• Fire Alarm Addressable Smoke Detector Aw-Csd2188
  • Fire Alarm Addressable Smoke Detector Aw-Csd2188
  • Fire Alarm Addressable Smoke Detector Aw-Csd2188
  • Fire Alarm Addressable Smoke Detector Aw-Csd2188

Fire Alarm Addressable Smoke Detector Aw-Csd2188

Type: Heat Detector
Height: 2.2 Inch (55 Mm) Installed in Base
Diameter: 4.0 Inch (103 Mm)
Weight: 5.5 Oz. (155 G)
Opetating Voltage Range: 9 to 32 VDC Volts
Standby Current: ≤100µa @ 24 VDC
Customization:

Contact Supplier

Miss Christine Chen
Sales Director
Diamond Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
AW-CSD2188
Certificates
CE RoHS ISO9001
Wiring Method
2 Bus System Optical Smoke Detector
Design
OEM/ODM
Non-Polarized
Yes
Company Type
Fire Control Equipment Manufactor
Transport Package
Carton
Specification
CE
Trademark
Asenware
Origin
Guangdong, China
HS Code
8531100000
Production Capacity
2000000 Units/Year

Product Description

Fire Alarm Addressable Smoke Detector Aw-Csd2188

Fire Alarm Addressable Smoke Detector Aw-Csd2188
Fire Alarm Addressable Smoke Detector Aw-Csd2188

Product Description

Addressable Photoelectric Smoke Detector /smoke senser/fire alarm system
AW-ASD2188

FeaturesandTechnical parameters

1. Executive standard: GB4715-2005

2. Operating voltage: 24V (pulse modulation)

3. Operating current: < 300uA (monitoring status) or < 1.5mA (alarm status)

4. Work indication: The red indicator will blink in the monitoring status or remain lit in the alarm status. 

5. Weight: About 70g

6. External dimensions: Diameter: 100mm, height: 55mm (with the base)

7. Wiring method: Non-polarity two-bus system (L1, L2)

8. Operating environment: Indoor, temperature: -10° C~+55° C; Relative humidity: ≤ 95% (40° C± 2° C, without condensation)

9. Coding mode: It can realize electronic coding via coder in situ. Address codes 1 to 324 are available for selection. 

10. Installation height: ≤ 12m

11. Protection area: About 60m2. For details, see related provisions in GB50116-98 Code for Design of Automatic Fire Alarm System Matched host machine: Fire alarm control panel (such as AW-AFP2188)


Sensing Indoor Addressable Smoke Detector AW-ASD2188
Smoke Detector Basic Introduction
1. --Addressable smoke detector is a kind of photoelectric smoke detector. With an internal microprocessor. 
It supports electronic coding and is accessed through a compatible fire alarm control panel via a two-wire bus. 
2. --The detector realizes real-time acquisition of the in situ smoke concentration data
And sends back the data to a fire alarm control panel. 
3. --It can also receive and execute the control commands given by a fire alarm control panel.

Addressable Smoke Detector/Sensor/Alarm
 

Name
 

Addressable photoelectric smoke detector
 

Model
 

AW-ASD2188
 

External Specification
 

Diameter 100mm

Height 55mm (With Base)
 

Weight
 

70G
 

Matched

Host Machine
 

Addressable Fire Alarm Control Panel AW-AFP2188
 

Installation height
 

≤12m
 

Send your message to this supplier

*From:
*To:
avatar Miss Christine Chen
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now