Public Address and Voice Alarm Voice Alarm Controller for 20 Emergency Trigger Input

Product Details
Customization: Available
Model: Aw-Evc100
Main Voltage: 100-260VAC ,50Hz/60Hz
Manufacturer/Factory, Trading Company

360° Virtual Tour

Diamond Member Since 2013

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

to see all verified strength labels (28)
  • Public Address and Voice Alarm Voice Alarm Controller for 20 Emergency Trigger Input
  • Public Address and Voice Alarm Voice Alarm Controller for 20 Emergency Trigger Input
  • Public Address and Voice Alarm Voice Alarm Controller for 20 Emergency Trigger Input
  • Public Address and Voice Alarm Voice Alarm Controller for 20 Emergency Trigger Input
  • Public Address and Voice Alarm Voice Alarm Controller for 20 Emergency Trigger Input
Find Similar Products

Basic Info.

Model NO.
AW-EVC100
Alarm Input
20 Channel
Remote Mic Communication
Can Bus
Slave Controller Communication
RS485 Bus
Transport Package
Cartoon
Specification
390*480*106.2mm
Trademark
Asenware
Origin
China
Production Capacity
1000 Pieces Per Month

Product Description

Product Description

AW-EVC100 Emergency Voice Evacuation Controller
 
Emergency voice evacuation controller is suitable for communication and dispatch in case of fire or emergency in the building. When a fire occurs in the application scene, the emergency evacuation audio will be played, and the on-site personnel can make a speaker call through the controller microphone to schedule the on-site evacuation.

Features
 
1.Maximum support 999 partitions
2.Maximum support 200 Paging
3.20 emergency trigger input
4.Multi-source selection(USB audio, Bluetooth audio, Paging, MICI, MIC2, AUXI, AUX2)
5.Each patition is individually on/off/isolation, partiton can be switched on when not isolated) Input trigger signals(including local trigger and fire panel trigger) freely map the emergency broadcast partiton
6.
Emergency broadcast supports delayed triggering
7.Set the number of emergency broadcast track loops
8.Paging priority settingIndividual volume control for each source
9.USB input import and export
10.History record
Public Address and Voice Alarm Voice Alarm Controller for 20 Emergency Trigger InputPublic Address and Voice Alarm Voice Alarm Controller for 20 Emergency Trigger InputPublic Address and Voice Alarm Voice Alarm Controller for 20 Emergency Trigger Input


Specification
 
Main Voltage 100-260VAC ,50HZ/60HZ
Standby Audio Output Balance 1V,<0.3% 1KHz
Battery Input Voltage and Current 24V DC±10%/3A
MIC input sensitivity and frequency response 10mV/80Hz~10KHz±3DB
AUX input sensitivity andfrequency response Unbalance,350mV/20Hz~20KHz±3DB
Paging Input Frequency response 20HZ-20KHZ±3DB
Alarm Input 20 channel
Remote MIC communication CAN bus


Certifications
Public Address and Voice Alarm Voice Alarm Controller for 20 Emergency Trigger Input
Company Profile


Who is ASENWARE?

ASENWARE is the fire alarm system and fire suppression system manufacturer and whole fire safety solution provider
since 2005. Driven by a commitment to sound operations, ongoing innovation, and open collaboration, we have established a competitive fire safety products line include addressable fire alarm system, conventional fire alarm system, central monitoring emergency light system, fire telephone and emergency audio system, fire pump, fire hose and gas suppression system. Our fire safety products ,solutions and services are used in over 100 countries. With over 200 employees work in United Kingdom-Marketing Center, China-R&D and Supply Chain Center and Bangladesh-Manufacture Center, ASENWARE is committed to design and manufacture the best fire safety products to reduce the risk of fire, and support the world to be more safe and more comfortable.
 
Public Address and Voice Alarm Voice Alarm Controller for 20 Emergency Trigger Input
Public Address and Voice Alarm Voice Alarm Controller for 20 Emergency Trigger Input


Overseas Projects
Public Address and Voice Alarm Voice Alarm Controller for 20 Emergency Trigger Input
Customer Photos
Public Address and Voice Alarm Voice Alarm Controller for 20 Emergency Trigger Input



Exhibitions
Public Address and Voice Alarm Voice Alarm Controller for 20 Emergency Trigger InputPublic Address and Voice Alarm Voice Alarm Controller for 20 Emergency Trigger Input

Our Services
Public Address and Voice Alarm Voice Alarm Controller for 20 Emergency Trigger InputPublic Address and Voice Alarm Voice Alarm Controller for 20 Emergency Trigger Input


FAQ

Q1: Are you manufacturer?
A: (yes)
Q2: What is the lead time
A: one week working day
Q3: How do you ship the goods and how long does it take arrive?
A: We usually ship by DHL, UPS, FedEx or by Air. 3-5 days after payment received.
Q4: Can I have a sample order?
A:Yes,we welcome sample order to test and check quality.
Q5: Do you offer OEM service?
A: Yes, we can design the things according to your request

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier