Kenya Hotel Conventional Fire Alarm System Solution 32 Zones

Shenzhen Asenware Test and Control Technology Co., Ltd.
  • Audited Supplier
  • 14 yrs

Contact Supplier

Product Highlights

  • EN54 Standard Compliance: Designed based on EN54 part 2 & 4 standards for reliable fire protection.
  • Modular Design: Flexible extendable capacity with options from 1 to 32 zones.
  • Multi-Zone Capacity: Available in 1, 2, 4-8, and 12-32 zone configurations.
  • Dual Sounder Circuits: Features 2 channel general sounders output with up to 20 bells per circuit.
  • Relay Output Options: Fire and fault signals configurable to dry relay (NC/NO) or wet source types.
  • Comprehensive Fault Monitoring: Monitors open circuit, short circuit, and detector removal with End of Line units.
  • Low-Battery Protection: Automatically cuts off battery when voltage drops below 21VDC until mains power returns.
  • Optional GSM Module: Supports SMS fire alarm notifications via optional GSM module.

Product Images of Kenya Hotel Conventional Fire Alarm System Solution 32 Zones

Kenya Hotel Conventional Fire Alarm System Solution 32 Zones pictures & photos
Kenya Hotel Conventional Fire Alarm System Solution 32 Zones
Kenya Hotel Conventional Fire Alarm System Solution 32 Zones pictures & photos
Kenya Hotel Conventional Fire Alarm System Solution 32 Zones
Kenya Hotel Conventional Fire Alarm System Solution 32 Zones pictures & photos
Kenya Hotel Conventional Fire Alarm System Solution 32 Zones
Kenya Hotel Conventional Fire Alarm System Solution 32 Zones pictures & photos
Kenya Hotel Conventional Fire Alarm System Solution 32 Zones
  • Kenya Hotel Conventional Fire Alarm System Solution 32 Zones
    Kenya Hotel Conventional Fire Alarm System Solution 32 Zones
  • Kenya Hotel Conventional Fire Alarm System Solution 32 Zones
    Kenya Hotel Conventional Fire Alarm System Solution 32 Zones
  • Kenya Hotel Conventional Fire Alarm System Solution 32 Zones
    Kenya Hotel Conventional Fire Alarm System Solution 32 Zones
  • Kenya Hotel Conventional Fire Alarm System Solution 32 Zones
    Kenya Hotel Conventional Fire Alarm System Solution 32 Zones

Find Similar Products

Product Description

Kenya Hotel Conventional Fire Alarm System Solution 32 Zones

Kenya Hotel Conventional Fire Alarm System Solution 32 Zones

ZHKenya Hotel Conventional Fire Alarm System Solution 32 ZonesIntroductions:

1. AW-CFP2166-8 conventional fire alarm panel is designed based on EN54 part 2 & 4 standard.
2. Adopted modularized design, flexible extendable capacity.
3. Two-level control mode by a lock
4.27VDC power supply output.
5. FIRE PROTECTION, FIRE ROUTING and FAULT signal output, the output can be configured to dry relay type or wet sources type.
6.2 channel general sounders output.
7. Each zone has 1 circuit detectors input.
8. Each zone can be disable by a button.
9. It has RESET button to reset the panel.
10. SILENCE button to stop BUZZER and SOUNDERS.
11. EVACUATE button to start a manual fire alarm immediately.
12. TEST button to test all LEDs orderly.
13. Low-battery protection function, when battery voltage lower than 21VDC, battery will be cut off automatically until the mains power is on.
14. Optional GSM module is available for fire alarm by SMS.
Freeman Zhou
GSM: 008613922805315

Asenware, professional fire alarm solution provider.
ITEM 1Zone panel 2Zone panel 4-8 Zone panel 12-32 Zone panel
Model No. AW-CFP2166-01 AW-CFP2166-02 AW-CFP2166-04-8 AW-CFP2166-12-32
Power specification
 
Mains supply voltage 110VAC or 240VAC
Internal power supply 27.2VDC
Total output current limited 500mA @ 240VAC 500mA @ 240VAC 3A @ 240VAC 3A @ 240VAC
Main supply monitor for fault Yes
Battery protection for low voltage Yes
Batteries (default configuration) 12V2AH*2
Detector circuit specification
 
Number of circuit 1 2 4-16 4-32
Line fault monitor for open circuit Yes
Line fault monitor for short circuit Yes
Line fault monitor for detector removal Yes, if End of Line Monitor Unit fitted in place of End of Line Resistor
End of Line device 6.8k Ω,5% tolerance, 0.25W (colour code-blue,grey,red,gold)
Detector continuity diodes Silicon 1N4001 or Schottky type (required if End of Line Monitor Unit fitted to give Detector Removal Fault)
Call point resistor value 470 to 680 Ω, 0.225 or 0.5 watt
Maximum number of smoke/heat detectors per zone 20 (based on a total detector current of 2mA, each detector consuming 100μA).Note: if End of Line Monitor Unit is fitted, for correct operation maxmum voltage drop must not exceed 12 volts.
Maximum number of manual call points per zone No limit
Sounder circuit specification
 
Number of general circuits 2
End of line resistor value 6.8k Ω,5% tolerance, 0.25W (colour code-blue,grey,red,gold)
Line fault monitor for open circuit Yes
Line fault monitor for short circuit Yes
Outputs fused AT 400mA
Maximum number of bells @ 20mA of each sounder output 20
Fuses
 
Battery fuse 1.5A F 20mm
Sounder outputs 500mA F 20mm
Fire and fault output
 
Output type NC and NO relay
Maximum current 100mA
Connection block
 
Largest acceptable conductor size 2.5mm2
Smallest acceptable conductor size 0.75mm2
Size and weight
 

 
Dimensions(mm) 272*200*70mm 320*231*90mm 395X502X124 362X565X124
Weight (without batteries) 4kg 5kg 7kg 8kg
Weight (with batteries) 5.8kg 6.8kg 9.6kg 12.5kg

About the Supplier

This supplier has been audited by CTI. Verify the report on the official CTI website with ID "QIP-ASR242972". Items marked "verified" are certified.

Shenzhen Asenware Test and Control Technology Co., Ltd.
Shenzhen Asenware Test and Control Technology Co., Ltd.
Shenzhen Asenware Test and Control Technology Co., Ltd.
Shenzhen Asenware Test and Control Technology Co., Ltd.
Shenzhen Asenware Test and Control Technology Co., Ltd.
Shenzhen Asenware Test and Control Technology Co., Ltd.
Shenzhen Asenware Test and Control Technology Co., Ltd.
Shenzhen Asenware Test and Control Technology Co., Ltd.

About Our Factory & Business Background

Address
4 / F, 10 Xingye Road, Torch Development Zone, Zhongshan, Guangdong, China
Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment, Money Gram
International Commercial Terms(Incoterms)
FOB, EXW, CIF
Average Lead Time
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays
Nearest Port
Zhongshan

Our Production Capability & Technical Expertise

Main Products
Fire Alarm System, Smoke Detector, Fire Alarm Control Panel, Fire Alarm, FM200, Fire Pump, Flame Detector, Fire Hose Reel, Emergency Light System, Beam Smoke Detector

Our Industry Experience & Global Business Record

Export Year
2005-06-01
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe

FAQ

What is the maximum number of detectors per zone?
The maximum number of smoke or heat detectors per zone is 20, based on a total detector current of 2mA.
Can the fire alarm system be expanded?
Yes, the system adopts a modularized design allowing flexible expansion from 1 zone up to 32 zones.
What are the available power supply options?
The system supports mains supply voltage of 110VAC or 240VAC with an internal power supply of 27.2VDC.
Does the system support manual alarm activation?
Yes, it includes an EVACUATE button to start a manual fire alarm immediately.
What is the alarm volume level?
The alarm volume is at least 110dB within 1 meter.
Is the system suitable for indoor fire projects?
Yes, the application is specified for indoor environments and fire projects.
What certifications does the product hold?
The product holds ISO and RoHS certifications.
What is the lead time for orders?
The average lead time is within 15 workdays for both peak and off-peak seasons.