Asenware Manufacturer Conventional Fire Alarm Complete System Panel for Buildings
Contact Supplier
Product Highlights
- EN54 Compliance: Strictly adheres to EN54 Part 2 & 4 standards for safety and reliability.
- Expandable Zones: Modular design supports extendable zones ranging from 1 to 32.
- Dual Control Modes: Features two-level control modes with lock functionality for enhanced security.
- Multiple Power Outputs: Provides 24VDC and 5VDC power supply outputs for connected devices.
- Comprehensive Monitoring: Includes line fault monitoring for open circuits, short circuits, and detector removal.
- Battery Protection: Automatic battery cutoff when voltage drops below 21VDC until mains power resumes.
- Manual Control Buttons: Equipped with RESET, SILENCE, and EVACUATE buttons for immediate manual intervention.
- Relay Signal Outputs: Offers FIRE & FAULT signal outputs with NC and NO relay types.
Product Attributes
- Customization
- Available
- Type
- Smoke Detectors
- Anti-theft Alarm System Approach
- Active
- Model NO.
- AW-CFP2166
- Anti-Theft Alarm System Type
- Smoke Alarms
- Anti-Theft Alarm System-Wide
- Wire Alarm Detectors
- Anti-Theft Alarm System Distance
- Common Detectors
- Types of Smoke Detectors
- Photoelectric Smoke Style
- Infrared Sensor Probe Type
- Infrared Temperature Sensor
- Infrared Sensor Installation
- Ceiling
- Zones
- 1-32
- Mains Supply Voltage
- 110VAC/240VAC
- Internal Power Supply
- 27.2VDC
- Total Output Current Limited
- 3A @ 240VAC
- Main Supply Monitor for Fault
- Yes
- Battery Protection for Low Voltage
- Yes
- Batteries (Default Configuration)
- 12V2ah*2
- Number of Circuit
- 12V2ah*2
- Number of General Circuits
- 2
- Material
- Stainless Steel
- Transport Package
- EPE Inside, Carton Outside
- Specification
- CE
- Trademark
- Asenware
- Origin
- Guangdong, China
- Production Capacity
- 10000PCS/Year
Product Images of Asenware Manufacturer Conventional Fire Alarm Complete System Panel for Buildings
Find Similar Products
Product Description
Conventional factory fire alarm system
Introduce:
1. Strictly in accordance with the EN54 part 2&4 standard.
Introduce:
1. Strictly in accordance with the EN54 part 2&4 standard.
2. Modularized design with extendable zones from 1 to 32 zones.
3. With two-level control modes by lock
4. 24VDC & 5VDC power supply outputs.
5. FIRE & FAULT signal outputs.
6. Owns 2 general sounders outputs.
7. Each zone has 1 circuit detectors input .
8. Each zone can be disable by a button.
9. RESET button available
10.SILENCE button to stop BUZZER and SOUNDERS.
11. EVACUATE button to start a manual fire alarm immediately.
12.Low-battery level protection function, i.e., battery voltage lower than 21VDC, battery will be cut off automatically until the mains power is on.
13.GSM module for fire alarm by SMS is optional.
14 Economic, user-friendly & convenient maintenance.

Packaging & Shipping
As the pics shows:

Packaging & Shipping
As the pics shows:
| ITEM | 1Zone panel | 2Zone panel | 4-8 Zone panel | 12-32 Zone panel |
| Model No. | AW-CFP2166-01 | AW-CFP2166-02 | AW-CFP2166-04-8 | AW-CFP2166-12-32 |
| Power specification | ||||
| Mains supply voltage | 110VAC or 240VAC | |||
| Internal power supply | 27.2VDC | |||
| Total output current limited | 500mA @ 240VAC | 500mA @ 240VAC | 3A @ 240VAC | 3A @ 240VAC |
| Main supply monitor for fault | Yes | |||
| Battery protection for low voltage | Yes | |||
| Batteries (default configuration) | 12V2AH*2 | |||
| Detector circuit specification | ||||
| Number of circuit | 1 | 2 | 4-16 | 4-32 |
| Line fault monitor for open circuit | Yes | |||
| Line fault monitor for short circuit | Yes | |||
| Line fault monitor for detector removal | Yes, if End of Line Monitor Unit fitted in place of End of Line Resistor | |||
| End of Line device | 6.8k Ω,5% tolerance, 0.25W (colour code-blue,grey,red,gold) | |||
| Detector continuity diodes | Silicon 1N4001 or Schottky type (required if End of Line Monitor Unit fitted to give Detector Removal Fault) | |||
| Call point resistor value | 470 to 680 Ω, 0.225 or 0.5 watt | |||
| Maximum number of smoke/heat detectors per zone | 20 (based on a total detector current of 2mA, each detector consuming 100μA).Note: if End of Line Monitor Unit is fitted, for correct operation maxmum voltage drop must not exceed 12 volts. | |||
| Maximum number of manual call points per zone | No limit | |||
| Sounder circuit specification | ||||
| Number of general circuits | 2 | |||
| End of line resistor value | 6.8k Ω,5% tolerance, 0.25W (colour code-blue,grey,red,gold) | |||
| Line fault monitor for open circuit | Yes | |||
| Line fault monitor for short circuit | Yes | |||
| Outputs fused AT | 400mA | |||
| Maximum number of bells @ 20mA of each sounder output | 20 | |||
| Fuses | ||||
| Battery fuse | 1.5A F 20mm | |||
| Sounder outputs | 500mA F 20mm | |||
| Fire and fault output | ||||
| Output type | NC and NO relay | |||
| Maximum current | 100mA | |||
| Connection block | ||||
| Largest acceptable conductor size | 2.5mm2 | |||
| Smallest acceptable conductor size | 0.75mm2 | |||
| Size and weight | ||||
| Dimensions(mm) | 272*200*70mm | 320*231*90mm | 395X502X124 | 362X565X124 |
| Weight (without batteries) | 4kg | 5kg | 7kg | 8kg |
| Weight (with batteries) | 5.8kg | 6.8kg | 9.6kg | 12.5kg |
Company Information
Asenware,manufacturer of fire alarm and fire suppression system since 2005.
Our headquarter is in London, UK, with factory Shenzhen, China.
We keep our best service for our customers, and have a rich experienced engineer team to design and install
for overseas project.
Product range
Addressable fire alarm system
Conventional fire alarm system (2166 series)
FM200 gas suppression system (2159 series)
Fire pump
Fire hose/ hose reel and cabinet
ABC powder/ CO2 fire extinguisher
Emergency light system
Certificates
Contact
About the Supplier
This supplier has been audited by CTI. Verify the report on the official CTI website with ID "QIP-ASR242972". Items marked "" are certified.
Company Profile
Company Information
ASENWARE is the fire alarm system and fire suppression system manufacturer and whole fire safety solution provilder since 2005. Driven by a commitment to sound operations, ongoing innovation, and open collaboration, we have established a competitive fire safety products line including addressable fire alarm system, conventional fire alarm system, central monitoring emergency light system, fire telephone and voice evacuation system, fire pump, fire hose and gas suppression system.
About Our Factory & Business Background
- Address
- 4 / F, 10 Xingye Road, Torch Development Zone, Zhongshan, Guangdong, China
- Terms of Payment
- LC, T/T, D/P, PayPal, Western Union, Small-amount payment, Money Gram
- International Commercial Terms(Incoterms)
- FOB, EXW, CIF
- Average Lead Time
-
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays - Nearest Port
- Zhongshan
Our Production Capability & Technical Expertise
Our Industry Experience & Global Business Record
- Export Year
- 2005-06-01
- Main Markets
- North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe
FAQ
- What standards does this fire alarm system comply with?
- The system is strictly designed in accordance with EN54 Part 2 & 4 standards.
- How many zones can the system support?
- It features a modular design with extendable zones ranging from 1 to 32.
- What are the power supply specifications?
- It accepts 110VAC or 240VAC mains supply, with internal 27.2VDC and outputs of 24VDC & 5VDC.
- Does the system have battery protection features?
- Yes, it automatically cuts off the battery if voltage drops below 21VDC until mains power is restored.
- What manual control functions are available?
- The panel includes RESET, SILENCE, and EVACUATE buttons for manual fire alarm activation and sounder control.
- Can the GSM module be added?
- Yes, a GSM module for fire alarm via SMS is available as an optional feature.
- What is the maximum number of detectors per zone?
- Each zone can support a maximum of 20 smoke or heat detectors based on current consumption.
- What is the lead time for orders?
- The average lead time is within 15 workdays for both peak and off-peak seasons.
Send your message to this supplier
People who viewed this also viewed
-
US$17.00-18.00 / Piece
-
US$11.44-14.30 / Piece
-
US$330.00 / Piece
-
US$13.00 / Piece
-
US$450.00-500.00 / Piece
-
US$15.00-20.00 / Piece
-
US$6.00-8.00 / Piece
-
US$11.44-14.30 / Piece
-
US$306.00-385.00 / Piece
Find Similar Products By Category
- Supplier Homepage
- Products
- Fire Alarm System etc
- Conventional Fire Alarm System
- Asenware Manufacturer Conventional Fire Alarm Complete System Panel for Buildings
Related Categories
Hot Searches
- Fire System
- Alarm Control System Factories
- Fire Fighting System
- Fire Alarm System Factories
- Fire Alarm Panel Factories
- Fire Security Alarm
- Fire Alarm Control
- Fire Alarm Control System
- Alarm Fire Door
- Factory Fire Alarm System Bulkbuy