Optional 32-Zone Security Fire Home Alarm System

Shenzhen Asenware Test and Control Technology Co., Ltd.
  • Audited Supplier
  • 14 yrs

Contact Supplier

Still deciding? Get samples of $ !
Request Sample

Product Highlights

  • EN54 Standard Compliance: Designed based on EN54 part 2 & 4 standard for reliable fire protection.
  • Modular Flexible Design: Modularized design allows flexible extendable capacity from 1 to 32 zones.
  • Multi-Function Control: Features FIRE PROTECTION, FIRE ROUTING, and FAULT signal outputs with configurable relay types.
  • Dual Sounder Circuits: Equipped with 2 channel general sounders output for effective alarm signaling.
  • Comprehensive Safety Buttons: Includes RESET, SILENCE, EVACUATE, and TEST buttons for full panel control.
  • Low-Battery Protection: Automatically cuts off battery when voltage drops below 21VDC until mains power returns.
  • Optional GSM Module: GSM module available for SMS fire alarm notifications.
  • Advanced Fault Monitoring: Monitors line faults for open circuit, short circuit, and detector removal.

Product Images of Optional 32-Zone Security Fire Home Alarm System

Optional 32-Zone Security Fire Home Alarm System pictures & photos
Optional 32-Zone Security Fire Home Alarm System
Optional 32-Zone Security Fire Home Alarm System pictures & photos
Optional 32-Zone Security Fire Home Alarm System
Optional 32-Zone Security Fire Home Alarm System pictures & photos
Optional 32-Zone Security Fire Home Alarm System
Optional 32-Zone Security Fire Home Alarm System pictures & photos
Optional 32-Zone Security Fire Home Alarm System
Optional 32-Zone Security Fire Home Alarm System pictures & photos
Optional 32-Zone Security Fire Home Alarm System
Optional 32-Zone Security Fire Home Alarm System pictures & photos
Optional 32-Zone Security Fire Home Alarm System
  • Optional 32-Zone Security Fire Home Alarm System
    Optional 32-Zone Security Fire Home Alarm System
  • Optional 32-Zone Security Fire Home Alarm System
    Optional 32-Zone Security Fire Home Alarm System
  • Optional 32-Zone Security Fire Home Alarm System
    Optional 32-Zone Security Fire Home Alarm System
  • Optional 32-Zone Security Fire Home Alarm System
    Optional 32-Zone Security Fire Home Alarm System
  • Optional 32-Zone Security Fire Home Alarm System
    Optional 32-Zone Security Fire Home Alarm System
  • Optional 32-Zone Security Fire Home Alarm System
    Optional 32-Zone Security Fire Home Alarm System

Find Similar Products

Product Description

Optional 32-Zone Security Fire Home Alarm System
Optional 32-Zone Security Fire Home Alarm System


Introductions:
1. AW-CFP2166-2 conventional fire alarm panel is designed based on EN54 part 2 & 4 standard.
2. Adopted modularized design, flexible extendable capacity.
3. Two-level control mode by a lock
4.27VDC power supply output.
5. FIRE PROTECTION, FIRE ROUTING and FAULT signal output, the output can be configured to dry relay type or wet sources type.
6.2 channel general sounders output.
7. Each zone has 1 circuit detectors input.
8. Each zone can be disable by a button.
9. It has RESET button to reset the panel.
10. SILENCE button to stop BUZZER and SOUNDERS.
11. EVACUATE button to start a manual fire alarm immediately.
12. TEST button to test all LEDs orderly.
13. Low-battery protection function, when battery voltage lower than 21VDC, battery will be cut off automatically until the mains power is on.
14. Optional GSM module is available for fire alarm by SMS.
Asenware, professional fire alarm solution provider.
ITEM 1Zone panel 2Zone panel 4-8 Zone panel 12-32 Zone panel
Model No. AW-CFP2166-01 AW-CFP2166-02 AW-CFP2166-04-8 AW-CFP2166-12-32
Power specification
 
Mains supply voltage 110VAC or 240VAC
Internal power supply 27.2VDC
Total output current limited 500mA @ 240VAC 500mA @ 240VAC 3A @ 240VAC 3A @ 240VAC
Main supply monitor for fault Yes
Battery protection for low voltage Yes
Batteries (default configuration) 12V2AH*2
Detector circuit specification
 
Number of circuit 1 2 4-16 4-32
Line fault monitor for open circuit Yes
Line fault monitor for short circuit Yes
Line fault monitor for detector removal Yes, if End of Line Monitor Unit fitted in place of End of Line Resistor
End of Line device 6.8k Ω,5% tolerance, 0.25W (colour code-blue,grey,red,gold)
Detector continuity diodes Silicon 1N4001 or Schottky type (required if End of Line Monitor Unit fitted to give Detector Removal Fault)
Call point resistor value 470 to 680 Ω, 0.225 or 0.5 watt
Maximum number of smoke/heat detectors per zone 20 (based on a total detector current of 2mA, each detector consuming 100μA).Note: if End of Line Monitor Unit is fitted, for correct operation maxmum voltage drop must not exceed 12 volts.
Maximum number of manual call points per zone No limit
Sounder circuit specification
 
Number of general circuits 2
End of line resistor value 6.8k Ω,5% tolerance, 0.25W (colour code-blue,grey,red,gold)
Line fault monitor for open circuit Yes
Line fault monitor for short circuit Yes
Outputs fused AT 400mA
Maximum number of bells @ 20mA of each sounder output 20
Fuses
 
Battery fuse 1.5A F 20mm
Sounder outputs 500mA F 20mm
Fire and fault output
 
Output type NC and NO relay
Maximum current 100mA
Connection block
 
Largest acceptable conductor size 2.5mm2
Smallest acceptable conductor size 0.75mm2
Size and weight
 

 
Dimensions(mm) 272*200*70mm 320*231*90mm 395X502X124 362X565X124
Weight (without batteries) 4kg 5kg 7kg 8kg
Weight (with batteries) 5.8kg 6.8kg 9.6kg 12.5kg
Optional 32-Zone Security Fire Home Alarm System
Optional 32-Zone Security Fire Home Alarm System
 

About the Supplier

This supplier has been audited by CTI. Verify the report on the official CTI website with ID "QIP-ASR242972". Items marked "verified" are certified.

Shenzhen Asenware Test and Control Technology Co., Ltd.
Shenzhen Asenware Test and Control Technology Co., Ltd.
Shenzhen Asenware Test and Control Technology Co., Ltd.
Shenzhen Asenware Test and Control Technology Co., Ltd.
Shenzhen Asenware Test and Control Technology Co., Ltd.
Shenzhen Asenware Test and Control Technology Co., Ltd.
Shenzhen Asenware Test and Control Technology Co., Ltd.
Shenzhen Asenware Test and Control Technology Co., Ltd.

About Our Factory & Business Background

Address
4 / F, 10 Xingye Road, Torch Development Zone, Zhongshan, Guangdong, China
Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment, Money Gram
International Commercial Terms(Incoterms)
FOB, EXW, CIF
Average Lead Time
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays
Nearest Port
Zhongshan

Our Production Capability & Technical Expertise

Main Products
Fire Alarm System, Smoke Detector, Fire Alarm Control Panel, Fire Alarm, FM200, Fire Pump, Flame Detector, Fire Hose Reel, Emergency Light System, Beam Smoke Detector

Our Industry Experience & Global Business Record

Export Year
2005-06-01
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe

FAQ

What is the maximum number of zones supported?
The system supports up to 32 zones, with options for 1, 2, 4-8, and 12-32 zone panels.
Can the zones be customized?
Yes, optional zones range from 1 to 32, with a maximum of 20 detectors per zone.
What are the power supply requirements?
It accepts 110VAC or 240VAC mains supply with a 27.2VDC internal power output.
How many detectors can be connected per zone?
Each zone can support up to 20 smoke or heat detectors based on a total current of 2mA.
Is there a backup battery option?
Yes, it includes a 24VDC backup battery capable of consistently supplying power for 8 hours.
What safety functions does the panel have?
It features low-battery protection, fault monitoring, and buttons for reset, silence, evacuate, and test.
What communication protocols are supported?
The system uses wired cable transmission, with an optional GSM module for SMS alerts.
What are the dimensions of the 32-zone panel?
The 32-zone panel (AW-CFP2166-12-32) measures 362x565x124 mm and weighs 12.5 kg with batteries.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now