price pictures & photos
Fire Trace Electrical Panel Protection System Price
Fire Trace Electrical Panel Protection System Price pictures & photos
Fire Trace Electrical Panel Protection System Price
  • Fire Trace Electrical Panel Protection System Price
    Fire Trace Electrical Panel Protection System Price
  • Fire Trace Electrical Panel Protection System Price
    Fire Trace Electrical Panel Protection System Price
  • Fire Trace Electrical Panel Protection System Price
    Fire Trace Electrical Panel Protection System Price
  • Fire Trace Electrical Panel Protection System Price
    Fire Trace Electrical Panel Protection System Price
  • Fire Trace Electrical Panel Protection System Price
    Fire Trace Electrical Panel Protection System Price
  • Fire Trace Electrical Panel Protection System Price
    Fire Trace Electrical Panel Protection System Price

Find Similar Products

Product Description

FM200 Tube type fire suppression
(hereinafter referred to as fire suppression System),
is a easy-use, low cost and high reliable and flexible system. Flexible fire detection tube can be easily placed closest to the potential ignition sources, in case of fire, the tube suffered heat burst and lost pressure, the fire detection System will be self-actuated automatically and the extinguishing agent will be sprayed out from the breakage of fire detection tube (releasing pipe for indirect type) for fire fighting.

The important advantages of this system are:
1. No need power supply and traditional fire alarm device, so reduce cost and installation difficulty, and
also will enhance its reliability to avoid accidental operation in the fire electronic alarm.
2. Traditional fixed extinguishing system which is detecting the whole protected space, will extinguish the fire by the way of total flooding and covering, no matter the fire behavior, which will slower the response time and cause huge waste of extinguishing agent.

The advantages of this system displayed as following:
1. Set alarm and extinguish into one, quick and effective detect fire, point-to-point fire extinguishing, fast
response, extinguishing the fire from the initial stage, reduce economic losses by fires.
2. No need power supply, not influenced by vibration and impact; the function of fire detection system will not be
influenced by oil, dust, smoke etc.;
3. Flexible fire-detect tube, can be placed anywhere at free choice, stretching into various narrow and small space
and equipment, which makes up for the existing defects of the current fire protection products.
4. Changing from traditional total flooding extinguishing in whole space to local flooding extinguishing aiming at
potential source of ignition, closest to the protected objects, this system has advantages as high efficient and
low cost.
5. The consumption of extinguishing-agent will be reduced more than 80%,more environmentally friendly, no
secondary pollution and more safety.
6. The best fit for unattended and key protected equipment and places.
7. Because of no power supply, the operation will not be influenced by electromagnetism, damp and hot
experiment, dust, so it is more safe and reliable to protect the electronic equipment.
8. Simple design, easy installation, no space occupation, no need to set up another fire extinguisher cabinet, low cost.

 
Model No.
AW-GSFT Series
Extinguishing agent
FM200(HFC-227ea)
Storage pressure(@20ºC)
1.6 MPa (Direct type)
2.5 MPa (Indirect type)
Minimum working temperature
1.1 MPa (Direct type)
2.0 MPa (Indirect type)
Maximum working temperature
3.4 MPa (Direct type)
4.2 MPa (Indirect type)
Discharging time
≤60s (Direct type)
≤10s (Indirect type)
Melting point temperature of
fire detection tube
160 ± 10ºC
Environmental
Temperature range: 0 to 50°C (32~122°F)
 
Technical Specification
 
 
Fire Trace Electrical Panel Protection System Price
Fire Trace Electrical Panel Protection System PriceFire Trace Electrical Panel Protection System PriceFire Trace Electrical Panel Protection System Price
Fire Trace Electrical Panel Protection System Price
Fire Trace Electrical Panel Protection System PriceFire Trace Electrical Panel Protection System PriceFire Trace Electrical Panel Protection System PriceFire Trace Electrical Panel Protection System PriceFire Trace Electrical Panel Protection System PriceFire Trace Electrical Panel Protection System PriceFire Trace Electrical Panel Protection System Price

About the Supplier

This supplier has been audited by CTI. Verify the report on the official CTI website with ID "QIP-ASR242972". Items marked "verified" are certified.

Shenzhen Asenware Test and Control Technology Co., Ltd.
Shenzhen Asenware Test and Control Technology Co., Ltd.
Shenzhen Asenware Test and Control Technology Co., Ltd.
Shenzhen Asenware Test and Control Technology Co., Ltd.
Shenzhen Asenware Test and Control Technology Co., Ltd.
Shenzhen Asenware Test and Control Technology Co., Ltd.
Shenzhen Asenware Test and Control Technology Co., Ltd.
Shenzhen Asenware Test and Control Technology Co., Ltd.

About Our Factory & Business Background

Address
4 / F, 10 Xingye Road, Torch Development Zone, Zhongshan, Guangdong, China
Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment, Money Gram
International Commercial Terms(Incoterms)
FOB, EXW, CIF
Average Lead Time
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays
Nearest Port
Zhongshan

Our Production Capability & Technical Expertise

Main Products
Fire Alarm System, Smoke Detector, Fire Alarm Control Panel, Fire Alarm, FM200, Fire Pump, Flame Detector, Fire Hose Reel, Emergency Light System, Beam Smoke Detector

Our Industry Experience & Global Business Record

Export Year
2005-06-01
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe

FAQ

Does the system require a power supply?
No, it operates without power, making it immune to electromagnetic interference and ensuring reliability.
What is the discharge time?
The system discharges within 60 seconds for direct type and 10 seconds for indirect type.
Is the system suitable for unattended areas?
Yes, it is ideal for unattended key equipment and places due to its self-actuating nature.
How much extinguishing agent is saved?
It reduces agent consumption by more than 80% compared to traditional total flooding systems.
Can the tube be installed in narrow spaces?
Yes, the flexible tube can be placed anywhere, including narrow and small spaces.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now