Asenware 8-28VDC Conventional Photo-Electronic Sensor in Bedroom
Contact Supplier
Product Highlights
- LPCB EN54 Approved: Certified conventional photo-electronic smoke detector meeting EN 54-7:2000 standards.
- Wide Voltage Range: Operates on 9 to 28 VDC non-polarized power supply for flexible installation.
- Dual LED Indicators: Features two LEDs providing 360-degree visible alarm status and power indication.
- 1-Year Warranty: Comes with a comprehensive 1-year warranty covering mechanical defects.
- OEM & ODM Service: Offers customized manufacturing and design services for fire alarm systems.
- Fast Delivery: Ships within 3 to 5 days after payment is received via air, sea, or express.
Product Attributes
- Customization
- Available
- Type
- Smoke Detectors
- Anti-theft Alarm System Approach
- Active
- Anti-Theft Alarm System Type
- Smoke Alarms
- Anti-Theft Alarm System-Wide
- Wire Alarm Detectors
- Anti-Theft Alarm System Distance
- Power Detector
- Types of Smoke Detectors
- Photoelectric Smoke Style
- Infrared Sensor Probe Type
- Infrared Temperature Sensor
- Infrared Sensor Installation
- Ceiling
- Height
- 48.2mm Installed in Base
- Smoke Alarm Sensitivity
- 0.1-0.15dB/M
- Operating Temperature Range
- -10℃ to 50℃(14℉ to 122℉)
- Operating Voltage Range
- 9 to 28 VDC Non-Polarized
- Standby Current
- ≤120ua @ 24VDC
- Standard Number Ref
- En 54-7:2000
- Ec Certificate
- 0832-CPR-F2071
- Transport Package
- Carton Packing
- Specification
- 99.45mm
- Trademark
- ASENWARE
- Origin
- China
- Production Capacity
- 100, 000
Product Images of Asenware 8-28VDC Conventional Photo-Electronic Sensor in Bedroom
Find Similar Products
Product Description
LPCB EN54 APPROVED CONVENTIONAL SMOKE DETECTOR
AW-CSD381
AW-CSD381 is conventional photo-electronic smoke detector uses a state of-the-art optical sensing chamber.
This detector is designed to provide open area protection and to be used with most conventional fire alarm panel.
The conventional rate of rise of rise heat detector uses thermal component to detect the temperature changing in the
environment. It can enable fire alam when the temperature difference achieved the setting rate of rise temperature
value reach the setting fixed ualue. It has a stable and reliable working performance.
Two LEDs on each detector provide local 360° visible alarm indication. They flash every six seconds indicating that power
is applied and the detector is working properly. The LEDs latch on in alarm. LEDs will be off when a trouble condition exists
indicating that the detector sensitivity is outside the listed limit. The alarm can be reset only by a momentary power interruption.
The detector that initiated the alarm condition will have its red LED and relays latched until reset by panel.
FEATURES
PARAMETER
COMPANY
Asenware, manufacturer of fire alarm and fire suppression system since 2005. Our headquarter is in London, UK, with
factory Shenzhen, China.
We keep our best service for our customers,and have a rich experienced engineer team to design and install for overseas project.
Product range:
Addressable fire alarm system
Conventional fire alarm system (2166 series)
FM200 gas suppression system (2159 series)
Fire pump
Fire hose/hose reel and cabinet
Abc powder/co2 fire extinguisher
Emergency light system
CERTIFICATES
SERVICE
Ø OEM & ODM service: YES
Ø Technical support and After-sale service: YES
Ø Warranty: 1 YEAR
Ø Delivery Time: 3 - 5 days after payment received
Ø Shipping: delivery by air, ship or DHL, FEDX etc. Express for your order
CONTACT US
Rella Liang
AW-CSD381
AW-CSD381 is conventional photo-electronic smoke detector uses a state of-the-art optical sensing chamber.
This detector is designed to provide open area protection and to be used with most conventional fire alarm panel.
The conventional rate of rise of rise heat detector uses thermal component to detect the temperature changing in the
environment. It can enable fire alam when the temperature difference achieved the setting rate of rise temperature
value reach the setting fixed ualue. It has a stable and reliable working performance.
Two LEDs on each detector provide local 360° visible alarm indication. They flash every six seconds indicating that power
is applied and the detector is working properly. The LEDs latch on in alarm. LEDs will be off when a trouble condition exists
indicating that the detector sensitivity is outside the listed limit. The alarm can be reset only by a momentary power interruption.
The detector that initiated the alarm condition will have its red LED and relays latched until reset by panel.
FEATURES
| Operating Voltage Range | 9 to 28 VDC Non-polarized |
| Standby Current | ≤120uA@24VDC |
| Maximum Alarm Current (LED on) | ≤15mA@24VDC (1K Ohm current-limiting resistance) |
| Operating Humidity Range | ≤95%RH(40ºC±2ºC)RelativeHumidity,Non-condensing |
| Operating Temperature Range | -10ºC to 50ºC(14ºF to 122ºF) |
| Smoke Alarm Sensitivity | 0.1-0.15dB/m |
| Height | 48.2mm installed in Base |
| Diameter | 99.45mm |
| Standard Number ref | EN 54-7:2000 |
| EC certificate | 0832-CPR-F2071 |
PARAMETER
COMPANY
Asenware, manufacturer of fire alarm and fire suppression system since 2005. Our headquarter is in London, UK, with
factory Shenzhen, China.
We keep our best service for our customers,and have a rich experienced engineer team to design and install for overseas project.
Product range:
Addressable fire alarm system
Conventional fire alarm system (2166 series)
FM200 gas suppression system (2159 series)
Fire pump
Fire hose/hose reel and cabinet
Abc powder/co2 fire extinguisher
Emergency light system
CERTIFICATES
SERVICE
Ø OEM & ODM service: YES
Ø Technical support and After-sale service: YES
Ø Warranty: 1 YEAR
Ø Delivery Time: 3 - 5 days after payment received
Ø Shipping: delivery by air, ship or DHL, FEDX etc. Express for your order
CONTACT US
Rella Liang
About the Supplier
This supplier has been audited by CTI. Verify the report on the official CTI website with ID "QIP-ASR242972". Items marked "" are certified.
Company Profile
Company Information
ASENWARE is the fire alarm system and fire suppression system manufacturer and whole fire safety solution provilder since 2005. Driven by a commitment to sound operations, ongoing innovation, and open collaboration, we have established a competitive fire safety products line including addressable fire alarm system, conventional fire alarm system, central monitoring emergency light system, fire telephone and voice evacuation system, fire pump, fire hose and gas suppression system.
About Our Factory & Business Background
- Address
- 4 / F, 10 Xingye Road, Torch Development Zone, Zhongshan, Guangdong, China
- Terms of Payment
- LC, T/T, D/P, PayPal, Western Union, Small-amount payment, Money Gram
- International Commercial Terms(Incoterms)
- FOB, EXW, CIF
- Average Lead Time
-
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays - Nearest Port
- Zhongshan
Our Production Capability & Technical Expertise
Our Industry Experience & Global Business Record
- Export Year
- 2005-06-01
- Main Markets
- North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe
FAQ
- What is the operating voltage range?
- The detector operates on a 9 to 28 VDC non-polarized power supply.
- Does this smoke detector have a warranty?
- Yes, we provide a 1-year warranty for this product.
- Is OEM or ODM service available?
- Yes, we offer both OEM and ODM services for our fire alarm products.
- How long does it take to deliver the order?
- Delivery is typically completed within 3 to 5 days after payment is received.
- What certifications does the detector have?
- It is LPCB EN54 approved and meets the EN 54-7:2000 standard.
- Can the alarm be reset remotely?
- No, the alarm can only be reset by a momentary power interruption.
Send your message to this supplier
People who viewed this also viewed
-
US$100.00-110.00 / Piece
-
US$330.00 / Piece
-
US$13.00 / Piece
-
US$450.00-500.00 / Piece
-
US$6.00-8.00 / Piece
-
US$11.44-14.30 / Piece
-
US$306.00-385.00 / Piece
-
US$10.00-14.30 / Piece
-
US$12.16-14.30 / Piece
Find Similar Products By Category
- Supplier Homepage
- Products
- Fire Alarm System
- Two Wire Addressable Fire Alarm System
- Asenware 8-28VDC Conventional Photo-Electronic Sensor in Bedroom
Related Categories
Hot Searches
- Alarm Security Factories
- Alarm Sensor Factories
- Smoke System Factories
- Security Detector Factories
- Smoke Detector Alarm System
- Alarm Detector Smoke Sensor
- Smoke Co Detector Alarm
- Fire Smoke Detector System
- Smoke Detector Fire Alarm System
- Conventional Fire Alarm Smoke Detector Bulkbuy