• 1-32 Loop 1-32 Zone Conventional Fire Alarm System Control Panel
  • 1-32 Loop 1-32 Zone Conventional Fire Alarm System Control Panel

1-32 Loop 1-32 Zone Conventional Fire Alarm System Control Panel

Type: Industry Alarm
Signal Transmission: Wired Alarm
Working Mode: Active
Application: Indoor
Working Principle: Electro-Acoustic Style
Zones: 1-32
Customization:
Diamond Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
AW-CFP2166-1
Mains Supply Voltage
110VAC/240VAC
Internal Power Supply
27.2VDC
Total Output Current Limited
3A @ 240VAC
Batteries (Default Configuration)
12V2ah*2
Main Supply Monitor for Fault
Yes
Battery Protection for Low Voltage
Yes
Number of Circuit
12V2ah*2
Number of General Circuits
2
Colour
White and Black
Transport Package
EPE Inside, Carton Outside
Specification
CE
Trademark
Asenware
Origin
Guangdong, China
HS Code
8531100000
Production Capacity
100000PCS/Year

Product Description

 1-32 Loop 1-32 Zone Conventional Fire Alarm System Control Panel
1-32 Loop 1-32 Zone Conventional Fire Alarm System Control Panel
1. AW-CFP2166 series conventional fire alarm panel is designed based on EN54 part 2&4 standard.
2. It is modularized design, the panel can expend from 1 zone to 32 zones easily.
3. It has 2 level control mode by a lock
4. It has 24VDC and 5VDC power supply output.
5. It has FIRE and FAULT signal output.
6. It has 2 general sounders output.
7. Each zone has 1 circuit detectors input.
8. Each zone can be disable by a button.
9. It has RESET button to reset the panel.
10. It has SILENCE button to stop BUZZER and SOUNDERS.
11. It has EVACUATE button to start a manual fire alarm immediately.
12. It has battery low protection function, when battery voltage lower than 21VDC, battery will be cut off automatically until the mains power is on.
13. It has an optional GSM module for fire alarm by SMS.
14. It is economic, user-friendly and easy maintenance.

Parameters 
ITEM 1 Zone panel 2 Zone panel 4 Zone panel 8 Zone panel 12-32 Zone panel
Model No. AW-CFP2166-01 AW-CFP2166-02 AW-CFP2166-04 AW-CFP2166-08 AW-CFP2166-12-32
Power specification
Mains supply voltage 110VAC or 220VAC
Internal power supply 27.2VDC
Total output current limited 500mA @ 240VAC 3A @ 220VAC
Main supply monitor for fault Yes
Battery protection for low voltage Yes
Batteries (default configuration) 12V2.3AH*2
Detector circuit specification
Number of circuit 1 2 4 4-8 12-32
Line fault monitor for open circuit Yes
Line fault monitor for short circuit Yes
Line fault monitor for detector removal Yes, if End of Line Monitor Unit fitted in place of End of Line Resistor
End of Line device 6.8k Ω,5% tolerance, 0.5-1W (colour code-blue,grey,red,gold)
Detector continuity diodes Silicon 1N4001 or Schottky type (required if End of Line Monitor Unit fitted to give Detector Removal Fault
Call point resistor value 470 to 680 Ω, 0.5 or 1 watt
Maximum number of smoke/heat
detectors per zone
20 (based on a total detector current of 2mA, each detector consuming 100μA).Note: if End of
Line Monitor Unit is fitted, for correct operation maxmum voltage drop must not exceed 12 volts.
Maximum number of manual call
points per zone
No limit
Sounder circuit specification
Number of general circuits 2
End of line resistor value 6.8k Ω,5% tolerance, 0.5-1W (colour code-blue,grey,red,gold)
Line fault monitor for open circuit Yes
Line fault monitor for short circuit Yes
Outputs fused AT 600mA
Maximum number of bells @ 50mA
of each Sounder output
12 30
Fuses
Battery fuse 1.85A resettable fuse
Sounder outputs 400mA F 20mm 600mA resettable fuse 750mA resettable fuse
Fire output
Output type NC and NO relay
Maximum current 100mA
Connection block
Largest acceptable conductor size 2.5mm2
Smallest acceptable conductor size 0.75mm2
Size and weight
Dimensions(mm) 272X200X70 320X231X90 315*250*90 430X390X140 640X390X150
Weight (with batteries) 5.5kg 7kg 7kg 9kg 13kg

Related products
1-32 Loop 1-32 Zone Conventional Fire Alarm System Control Panel
Our company

Asenware, manufacturer of fire alarm and fire suppression system since 2005. Our headquarter is in London, UK, with factory Shenzhen, China
We keep our best service for our customers, and have a rich experienced engineer team to design and install for overseas projects.

Product range
1. Addressable fire alarm system(FP100 series,2189,2100 series)
2. Conventional fire alarm system(2166 series)
3. FM200 gas fire suppression system
4. Emergency light system
5. Fire pump system
6. Fire hose and fire hose reel cabinet

Our Services
1.OEM / ODM services.
2.Professional technical team.
3.Offer Free technical support whenever you need
4.Two year warranty and technical maintenance

FAQ 
Q1: Are you manufacturer?
A: (yes)
Q2: What is the lead time?
A: usually
Fire control: one week working day
bulk quality: three weeks working days
Emergency lights: two weeks working days
bulk quality: four weeks
FM200:  two weeks working day
Fire pump: 25 days
Q3: How do you ship the goods and how long does it take arrive?
A: We usually ship by DHL, UPS, FedEx or by Air. 3-5 days after payment received.
Q4: Can I have a sample order?
A:Yes,we welcome sample order to test and check quality.
Q5: Do you offer OEM service?
A: Yes, we can design the things according to your request.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Plant Area
>2000 square meters
Management System Certification
ISO 9001