Product Highlights

  • Addressable Photo-electronic Detection: Uses state-of-the-art optical sensing chamber for open area protection.
  • Wide Operating Voltage Range: Compatible with 9 to 28 VDC Non-Polarized power supply.
  • Compliance with EN Standards: Meets Standard Number Ref EN 57-7:2000 requirements.
  • Remote Indicator Support: Features 6 terminals including connections for remote indicators.
  • Manufacturer Experience: Asenware has been manufacturing fire alarm systems since 2005.

Product Images of Aw-D101 Asenware Addressable Smoke Detector Fire Alarm

Aw-D101 Asenware Addressable Smoke Detector Fire Alarm pictures & photos
Aw-D101 Asenware Addressable Smoke Detector Fire Alarm
Aw-D101 Asenware Addressable Smoke Detector Fire Alarm pictures & photos
Aw-D101 Asenware Addressable Smoke Detector Fire Alarm
Aw-D101 Asenware Addressable Smoke Detector Fire Alarm pictures & photos
Aw-D101 Asenware Addressable Smoke Detector Fire Alarm
Aw-D101 Asenware Addressable Smoke Detector Fire Alarm pictures & photos
Aw-D101 Asenware Addressable Smoke Detector Fire Alarm
Aw-D101 Asenware Addressable Smoke Detector Fire Alarm pictures & photos
Aw-D101 Asenware Addressable Smoke Detector Fire Alarm
Aw-D101 Asenware Addressable Smoke Detector Fire Alarm pictures & photos
Aw-D101 Asenware Addressable Smoke Detector Fire Alarm
  • Aw-D101 Asenware Addressable Smoke Detector Fire Alarm
    Aw-D101 Asenware Addressable Smoke Detector Fire Alarm
  • Aw-D101 Asenware Addressable Smoke Detector Fire Alarm
    Aw-D101 Asenware Addressable Smoke Detector Fire Alarm
  • Aw-D101 Asenware Addressable Smoke Detector Fire Alarm
    Aw-D101 Asenware Addressable Smoke Detector Fire Alarm
  • Aw-D101 Asenware Addressable Smoke Detector Fire Alarm
    Aw-D101 Asenware Addressable Smoke Detector Fire Alarm
  • Aw-D101 Asenware Addressable Smoke Detector Fire Alarm
    Aw-D101 Asenware Addressable Smoke Detector Fire Alarm
  • Aw-D101 Asenware Addressable Smoke Detector Fire Alarm
    Aw-D101 Asenware Addressable Smoke Detector Fire Alarm

Find Similar Products

Product Description

AW-D101 Asenware Addressable Smoke Detector Fire Alarm

Aw-D101 Asenware Addressable Smoke Detector Fire Alarm


Introduction

AW-D101 is addressable photo-electronic smoke detector uses a state of-the-art optical sensing chamber. This detector is designed to provide open area protection and to be used with most addressable fire alarm panel.

The addressable rate of rise of rise heat detector uses thermal component to detect the temperature changing in the environment. It can enable fire alam when the temperature difference achieved the setting rate of rise temperature value reach the setting fixed ualue. It has a stable and reliable working performance.

Two LEDs on each detector provide local 360° visible alarm indication. They flash every six seconds indicating that power is applied and the detector is working properly. The LEDs latch on in alarm. LEDs will be off when a trouble condition exists indicating that the detector sensitivity is outside the listed limit. The alarm can be reset only by a momentary power interruption.

The addressable detector that initiated the alarm condition will have its red LED and relays latched until reset by panel.

Model No. AW-D101
Operating Voltage Range 18V-28V DC  
Work Current ≤2.5mA
Temperature -10ºC to 50ºC
Smoke Sensitivity 0.2-0.3 dB/m
Standard Number Ref EN 57-7:2000
Terminals Connection No 6: Remote Indicator+   
No 3: Remote Indicator-
No 2: Loop IN+  
No 5: Loop IN-



Our company
Asenware, manufacturer of fire alarm and fire suppression system since 2005. Our headquarter is in London, UK, with factory Shenzhen, China
We keep our best service for our customers, and have a rich experienced engineer team to design and install for overseas projects.


Product range:
1. Addressable fire alarm system(FP100 series,2189,2100 series)
2. Conventional fire alarm system(2166 series)
3. FM200 gas fire suppression system
4. Emergency light system
5. Fire pump system
6. Fire hose and fire hose reel cabinet

Aw-D101 Asenware Addressable Smoke Detector Fire Alarm


Contact us
Asenware Ltd
 
Address:701, Bd 8, Dongfangming Industry Zone, Dabao Rd., Baoan, Shenzhen, China, Zip Code :518101
 

Company website: http://asenware.en.made-in-china.com

About the Supplier

This supplier has been audited by CTI. Verify the report on the official CTI website with ID "QIP-ASR242972". Items marked "verified" are certified.

Shenzhen Asenware Test and Control Technology Co., Ltd.
Shenzhen Asenware Test and Control Technology Co., Ltd.
Shenzhen Asenware Test and Control Technology Co., Ltd.
Shenzhen Asenware Test and Control Technology Co., Ltd.
Shenzhen Asenware Test and Control Technology Co., Ltd.
Shenzhen Asenware Test and Control Technology Co., Ltd.
Shenzhen Asenware Test and Control Technology Co., Ltd.
Shenzhen Asenware Test and Control Technology Co., Ltd.

About Our Factory & Business Background

Address
4 / F, 10 Xingye Road, Torch Development Zone, Zhongshan, Guangdong, China
Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment, Money Gram
International Commercial Terms(Incoterms)
FOB, EXW, CIF
Average Lead Time
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays
Nearest Port
Zhongshan

Our Production Capability & Technical Expertise

Main Products
Fire Alarm System, Smoke Detector, Fire Alarm Control Panel, Fire Alarm, FM200, Fire Pump, Flame Detector, Fire Hose Reel, Emergency Light System, Beam Smoke Detector

Our Industry Experience & Global Business Record

Export Year
2005-06-01
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe

FAQ

What is the operating voltage range?
The detector operates on a 9 to 28 VDC Non-Polarized range.
How does the detector indicate power status?
Two LEDs flash every six seconds to indicate power is applied and the detector is working properly.
What happens when a trouble condition exists?
The LEDs will turn off to indicate that the detector sensitivity is outside the listed limit.
How can the alarm be reset?
The alarm can only be reset by a momentary power interruption.
Which standard does this detector comply with?
It complies with Standard Number Ref EN 57-7:2000.
What is the lead time for orders?
The average lead time is within 15 workdays for both peak and off-peak seasons.