Conventional Fire Alarm Heat Detector in Rate to Rise and Fixed Temperature Type

Type: Temperature Sensor Probe
Anti-theft Alarm System Approach: Active
Anti-Theft Alarm System Type: Smoke Alarms
Anti-Theft Alarm System-Wide: Wire Alarm Detectors
Anti-Theft Alarm System Distance: Common Detectors
Types of Smoke Detectors: Photoelectric Smoke Style
Customization:
Diamond Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
AW-CTD382
Infrared Sensor Probe Type
Infrared Temperature Sensor
Infrared Sensor Installation
Ceiling
Diameter
99.45mm
Rate of Rise Alarm
7.1c/5s
Fix Temperature Alarm
57c
Transport Package
Carton Packing
Specification
Height: 48.2mm installed
Trademark
Asenware
Origin
China
Production Capacity
100, 000

Product Description

LPCB Conventional fire alarm heat detector 

Model: AW-CTD382

 

Product Description

 AW-CTD382 is conventional photo-electronic smoke detector uses a state of-the-art optical sensing chamber. This detector is designed to provide open area protection and to be used with most
conventional fire alarm panel. 
The conventional rate of rise heat detector uses thermal component to detect the temperature changing in the environment. It can enable fire alarm when the temperature difference achieved the setting rate of rise temperature value. It can also enable fire alarm when the absolute temperature value reach the setting fixed value. It has a stable and reliable working performance.
Two LEDs on each detector provide local 360° visible alarm indication. They flash every six seconds indicating that power is applied and the detector is working properly. The LEDs latch on in alarm. LEDs will be off when a trouble condition exists indicating that the detector sensitivity is outside the listed limit. The alarm can be reset only by a momentary power interruption.
The detector that initiated the alarm condition will have its red LED and relays latched until rest by panel.

Conventional Fire Alarm Heat Detector in Rate to Rise and Fixed Temperature Type

Conventional Fire Alarm Heat Detector in Rate to Rise and Fixed Temperature Type
Conventional Fire Alarm Heat Detector in Rate to Rise and Fixed Temperature Type




Features

Operating Voltage Range:                                     9 to 28VDC Non-polarized
Standby Current:                                                    ≤120uA @ 24VDC
Maximum Alarm Current ( LED on):                       ≤15mA @ 24VDC
                                                                               ( 1K Ohm current-limiting resistance)  
Operating Humidity Range:                                    ≤ 95% RH ( 40ºC± 2ºC)
                                                                               Relative Humidity, Non-condensing  
Operating Temperature Range:                              -10ºC to 50ºC (14ºF to 122ºF)
Fix Temperature Alarm:                                          57ºC(135ºF)A2R
Rate of rise Alarm:                                                 7.1ºC/5S A2R
Height:                                                                   48.2mm installed in Base
Diameter:                                                               99.45mm
Standard Number ref:                                            EN 54-7:2000    
EC certificate:                                                        0832-CPR-F2072       

Parameters

Conventional Fire Alarm Heat Detector in Rate to Rise and Fixed Temperature Type
 

 

Company Information

Asenware, is the fire alarm system and fire suppression system manufacturer and whole fire safety solution provider since 2005

Driven by a commitment to sound operations, ongoing innovation, and open collaboration, we have established a competitive fire safety products line include addressable fire alarm system, conventional fire alarm system, central monitoring emergency light system, fire telephone and emergency audio systemm, fire pump, fire hose and gas suppression system.

Our fire safety products, solutions and services are used in over 100 countries.

With over 200 employees work in United Kingdom-Marketing center, China-R&D and Supply Chain center and Bangladesh-Manufacture center, Asenware is committed to design and manufacturer the best fire safety products to reduce the risk of fire, and support the world to be more safe and more comfortable.

Product range

Addressable fire alarm system
Conventional fire alarm system (2166 series)
FM200 gas suppression system (2159 series)
Fire pump
Fire hose/ hose reel and cabinet
ABC powder/ CO2 fire extinguisher
Emergency light system

Conventional Fire Alarm Heat Detector in Rate to Rise and Fixed Temperature Type


Certificates

Conventional Fire Alarm Heat Detector in Rate to Rise and Fixed Temperature Type

 

Our Services

Ø OEM & ODM service: YES

Ø Technical support and After-sale service: YES

Ø Warranty: 1 YEAR

Ø Delivery Time: 3 - 5 days after payment received

Ø Shipping: delivery by air, ship or DHL, FEDX etc. Express for your order

 

Name Card

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Plant Area
>2000 square meters
Management System Certification
ISO 9001