Analog Addressable Fire Alarm Controller

Type: Fire Alarm Host
Function: Networked
Usage: Fire
Certification: CE, ISO, Lpcb
Alarm Volume (within 1m): ≥100dB
Networking Mode: TCP/IP
Samples:
US$ 510/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
AW-FP300
Wiring Mode
Sub-Line System
Product Name
Addressable Fire Alarm Control Panel
Mains Supply
230VAC (-15%, +10%)
Capacity
324 Addresses(Points)
Fire Alarm Output
18.5 ~ 30VDC, 0.5A
Loop Distance
1500m
Certificate
Ce, Lpcb, En54
Operating Voltage
18.5 ~ 30VDC
Sounder Circuit
18.5 ~ 30VDC, 0.5A
Fault Output
30VDC at 2A, 125VAC at 0.5A
Network Communication
RS-485, Can
Transport Package
Carton Box
Specification
57*43.3*18.5
Trademark
Asenware
Origin
China
Production Capacity
5000PCS/Month

Product Description

LPCB Approved Addressable Fire Alarm Control Panel

Analog Addressable Fire Alarm Controller
 

 

Product Description

 

INTRODUCTION


The purpose of the AW-FP300 Fire Alarm Control Panel (FACP) is to monitor input signals, give indications and possibly activate outputs as programmed. It is designed to comply with EN 54-2 & EN 54-4 with qualities of simple installation, operation and easy maintenance.
The AW-FP300 panel is an addressable fire detection panel with 1 loop of 324 addressable points and expansion capabilities. It is compatible with other peripherals made by ASENWARE with its own protocol.
 
PRODUCT FEATURES
1. Up to 324 addresses on one loop
2. An easy to read, 4.3'' color-screen LCD with a resolution of 480×272
3. Zone indication and control panel(ZCP) for 32 zones gives a quick indication of the location of an alarm
4. A record capacity of 1000 historical events for each of historical fire, historical fault and historical operation
5. An independently programmable conventional sounder circuit output
6. Integral power supply and battery
7. Integral printer
8. Flexible and intuitive cause and effect programming on the front panel
9. Zone test, point test, and module start/stop testing facilitate the commissioning
10. U-disk interface makes the load and saves of configuration or historical data convenient for system commissioning and maintenance
11. Hierarchy management with three access levels 
12. Anti-tamper protection by a key lock
13. CAN bus for interconnection of up to 20 FACPs and RS485 for connection with up to 30 fire indicating panels per FACP
 
Parameters

Power Supply

Mains supply  230VAC (-15%, +10%). 47 ~ 63Hz. Max current 0.8A 
Mains fuse  T3.15AL250V 
Operating voltage  18.5 ~ 30VDC 
Recommended mains cable  Screened or standard/black mains cable, cable size 0.75mm2 
Power rating  Imax.a=1.2A; Imax.b=2.6A; Imin=0.65A 
Max. charging current  1.2A 
Max. battery supply current  4A (when the Mains is disconnected) 
Battery capacity, type and recommended model  Max. capacity 2×12V/17Ah; Min. capacity 2×12V/12Ah 
VRLA. PS-12170 for 17Ah (Power-sonic), PS12120 for 12Ah (Power-sonic) 
Max. internal resistance of battery  1.5Ω
Battery fuse  F8AL250V 
Recommended battery cable  14AWG 
Quiescent current (full loaded)  < 0.4A 

 

 Outputs

S.C. Out (+, -)  Output voltage  18.5 ~ 30VDC
Max. output current  0.5A 
Fuse rating  F1AL250V 
End of line resistor  4K7 
Recommended type of cable  Plain unscreened cable, 1.5mm2 
Cable diameter  1mm2 ~2mm2 
Transmission distance  ≤1500m 
Max. number of sounders @50mA  20

F.P.E. Out (+, -) 

F.A. Out (+, -) 

Output voltage  18.5 ~ 30VDC
Max. output current  0.5A 
Fuse rating  F1AL250V 
End of line resistor  4K7 
Recommended type of cable Plain unscreened cable,1.5mm2 
Cable diameter  1mm2 ~2mm2 
Transmission distance  ≤1500m 

Fault Out 

(NC, COM, NO) 

Contact capacity  30VDC at 2A, 125VAC at 0.5A
Recommended type of cable  Plain unscreened cable,1.5mm2 
Cable diameter  1mm2 ~ 2mm2 
24VK (+, -)  Output voltage  18.5 ~ 30VDC 
Max. output current  0.6A 
Fuse rating  F1AL250V 
Recommended type of cable Plain unscreened cable,1.5mm2 
Cable diameter  1mm2 ~2mm2 

 

 Input

Class change (+, -)  Input mode  Passive 
Cable resistance  ≤500Ω
Recommended type of cable  Plain unscreened cable, 1.5mm2 
Cable diameter  1mm2 ~2mm2 

 

 Loop

Loop Out (+, -)

Loop In (+, -

Output voltage  16.5 ~ 30VDC, pulse 
Output current  0 ~0.3A 
Loop type  Class A 
Recommended type of cable  Screened or unscreened twisted-pair, 1.5mm2 
Transmission distance  ≤1000m 
Cable diameter  1mm2 ~2mm2 

 

 Network Communication

 

RS-485  Max. number of FIPs  30 
Transmission rate  9600 bps 
Recommended type of cable  Screened or unscreened twisted-pair, 1mm2 
Transmission distance  ≤1000m 
Cable diameter  1mm2 ~5mm2 
CAN  Max. number of panels  20 
Transmission rate  Optional: 10K, 20K, 50K and 100K bps 
Recommended type of cable  Screened or unscreened twisted-pair, 1mm2 
Transmission distance  ≤1000m 
Cable diameter  1mm2 ~5mm2 

Related Products

     Analog Addressable Fire Alarm Controller
Analog Addressable Fire Alarm Controller
Analog Addressable Fire Alarm Controller
Analog Addressable Fire Alarm Controller
Analog Addressable Fire Alarm Controller
Analog Addressable Fire Alarm Controller

TRANSPORTATION
Analog Addressable Fire Alarm Controller


Certifications

Analog Addressable Fire Alarm Controller
 

 


FAQ

Q1: How about the quality of the products?
A: We produce every product with good quality materials, and test carefully to make sure stable quality before shipment.

Q2: Can I have a sample order?
B: Yes, Of course you can . we welcome sample order for your testing and checking products quality.Mixed samples are avaliable.

Q3: What is the shipping time?
C: Small Qty order needs 3-5 working days, big Qty order usually needs 10-5 working days after
payments arriving. That's depends on order Qty.

Q4: How to proceed the order if I have logo to print?
D: We will prepare artwork for visual confirmation at first, if the color and position are alright,we
will make print Logo sample from silk print factory and take picture for you to comfire before mass production.


Company Information

ASENWARE LTD

We are manufacturer of fire alarm and fire suppression system since 2005, our headquarter is in London,UK, with factory Shenzhen China and Zhongshan factory.

We keep our best service for our customers and have a rich experienced engineer team to design and install for overseas projects.

We are professional do fire alarm products about 15 years in China. Our fire safety products, solutions, and services are used in over 100 countries.
 

Product range:
1. Addressable fire alarm system
2. Conventional fire alarm system
3. FM200 gas fire suppression system
4. Emergency light system
5. Fire pump system
6. Fire hose and fire hose reel cabinet

Analog Addressable Fire Alarm Controller
Analog Addressable Fire Alarm Controller

CONTACT INFORMATION

Contact:Iris Huang
 
 
 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Plant Area
>2000 square meters
Management System Certification
ISO 9001