Asenware Lpcb Approved Conventional Fire Detection System Control Panel Aw-2166

Type: Fire Alarm
Anti-theft Alarm System Approach: Active
Anti-Theft Alarm System Type: Sound and Light Alarm
Anti-Theft Alarm System-Wide: Point Control Alarm Detectors
Anti-Theft Alarm System Distance: Power Detector
Types of Smoke Detectors: Photoelectric Smoke Style
Customization:
Diamond Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
AW-2166
Infrared Sensor Probe Type
Inclination Sensor
Infrared Sensor Installation
Ceiling
Combustible Gas Detector Model
Smoke
Item
Conventional Fire Alarm Control Panel
Brand
Asenware
Fob Port
Shenzhen
Delivery Time
5-8 Days
Manufacturer
Yes
Feature
Addressble
Color
Red or as Customized
Model
Aw-2166
Payment
T/T, Western Union
Package
as Customized
Transport Package
as Customized
Specification
0.026
Trademark
Asenware
Origin
China
Production Capacity
10000 PCS

Product Description

Asenware LPCB Approved Conventional Fire Detection System Control Panel AW-2166
 

1.         AW-CFP2166 series conventional fire alarm panel is designed based on EN54 part 2&4 standard.

2.         It is modularized design, the panel can extend from 1 zone to 32 zones easily.

3.         It has 2 level control mode by a lock

4.         It has 24VDC and 5VDC power supply output.

5.         It has FIRE and FAULT signal output.

6.         It has 2 general sounders output.

7.         Each zone has 1 circuit detectors input .

8.         Each zone can be disable by a button.

9.         It has RESET button to reset the panel.

10.     It has SILENCE button to stop BUZZER and SOUNDERS.

11.     It has EVACUATE button to start a manual fire alarm immediately.

12.     It has battery low protection function, when battery voltage lower than 21VDC, battery will be cut off automatically until the mains power is on.

13.     It has an optional GSM module for fire alarm by SMS .

14.     It is economic, user-friendly and easy maintenance.

 

ITEM 1Zone panel 2Zone panel 4-8 Zone panel 12-32 Zone panel
Model No. AW-CFP2166-01 AW-CFP2166-02 AW-CFP2166-04-8 AW-CFP2166-12-32
Power specification  
Mains supply voltage 110VAC or 240VAC
Internal power supply 27.2VDC
Total output current limited 500mA @ 240VAC 500mA @ 240VAC 3A @ 240VAC 3A @ 240VAC
Main supply monitor for fault Yes
Battery protection for low voltage Yes
Batteries (default configuration) 12V2AH*2
Detector circuit specification  
Number of circuit 1 2 4-16 4-32
Line fault monitor for open circuit Yes
Line fault monitor for short circuit Yes
Line fault monitor for detector removal Yes, if End of Line Monitor Unit fitted in place of End of Line Resistor
End of Line device 6.8k Ω,5% tolerance, 0.25W (colour code-blue,grey,red,gold)
Detector continuity diodes Silicon 1N4001 or Schottky type (required if End of Line Monitor Unit fitted to give Detector Removal Fault)
Call point resistor value 470 to 680 Ω, 0.225 or 0.5 watt
Maximum number of smoke/heat detectors per zone 20 (based on a total detector current of 2mA, each detector consuming 100μA).Note: if End of Line Monitor Unit is fitted, for correct operation maxmum voltage drop must not exceed 12 volts.
Maximum number of manual call points per zone No limit
Sounder circuit specification  
Number of general circuits 2
End of line resistor value 6.8k Ω,5% tolerance, 0.25W (colour code-blue,grey,red,gold)
Line fault monitor for open circuit Yes
Line fault monitor for short circuit Yes
Outputs fused AT 400mA
Maximum number of bells @ 20mA of each sounder output 20
Fuses  
Battery fuse 1.5A F 20mm
Sounder outputs 500mA F 20mm
Fire and fault output  
Output type NC and NO relay
Maximum current 100mA
Connection block  
Largest acceptable conductor size 2.5mm2
Smallest acceptable conductor size 0.75mm2
Size and weight    
Dimensions(mm) 272*200*70mm 320*231*90mm 395X502X124 362X565X124
Weight (without batteries) 4kg 5kg 7kg 8kg
Weight (with batteries) 5.8kg 6.8kg 9.6kg 12.5kg
Asenware Lpcb Approved Conventional Fire Detection System Control Panel Aw-2166

Asenware Lpcb Approved Conventional Fire Detection System Control Panel Aw-2166
Asenware Lpcb Approved Conventional Fire Detection System Control Panel Aw-2166
Asenware Lpcb Approved Conventional Fire Detection System Control Panel Aw-2166
Asenware Lpcb Approved Conventional Fire Detection System Control Panel Aw-2166



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.