Indoor Fire Security Alarm Sensor Solution System Equipment

Type: Industry Alarm
Signal Transmission: Wired Alarm
Working Mode: Active
Certification: CE, ISO, RoHS, CCC
Application: Indoor, Fire Project
Working Principle: Response to The Trigger Device
Customization:

Contact Supplier

Miss Christine Chen
Sales Director
Diamond Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
AW-CFP2166-2
Transmission Mode
Cable
Alarm Volume (within 1m)
≥100dB
Receive Frequency
Wire
Optional Zone Capacity
1-32
Power Supply
240VAC
Backup Battery
24VDC
Fire Detector
Photoelectric Smoke Detector
Temperature Alarm
Thermal Resistor Heat Detector
Wire System
2-Wire System
Exterior Housing
Weather-Proof Painted Metal Shell
PCB Board Circuit
SMT Process
Optional Panel Color
Red/Grey/Black/White
Warranty & Maintenance
12 Months & Lifetime
Transport Package
Seaworthy Package
Specification
UL/LPCB/CE/Rosh/ISO/SGS
Trademark
Asenware
Origin
Guangdong, China
HS Code
853110000
Production Capacity
10000PCS/Year

Product Description

Indoor Fire Security Alarm Sensor Solution System Equipment
Indoor Fire Security Alarm Sensor Solution System Equipment



Indoor Fire Security Alarm Sensor Solution System Equipment
Key Descriptions:
1. R&D based on EN54 part 2 & 4 standard.
2. Modularized design & flexible extendable capacity.
3. Two-level control mode by a lock
4.27VDC power supply output.
5. FIRE PROTECTION, FIRE ROUTING and FAULT signal output, the output can be configured to dry relay type or wet sources type.
6.2 channel general sounders output.
7. Each zone has 1 circuit detectors input.
8. Each zone can be disable by a button.
9. RESET button to reset the panel.
10. SILENCE button to stop BUZZER and SOUNDERS.
11. EVACUATE button to start a manual fire alarm immediately.
12. TEST button to test all LEDs normally.
13. Low-battery protection function, when battery voltage lower than 21VDC, battery will be cut off automatically until the mains power is on.
14. Optional GSM module is available for fire alarm by SMS.




 
ITEM 1Zone panel 2Zone panel 4-8 Zone panel 12-32 Zone panel
Model No. AW-CFP2166-01 AW-CFP2166-02 AW-CFP2166-04-8 AW-CFP2166-12-32
Power specification
 
Mains supply voltage 110VAC or 240VAC
Internal power supply 27.2VDC
Total output current limited 500mA @ 240VAC 500mA @ 240VAC 3A @ 240VAC 3A @ 240VAC
Main supply monitor for fault Yes
Battery protection for low voltage Yes
Batteries (default configuration) 12V2AH*2
Detector circuit specification
 
Number of circuit 1 2 4-16 4-32
Line fault monitor for open circuit Yes
Line fault monitor for short circuit Yes
Line fault monitor for detector removal Yes, if End of Line Monitor Unit fitted in place of End of Line Resistor
End of Line device 6.8k Ω,5% tolerance, 0.25W (colour code-blue,grey,red,gold)
Detector continuity diodes Silicon 1N4001 or Schottky type (required if End of Line Monitor Unit fitted to give Detector Removal Fault)
Call point resistor value 470 to 680 Ω, 0.225 or 0.5 watt
Maximum number of smoke/heat detectors per zone 20 (based on a total detector current of 2mA, each detector consuming 100μA).Note: if End of Line Monitor Unit is fitted, for correct operation maxmum voltage drop must not exceed 12 volts.
Maximum number of manual call points per zone No limit
Sounder circuit specification
 
Number of general circuits 2
End of line resistor value 6.8k Ω,5% tolerance, 0.25W (colour code-blue,grey,red,gold)
Line fault monitor for open circuit Yes
Line fault monitor for short circuit Yes
Outputs fused AT 400mA
Maximum number of bells @ 20mA of each sounder output 20
Fuses
 
Battery fuse 1.5A F 20mm
Sounder outputs 500mA F 20mm
Fire and fault output
 
Output type NC and NO relay
Maximum current 100mA
Connection block
 
Largest acceptable conductor size 2.5mm2
Smallest acceptable conductor size 0.75mm2
Size and weight
 

 
Dimensions(mm) 272*200*70mm 320*231*90mm 395X502X124 362X565X124
Weight (without batteries) 4kg 5kg 7kg 8kg
Weight (with batteries) 5.8kg 6.8kg 9.6kg 12.5kg
 

Our company

Asenware, manufacturer of fire alarm and fire suppression system since 2005. Our headquarter is in London, UK, with factory Shenzhen, China
We keep our best service for our customers, and have a rich experienced engineer team to design and install for overseas projects.

Indoor Fire Security Alarm Sensor Solution System Equipment

Product range:
1. Addressable fire alarm system(FP100 series,2189,2100 series)
2. Conventional fire alarm system(2166 series)
3. FM200 gas fire suppression system
4. Emergency light system
5. Fire pump system
6. Fire hose and fire hose reel cabinet

Welcome contact

 
mobile:0086-136-3251-2808
 

Send your message to this supplier

*From:
*To:
avatar Miss Christine Chen
*Message:

Enter between 20 to 4,000 characters.