Guangdong, China
Business Type:
Manufacturer/Factory, Trading Company
Plant Area:
>2000 square meters
Management System Certification:
ISO 9001
Terms of Payment:
LC, T/T, D/P, PayPal, Western Union, Small-amount payment, Money Gram
OEM/ODM Availability:
OEM/ODM Service
Sample Available
Overseas Agent / Branch

Fire Alarm, Fire Alarm Control Panel, Fire Control manufacturer / supplier in China, offering Conventional Fire Alarm Control Panel for Building Project, Fire Security Control Panel Host Conventional Alarm, Wired Addressable Control Panel Fire Alarm System and so on.

Gold Member Since 2013
Audited Supplier

Conventional Fire Alarm Control Panel for Building Project

Get Latest Price
Min. Order / Reference FOB Price
1 Piece US $60/ Piece
Port: Shenzhen, China
Production Capacity: 10000PCS/Year
Payment Terms: T/T, Western Union, Paypal
Type: Fire Alarm
Zones: 1-32
Mains Supply Voltage: 110VAC/240VAC
Internal Power Supply: 27.2VDC
Total Output Current Limited: 3A @ 240VAC
Main Supply Monitor for Fault: Yes

You Might Also Like


Basic Info

Model NO.: AW-CFP2166
Battery Protection for Low Voltage: Yes
Batteries (Default Configuration): 12V2ah*2
Number of Circuit: 12V2ah*2
Number of General Circuits: 2
Material: Stainless Steel
Trademark: Asenware
Transport Package: EPE Inside, Carton Outside
Specification: CE
Origin: Guangdong, China

Product Description

1. Strictly in accordance with the EN54 part 2&4 standard.
2. Modularized design with extendable zones from 1 to 32 zones.
3. With two-level control modes by lock
4. 24VDC & 5VDC power supply outputs.
5. FIRE &  FAULT signal outputs.
6. Owns 2 general sounders outputs.
7. Each zone has 1 circuit detectors input .
8. Each zone can be disable by a button.
9. RESET button available
10.SILENCE button to stop BUZZER and SOUNDERS.
11. EVACUATE button to start a manual fire alarm immediately.
12.Low-battery level protection function, i.e., battery voltage lower than 21VDC, battery will be cut off automatically until the mains power is on.
13.GSM module for fire alarm by SMS is optional.
14 Economic, user-friendly & convenient maintenance.

Conventional Fire Alarm Control Panel for Building Project

Conventional Fire Alarm Control Panel for Building Project

Packaging & Shipping

As the pics shows:
Conventional Fire Alarm Control Panel for Building Project
ITEM1Zone panel2Zone panel4-8 Zone panel12-32 Zone panel
Model No.AW-CFP2166-01AW-CFP2166-02AW-CFP2166-04-8AW-CFP2166-12-32
Power specification
Mains supply voltage110VAC or 240VAC
Internal power supply27.2VDC
Total output current limited500mA @ 240VAC500mA @ 240VAC3A @ 240VAC3A @ 240VAC
Main supply monitor for faultYes
Battery protection for low voltageYes
Batteries (default configuration)12V2AH*2
Detector circuit specification
Number of circuit124-164-32
Line fault monitor for open circuitYes
Line fault monitor for short circuitYes
Line fault monitor for detector removalYes, if End of Line Monitor Unit fitted in place of End of Line Resistor
End of Line device6.8k Ω,5% tolerance, 0.25W (colour code-blue,grey,red,gold)
Detector continuity diodesSilicon 1N4001 or Schottky type (required if End of Line Monitor Unit fitted to give Detector Removal Fault)
Call point resistor value470 to 680 Ω, 0.225 or 0.5 watt
Maximum number of smoke/heat detectors per zone20 (based on a total detector current of 2mA, each detector consuming 100μA).Note: if End of Line Monitor Unit is fitted, for correct operation maxmum voltage drop must not exceed 12 volts.
Maximum number of manual call points per zoneNo limit
Sounder circuit specification
Number of general circuits2
End of line resistor value6.8k Ω,5% tolerance, 0.25W (colour code-blue,grey,red,gold)
Line fault monitor for open circuitYes
Line fault monitor for short circuitYes
Outputs fused AT400mA
Maximum number of bells @ 20mA of each sounder output20
Battery fuse1.5A F 20mm
Sounder outputs500mA F 20mm
Fire and fault output
Output typeNC and NO relay
Maximum current100mA
Connection block
Largest acceptable conductor size2.5mm2
Smallest acceptable conductor size0.75mm2
Size and weight

Weight (without batteries)4kg5kg7kg8kg
Weight (with batteries)5.8kg6.8kg9.6kg12.5kg

Company Information

Asenware,manufacturer of fire alarm and fire suppression system since 2005. 
Our headquarter is in London, UK, with factory Shenzhen, China.

We keep our best service for our customers, and have a rich experienced engineer team to design and install 
for overseas project.

Product range

Addressable fire alarm system
Conventional fire alarm system (2166 series)
FM200 gas suppression system (2159 series)
Fire pump
Fire hose/ hose reel and cabinet
ABC powder/ CO2 fire extinguisher
Emergency light system

Conventional Fire Alarm Control Panel for Building Project

Conventional Fire Alarm Control Panel for Building Project


Conventional Fire Alarm Control Panel for Building Project


Send your message to this supplier

avatar Ms. Amy

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now