Fire Security Items Fire Alarm Control System
Contact Supplier
Still deciding? Get samples of $ !
Request Sample
Product Highlights
- EN54 Standard Compliance: Designed based on EN54 part 2 & 4 standard for reliable fire protection.
- Modular Expandable Design: Flexible capacity extension from 1 to 32 zones with modularized structure.
- Customizable System Zones: Optional zones from 1-32 with max 20 detectors per zone configuration.
- Backup Power Supply: 24VDC backup battery provides 8 hours of consistent supply during power loss.
- Multi-Function Control Buttons: Includes RESET, SILENCE, EVACUATE, and TEST buttons for easy operation.
- Comprehensive Fault Monitoring: Monitors line faults, open/short circuits, and detector removal for safety.
- Optional GSM Module: Available GSM module enables fire alarm notifications via SMS.
Product Attributes
- Customization
- Available
- Type
- Industry Alarm
- Signal Transmission
- Wired Alarm
- Model NO.
- AW-CFP2166-16
- Working Mode
- Active
- Certification
- RoHS
- Application
- Indoor, Outdoor
- Working Principle
- Response to The Trigger Device
- Transmission Mode
- Cable
- Alarm Volume (within 1m)
- ≥110dB
- Receive Frequency
- Cable
- Optional Zones
- 1-32 / Max.20 Detectors/Zone
- Power Supply
- 110VAC/240VAC
- Backup Battery
- 24VDC/8 Hours Consistently Supply
- Fire Relay Output
- No/Nc
- Fault Relay Output
- No/Nc
- Sounder Output
- 2 Circuits
- Transport Package
- EPE Inside, Carton Outside
- Specification
- CE
- Trademark
- Asenware
- Origin
- Guangdong, China
- HS Code
- 853110000
- Production Capacity
- 10000PCS/Year
Product Images of Fire Security Items Fire Alarm Control System
Find Similar Products
Product Description
Fire Security Items Fire Alarm Control System
Introductions:
1. AW-CFP2166-2 conventional fire alarm panel is designed based on EN54 part 2 & 4 standard.
2. Adopted modularized design, flexible extendable capacity.
3. Two-level control mode by a lock
4.27VDC power supply output.
5. FIRE PROTECTION, FIRE ROUTING and FAULT signal output, the output can be configured to dry relay type or wet sources type.
6.2 channel general sounders output.
7. Each zone has 1 circuit detectors input.
8. Each zone can be disable by a button.
9. It has RESET button to reset the panel.
10. SILENCE button to stop BUZZER and SOUNDERS.
11. EVACUATE button to start a manual fire alarm immediately.
12. TEST button to test all LEDs orderly.
13. Low-battery protection function, when battery voltage lower than 21VDC, battery will be cut off automatically until the mains power is on.
14. Optional GSM module is available for fire alarm by SMS.
Asenware, professional fire alarm solution provider.
Introductions:
1. AW-CFP2166-2 conventional fire alarm panel is designed based on EN54 part 2 & 4 standard.
2. Adopted modularized design, flexible extendable capacity.
3. Two-level control mode by a lock
4.27VDC power supply output.
5. FIRE PROTECTION, FIRE ROUTING and FAULT signal output, the output can be configured to dry relay type or wet sources type.
6.2 channel general sounders output.
7. Each zone has 1 circuit detectors input.
8. Each zone can be disable by a button.
9. It has RESET button to reset the panel.
10. SILENCE button to stop BUZZER and SOUNDERS.
11. EVACUATE button to start a manual fire alarm immediately.
12. TEST button to test all LEDs orderly.
13. Low-battery protection function, when battery voltage lower than 21VDC, battery will be cut off automatically until the mains power is on.
14. Optional GSM module is available for fire alarm by SMS.
Asenware, professional fire alarm solution provider.
| ITEM | 1Zone panel | 2Zone panel | 4-8 Zone panel | 12-32 Zone panel |
| Model No. | AW-CFP2166-01 | AW-CFP2166-02 | AW-CFP2166-04-8 | AW-CFP2166-12-32 |
| Power specification | ||||
| Mains supply voltage | 110VAC or 240VAC | |||
| Internal power supply | 27.2VDC | |||
| Total output current limited | 500mA @ 240VAC | 500mA @ 240VAC | 3A @ 240VAC | 3A @ 240VAC |
| Main supply monitor for fault | Yes | |||
| Battery protection for low voltage | Yes | |||
| Batteries (default configuration) | 12V2AH*2 | |||
| Detector circuit specification | ||||
| Number of circuit | 1 | 2 | 4-16 | 4-32 |
| Line fault monitor for open circuit | Yes | |||
| Line fault monitor for short circuit | Yes | |||
| Line fault monitor for detector removal | Yes, if End of Line Monitor Unit fitted in place of End of Line Resistor | |||
| End of Line device | 6.8k Ω,5% tolerance, 0.25W (colour code-blue,grey,red,gold) | |||
| Detector continuity diodes | Silicon 1N4001 or Schottky type (required if End of Line Monitor Unit fitted to give Detector Removal Fault) | |||
| Call point resistor value | 470 to 680 Ω, 0.225 or 0.5 watt | |||
| Maximum number of smoke/heat detectors per zone | 20 (based on a total detector current of 2mA, each detector consuming 100μA).Note: if End of Line Monitor Unit is fitted, for correct operation maxmum voltage drop must not exceed 12 volts. | |||
| Maximum number of manual call points per zone | No limit | |||
| Sounder circuit specification | ||||
| Number of general circuits | 2 | |||
| End of line resistor value | 6.8k Ω,5% tolerance, 0.25W (colour code-blue,grey,red,gold) | |||
| Line fault monitor for open circuit | Yes | |||
| Line fault monitor for short circuit | Yes | |||
| Outputs fused AT | 400mA | |||
| Maximum number of bells @ 20mA of each sounder output | 20 | |||
| Fuses | ||||
| Battery fuse | 1.5A F 20mm | |||
| Sounder outputs | 500mA F 20mm | |||
| Fire and fault output | ||||
| Output type | NC and NO relay | |||
| Maximum current | 100mA | |||
| Connection block | ||||
| Largest acceptable conductor size | 2.5mm2 | |||
| Smallest acceptable conductor size | 0.75mm2 | |||
| Size and weight | ||||
| Dimensions(mm) | 272*200*70mm | 320*231*90mm | 395X502X124 | 362X565X124 |
| Weight (without batteries) | 4kg | 5kg | 7kg | 8kg |
| Weight (with batteries) | 5.8kg | 6.8kg | 9.6kg | 12.5kg |
About the Supplier
This supplier has been audited by CTI. Verify the report on the official CTI website with ID "QIP-ASR242972". Items marked "" are certified.
Company Profile
Company Information
ASENWARE is the fire alarm system and fire suppression system manufacturer and whole fire safety solution provilder since 2005. Driven by a commitment to sound operations, ongoing innovation, and open collaboration, we have established a competitive fire safety products line including addressable fire alarm system, conventional fire alarm system, central monitoring emergency light system, fire telephone and voice evacuation system, fire pump, fire hose and gas suppression system.
About Our Factory & Business Background
- Address
- 4 / F, 10 Xingye Road, Torch Development Zone, Zhongshan, Guangdong, China
- Terms of Payment
- LC, T/T, D/P, PayPal, Western Union, Small-amount payment, Money Gram
- International Commercial Terms(Incoterms)
- FOB, EXW, CIF
- Average Lead Time
-
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays - Nearest Port
- Zhongshan
Our Production Capability & Technical Expertise
Our Industry Experience & Global Business Record
- Export Year
- 2005-06-01
- Main Markets
- North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe
FAQ
- What standards does the fire alarm panel comply with?
- The AW-CFP2166-2 conventional fire alarm panel is designed based on EN54 part 2 & 4 standard.
- How many zones can the system support?
- The system supports optional zones from 1 to 32, with a maximum of 20 detectors per zone.
- What is the backup battery duration?
- The backup battery provides 24VDC and ensures consistently supply for 8 hours.
- Is an optional GSM module available?
- Yes, an optional GSM module is available for fire alarm by SMS.
- What are the power supply specifications?
- The power supply voltage is 110VAC or 240VAC, with an internal power supply of 27.2VDC.
- What control buttons are included?
- It includes RESET, SILENCE, EVACUATE, and TEST buttons for panel operation and testing.
- What fault monitoring features are included?
- It features line fault monitoring for open circuit, short circuit, and detector removal.
Send your message to this supplier
People who viewed this also viewed
-
US$98.00-118.00 / Piece
-
US$520.00-525.00 / Piece
-
US$66.81-78.60 / Piece
-
US$60.00-525.00 / Piece
-
US$11.55-16.50 / Piece
-
US$11.55-16.50 / Piece
-
US$11.55-16.50 / Piece
-
US$1,500.00-1,800.00 / Piece
-
US$8,075.00-8,550.00 / Piece
-
US$100.00-126.00 / Piece
Find Similar Products By Category
- Supplier Homepage
- Products
- Fire Alarm System etc
- Conventional Fire Alarm System
- Fire Security Items Fire Alarm Control System