Fire Alarms, Fire Alarm Control Panel, Fire Alarm Panel manufacturer / supplier in China, offering BMS Fire Protection Fire Alarm Host, Aw-D106 Asenware Addressable Alarm Fire Strobe Sounder, Analog Network Fire Alarm Control Panel and so on.

(/ )

Supplier Homepage Product Conventional Fire Alarm System BMS Fire Protection Fire Alarm Host

BMS Fire Protection Fire Alarm Host

FOB Price: Get Latest Price
Min. Order: 1 Piece
Port: Zhongshan, China
Production Capacity: 10, 000PCS/Year
Payment Terms: L/C, T/T, Western Union, Paypal

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: AW-CFP2166-8
  • Signal Transmission: Wired Alarm
  • Certification: SGS, CE, ISO, RoHS, CCC
  • Sensor Type: Electric Alarm
  • Transmission Mode: Cable
  • Receive Frequency: Cable
  • Extendable Zones: 1-32 Zones 20
  • Backup Lead-Acid Battery: 24VDC
  • Individual Zone Capacity: 20 Detectors Max.
  • Housing Material: Metal
  • Alarm Notification: LCD Panel & LED Indicator
  • Trademark: Asenware
  • Specification: Working on LPCB Certificate
  • HS Code: 853110000
  • Type: Industry Alarm
  • Working Mode: Active
  • Application: Indoor, Fire Projects
  • Working Principle: Response to The Trigger Device
  • Alarm Volume (within 1m): ≥110dB
  • Usage: Fire, Smoke, Factory/Hotel/School/Office Fire Alarm Control
  • Power Supply: 240VAC
  • Optional Housing Color: Grey, Red, Black, White
  • Wiring Structure: 2-Wire System
  • Mainboard & Zone Board: SMT Workmanship
  • Package: Seaworthy
  • Transport Package: EPE Inside, Carton Outside
  • Origin: Guangdong, China
Product Description
BMS Fire Protection Fire Alarm Host
BMS Fire Protection Fire Alarm Host


Introductions:
1. Based on EN54 part 2 & 4 standard.
2. Modularized design with flexible following extendable capacity.
3. Two-level control mode by a lock
4.27VDC power supply output.
5. FIRE PROTECTION, FIRE ROUTING and FAULT signal output, the output can be configured to dry relay type or wet sources type.
6.2 channel general sounders output.
7. Each zone has 1 circuit detectors input.
8. Each zone can be disable by a button.
9. RESET button to reset the panel.
10. SILENCE button to stop BUZZER and SOUNDERS.
11. EVACUATE button to start a manual fire alarm immediately.
12. TEST button to test all LEDs orderly.
13. Low-battery level protection with automatic power supply switch function
14. Optional GSM module is available for fire alarm by SMS.

Asenware, professional fire alarm solution provider.
ITEM1Zone panel2Zone panel4-8 Zone panel12-32 Zone panel
Model No.AW-CFP2166-01AW-CFP2166-02AW-CFP2166-04-8AW-CFP2166-12-32
Power specification
 
Mains supply voltage110VAC or 240VAC
Internal power supply27.2VDC
Total output current limited500mA @ 240VAC500mA @ 240VAC3A @ 240VAC3A @ 240VAC
Main supply monitor for faultYes
Battery protection for low voltageYes
Batteries (default configuration)12V2AH*2
Detector circuit specification
 
Number of circuit124-164-32
Line fault monitor for open circuitYes
Line fault monitor for short circuitYes
Line fault monitor for detector removalYes, if End of Line Monitor Unit fitted in place of End of Line Resistor
End of Line device6.8k Ω,5% tolerance, 0.25W (colour code-blue,grey,red,gold)
Detector continuity diodesSilicon 1N4001 or Schottky type (required if End of Line Monitor Unit fitted to give Detector Removal Fault)
Call point resistor value470 to 680 Ω, 0.225 or 0.5 watt
Maximum number of smoke/heat detectors per zone20 (based on a total detector current of 2mA, each detector consuming 100μA).Note: if End of Line Monitor Unit is fitted, for correct operation maxmum voltage drop must not exceed 12 volts.
Maximum number of manual call points per zoneNo limit
Sounder circuit specification
 
Number of general circuits2
End of line resistor value6.8k Ω,5% tolerance, 0.25W (colour code-blue,grey,red,gold)
Line fault monitor for open circuitYes
Line fault monitor for short circuitYes
Outputs fused AT400mA
Maximum number of bells @ 20mA of each sounder output20
Fuses
 
Battery fuse1.5A F 20mm
Sounder outputs500mA F 20mm
Fire and fault output
 
Output typeNC and NO relay
Maximum current100mA
Connection block
 
Largest acceptable conductor size2.5mm2
Smallest acceptable conductor size0.75mm2
Size and weight
 

 
Dimensions(mm)272*200*70mm320*231*90mm395X502X124362X565X124
Weight (without batteries)4kg5kg7kg8kg
Weight (with batteries)5.8kg6.8kg9.6kg12.5kg