Good Price Lpcb Approved Conventional Fire Alarm System for Fdas
Contact Supplier
Still deciding? Get samples of $ !
Request Sample
Product Highlights
- EN54 Compliance: Designed based on EN54 part 2&4 standard for conventional fire alarm systems.
- Modular Expansion: Easily expands from 1 zone to 32 zones with modularized design.
- Dual Power Supply: Supports 110VAC/240VAC mains with 24VDC and 5VDC output capabilities.
- Battery Protection: Automatic cut-off when voltage drops below 21VDC until mains power returns.
- Multiple Control Buttons: Features RESET, SILENCE, and EVACUATE buttons for immediate manual control.
- Flexible Zone Configuration: Basic unit offers 1-8 zones, scalable up to 16 or 32 zones for larger applications.
- Comprehensive Fault Monitoring: Monitors open circuits, short circuits, and detector removal with End of Line units.
- Optional GSM Module: Supports optional GSM module for fire alarm notifications via SMS.
Product Attributes
- Customization
- Available
- Type
- Fire Alarm
- Anti-theft Alarm System Approach
- Active
- Model NO.
- AW-CFP2166
- Anti-Theft Alarm System Type
- Smoke Alarms
- Anti-Theft Alarm System-Wide
- Wire Alarm Detectors
- Anti-Theft Alarm System Distance
- Power Detector
- Types of Smoke Detectors
- Photoelectric Smoke Style
- Infrared Sensor Probe Type
- Inclination Sensor
- Infrared Sensor Installation
- Ceiling
- Combustible Gas Detector Model
- NA-300
- Item
- Detection Control Panel
- Zones
- 1-32
- Power Supply
- 110VAC/240VAC
- Battery
- 12V2ah*2
- Fire Relay Output
- Nc and No
- Fault Relay Output
- Nc and No
- Sounder Output
- 2 Circuits
- Fob Port
- Shenzhen
- Delivery Time
- 15 Days
- Payment
- T/T, Western Union
- Transport Package
- EPE Inside, Carton Outside
- Specification
- CE
- Trademark
- Asenware
- Origin
- Guangdong, China
- Production Capacity
- 10000PCS/Year
Product Images of Good Price Lpcb Approved Conventional Fire Alarm System for Fdas
Find Similar Products
Product Description
1-32 zone conventional fire detection control panel
Introduction:
The AW-CFP2166 series conventional fire alarm panel is designed based on EN54 part 2&4 standard. And it is the central part of conventional fire alarm system, designed for applications requiring smoke detector, bell, manual pull stations, and sprinkler supervision. Each zone can be disabled by a button. The basic unit offers 1 to 8 zones of initiation, up to 16 zones for larger applications.
1 AW-CFP2166 series conventional fire alarm panel is designed based on EN54 part 2&4 standard.
2 It is modularized design, the panel can expend from 1 zone to 32 zones easily.
3 It has 2 level control mode by a lock
4 It has 24VDC and 5VDC power supply output.
5 It has FIRE and FAULT signal output.
6 It has 2 general sounders output.
7 Each zone has 1 circuit detectors input.
8 Each zone can be disable by a button.
9 It has RESET button to reset the panel.
10 It has SILENCE button to stop BUZZER and SOUNDERS.
11 It has EVACUATE button to start a manual fire alarm immediately.
12 It has battery low protection function, when battery voltage lower than 21VDC, battery will be cut off automatically until the mains power is on.
13 It has an optional GSM module for fire alarm by SMS.
14 It is economic, user-friendly and easy maintenance.
Parameters:
Show board for conventional fire alarm system
Company

Contact us
Swing Cao
Introduction:
The AW-CFP2166 series conventional fire alarm panel is designed based on EN54 part 2&4 standard. And it is the central part of conventional fire alarm system, designed for applications requiring smoke detector, bell, manual pull stations, and sprinkler supervision. Each zone can be disabled by a button. The basic unit offers 1 to 8 zones of initiation, up to 16 zones for larger applications.
1 AW-CFP2166 series conventional fire alarm panel is designed based on EN54 part 2&4 standard.
2 It is modularized design, the panel can expend from 1 zone to 32 zones easily.
3 It has 2 level control mode by a lock
4 It has 24VDC and 5VDC power supply output.
5 It has FIRE and FAULT signal output.
6 It has 2 general sounders output.
7 Each zone has 1 circuit detectors input.
8 Each zone can be disable by a button.
9 It has RESET button to reset the panel.
10 It has SILENCE button to stop BUZZER and SOUNDERS.
11 It has EVACUATE button to start a manual fire alarm immediately.
12 It has battery low protection function, when battery voltage lower than 21VDC, battery will be cut off automatically until the mains power is on.
13 It has an optional GSM module for fire alarm by SMS.
14 It is economic, user-friendly and easy maintenance.
Parameters:
| ITEM | 1Zone panel | 2Zone panel | 4-8 Zone panel | 12-32 Zone panel |
| Model No. | AW-CFP2166-01 | AW-CFP2166-02 | AW-CFP2166-04-8 | AW-CFP2166-12-32 |
| Power specification | ||||
| Mains supply voltage | 110VAC or 240VAC | |||
| Internal power supply | 27.2VDC | |||
| Total output current limited | 500mA @ 240VAC | 500mA @ 240VAC | 3A @ 240VAC | 3A @ 240VAC |
| Main supply monitor for fault | Yes | |||
| Battery protection for low voltage | Yes | |||
| Batteries (default configuration) | 12V2AH*2 | |||
| Detector circuit specification | ||||
| Number of circuit | 1 | 2 | 4-16 | 4-32 |
| Line fault monitor for open circuit | Yes | |||
| Line fault monitor for short circuit | Yes | |||
| Line fault monitor for detector removal | Yes, if End of Line Monitor Unit fitted in place of End of Line Resistor | |||
| End of Line device | 6.8k Ω,5% tolerance, 0.25W (colour code-blue,grey,red,gold) | |||
| Detector continuity diodes | Silicon 1N4001 or Schottky type (required if End of Line Monitor Unit fitted to give Detector Removal Fault) | |||
| Call point resistor value | 470 to 680 Ω, 0.225 or 0.5 watt | |||
| Maximum number of smoke/heat detectors per zone | 20 (based on a total detector current of 2mA, each detector consuming 100μA).Note: if End of Line Monitor Unit is fitted, for correct operation maxmum voltage drop must not exceed 12 volts. | |||
| Maximum number of manual call points per zone | No limit | |||
| Sounder circuit specification | ||||
| Number of general circuits | 2 | |||
| End of line resistor value | 6.8k Ω,5% tolerance, 0.25W (colour code-blue,grey,red,gold) | |||
| Line fault monitor for open circuit | Yes | |||
| Line fault monitor for short circuit | Yes | |||
| Outputs fused AT | 400mA | |||
| Maximum number of bells @ 20mA of each sounder output | 20 | |||
| Fuses | ||||
| Battery fuse | 1.5A F 20mm | |||
| Sounder outputs | 500mA F 20mm | |||
| Fire and fault output | ||||
| Output type | NC and NO relay | |||
| Maximum current | 100mA | |||
| Connection block | ||||
| Largest acceptable conductor size | 2.5mm2 | |||
| Smallest acceptable conductor size | 0.75mm2 | |||
| Size and weight | ||||
| Dimensions(mm) | 272*200*70mm | 320*231*90mm | 395X502X124 | 362X565X124 |
| Weight (without batteries) | 4kg | 5kg | 7kg | 8kg |
| Weight (with batteries) | 5.8kg | 6.8kg | 9.6kg | 12.5kg |
Show board for conventional fire alarm system
Company

Contact us
Swing Cao
About the Supplier
This supplier has been audited by CTI. Verify the report on the official CTI website with ID "QIP-ASR242972". Items marked "" are certified.
Company Profile
Company Information
ASENWARE is the fire alarm system and fire suppression system manufacturer and whole fire safety solution provilder since 2005. Driven by a commitment to sound operations, ongoing innovation, and open collaboration, we have established a competitive fire safety products line including addressable fire alarm system, conventional fire alarm system, central monitoring emergency light system, fire telephone and voice evacuation system, fire pump, fire hose and gas suppression system.
About Our Factory & Business Background
- Address
- 4 / F, 10 Xingye Road, Torch Development Zone, Zhongshan, Guangdong, China
- Terms of Payment
- LC, T/T, D/P, PayPal, Western Union, Small-amount payment, Money Gram
- International Commercial Terms(Incoterms)
- FOB, EXW, CIF
- Average Lead Time
-
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays - Nearest Port
- Zhongshan
Our Production Capability & Technical Expertise
Our Industry Experience & Global Business Record
- Export Year
- 2005-06-01
- Main Markets
- North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe
FAQ
- What is the maximum number of zones supported?
- The panel supports modular expansion from 1 zone up to 32 zones.
- What power supply voltage does the system require?
- It accepts 110VAC or 240VAC mains supply and provides 24VDC and 5VDC outputs.
- How does the battery protection work?
- If battery voltage drops below 21VDC, the battery cuts off automatically until mains power is restored.
- Can individual zones be disabled?
- Yes, each zone can be disabled individually by a button.
- What types of detectors can be connected?
- It supports smoke detectors, heat detectors, and manual call points with up to 20 detectors per zone.
- Is there an option for remote notification?
- Yes, an optional GSM module is available to send fire alarm alerts via SMS.
- What are the lead times for delivery?
- The average lead time is within 15 workdays for both peak and off-peak seasons.
- What payment methods are accepted?
- Accepted methods include LC, T/T, D/P, PayPal, Western Union, Small-amount payment, and Money Gram.
Send your message to this supplier
People who viewed this also viewed
-
US$17.00-18.00 / Piece
-
US$11.44-14.30 / Piece
-
US$330.00 / Piece
-
US$13.00 / Piece
-
US$450.00-500.00 / Piece
-
US$15.00-20.00 / Piece
-
US$6.00-8.00 / Piece
-
US$11.44-14.30 / Piece
-
US$306.00-385.00 / Piece
Find Similar Products By Category
- Supplier Homepage
- Products
- Fire Alarm System etc
- Conventional Fire Alarm System
- Good Price Lpcb Approved Conventional Fire Alarm System for Fdas
Related Categories
Hot Searches
- Fire System
- Alarm Control System Factories
- Fire Security Factories
- Fire Fighting System
- CE Fire Alarm Control
- Fire Alarm Gas
- Fire Alarm System Panel
- Led Fire Alarm
- Conventional Fire Alarm System
- Fire Alarm System Bulkbuy