Basic Info
  • Model NO.: AW-YT102
  • Signal Transmission: Wired Alarm
  • Application: Indoor, Outdoor
  • Working Principle: Electro-Optical Type
  • Diameter: 4.0 Inch (103 Mm)
  • En Certification: Yes
  • CE Mark: Yes
  • Specification: CE, EN54
  • Type: Smoke Alarm
  • Working Mode: Active
  • Sensor Type: Photoelectric
  • Height: 2.2 Inch (55 Mm) Installed in Base
  • Weight: 5.5 Oz. (155 G)
  • Is09001 Certificate: Yes
  • Trademark: Asenware
  • Origin: Guangdong, China
Product Description
EN and CE Approved Conventional Fire Alarm
Smoke Detector,AW-YT102
En Approved Conventional Fire Alarm Smoke Detector (AW-YT102)
1.GENERAL DESCRIPTION
 The device is photoelectronic detector uses a state of-the-art optical sensing chamber. 
This detector is designed
 to provide open area protection and to be used with most
 conventional fire alarm control panel
.Two LEDs on each detector provide local 360
visible alarm indication. They flash every 5 seconds indicating that power is applied and  
the detector is working properly. The
 LEDs latch on in alarm. LEDs will be off when 
a trouble
 condition exists indicating that the detector sensitivity is outside the listed limit.
The alarm can be reset only by a momentary power interruption.


2.INSTALLATION
En Approved Conventional Fire Alarm Smoke Detector (AW-YT102)
3. Notify the proper authorities that the system is in operation.
En Approved Conventional Fire Alarm Smoke Detector (AW-YT102)

  Operating Voltage Range:          9 to 28 VDC Volts Non-polarized
  Standby Current:                ≤60µA@24VDC
  Maximum Alarm Current (LED on):    ≤30mA@24VDC
  Operating Humidity Range: 10% to 93% Relative Humidity,
 Non- condensing
  Operating Temperature Range:   -10°C to 50°C (14°F to 122°F)
  Smoke Alarm Sensitivity:        0.15-0.3dB/m
  Height:    55 mm installed in Base
  Diameter:    103 mm
  Weight: 5.5 oz. (155 g)